background image

DVB to IP streamer STI520 

EN 

 

Vers. 1.01 

 

 

1. Product description 

This is a dual tuner local TV (DVB-T/T2/C) to IP gateway for home users. The device allows multiple users to 

watch local TV on their smartphone, tablet, smart TV or personal computer. The device also allows video 

recording to the USB or local network drive for watching the records later. It is possible to access the device from 

outside your local network (e.g. using the smartphone and mobile data connection) and watch TV and records 

remotely. 

“TerraTV” Android app is designed specifically for this product for video playback. Third-party video players 

are supported as well. 

STI520P is packed with an external power supply. 

The device is intended for indoor usage only. 

2. Safety instructions 

The streamer is powered from the external power 12 V. This voltage is not dangerous to life. 

Any repairs must be done by the skilled personnel. 

Do not plug the power supply of the streamer into the mains until all the cables have been connected 

correctly. 

Streamer shall not be exposed to dripping or splashing water. 

Avoid placing the streamer next to central heating components, near highly combustible materials and in 

areas of high humidity. 

If the streamer has been kept in cold conditions for a long time, keep it in a warm room no less than 2 hours 

before use. 

Do not place the streamer on unstable surfaces, where the unit may fall and resulting possible damage. 

Do not insert any objects into the ventilation openings. 

The ventilation should not be impeded by covering the streamer with items, such as newspapers, cloths, 

curtains. 

 

Scan for  downloading TerraTV app 

from Google Play

 

 

 

 

 

 

This product complies with the relevant clauses of the European Directive 2002/96/EC. The unit must 

be recycled

 

or discarded according to applicable local and national regulations.

 

 

Equipment intended for indoor usage only.

 

 

This product is in accordance to following norms of EU: EMC norm EN50083-2, safety norm 

EN62368-1 and

 

RoHS norm EN50581. 

 

This product is in accordance with Custom Union Technical Regulations: “Electromagnetic 

compatibility of technical

 

equipment“ CU TR 020/2011, “On safety of low-voltage equipment“ CU TR 

004/2011 

 

This product is in accordance with safety standard AS/NZS 60065 and EMC standards of Australia. 

Summary of Contents for STI520

Page 1: ... exposed to dripping or splashing water Avoid placing the streamer next to central heating components near highly combustible materials and in areas of high humidity If the streamer has been kept in cold conditions for a long time keep it in a warm room no less than 2 hours before use Do not place the streamer on unstable surfaces where the unit may fall and resulting possible damage Do not insert...

Page 2: ...r or personal computer Connect device power supply to the device DC IN connection 5 and plug the power supply to the mains 4 1 WEB browser requirements Streamer supports the following WEB browsers Chrome starting from version 66 Opera starting from version 53 Safari starting from version 12 1 Firefox starting from version 53 Edge starting from version 80 Internet Explorer is not supported 4 2 Requ...

Page 3: ... to the personal computer as described in the section 4 3 2 4 3 2 Accessing the device when connected directly to the personal computer When device is connected directly to the personal computer or if there is no DHCP server in the network the default IP address of streamer is 192 168 1 10 Ensure that subnet 192 168 1 0 is accessible from your computer If you are not sure please read troubleshooti...

Page 4: ... there is a problem with the connection the line is shown in red color and the notification text describing the problem is displayed in the diagnostics information window Depending on the device setup some connections may not be displayed For example if no storage location is specified neither the USB nor the network drive will be displayed The list on the right side shows the video stream viewers...

Page 5: ...e the TV programs and radio stations names Status column shows the RF signal quality bars icon You can also hover on the status bars icon to see detailed signal parameters such as signal to noise ratio SNR and RF channel level values Device continuously monitors each RF channel s signal parameters Depending on the modulation standard you can also see signal parameters such as bandwidth symbol rate...

Page 6: ... choose the file from your computer GIF PNG JPG formats are supported or may enter a WEB link where the picture exists HTTP or HTTPS protocols are supported for downloading the picture from WEB links Make sure the device can connect to the Internet Figure 8 Channel logo assigning pop up 2 Open a page with logo images in one browser window In the next browser window open the device TV channels sett...

Page 7: ...ls into user defined groups M3U playlist format supports linear groups only while DLNA supports up to three levels grouping M3U playlist entries grouping must be supported by the video player that you are using Otherwise this function will not work Edit channel groups add or modify existing channels groups Click on the icon to edit See section 5 4 2 for more information Click on the Update button ...

Page 8: ...playlist link with an external IP address in the next configuration interface table as shown in Figure 13 Make sure your router is set up properly to access the playlist and video stream If your router supports UPnP remote access can be managed as described in the section 5 6 2 NOTE if you make changes in the playlist configuration window you also must download the updated playlist file and import...

Page 9: ...e One time recording means a single recording at the exact time and specified duration The start time can be selected up to 6 days in advance Such schedule entry is shown in Figure 15 Polsat record If One time recording checkbox is selected the checkboxes indicating the days of the week will be ignored Weekly recording means that the TV channel will be recorded on each selected day of the week at ...

Page 10: ...ch domain names and is only available on the local network There are two domain names used to help you accessing the device WEB control interface Unique local network DNS entry is unique device domain name in the local network You can access the device using this unique address entry even if there are multiple steamers in the same network Use the following domain name http serial local Where seria...

Page 11: ...to access the device remotely http external_IP_adress external_WEB_port When you click the Update the device will try to enable disable the selected ports on network router The status indicator icons will show the progress of the operation Hovering over the status icon will display more status information 5 6 3 HTTPS The user interface of the device can be accessed via the secure HTTPS protocol Re...

Page 12: ...arnings will be displayed the system log see Figure 20 Each record has its own type that can be used to filter only certain messages Figure 20 Logs filtering Just check the Logs filtering checkboxes Messages will be filtered automatically The Erase logs button will delete all logs from the system The Download button creates a logs json file that can be used for troubleshooting and receiving help f...

Page 13: ...lso create a backup of your current settings and save to a file Click the submenu item Export settings and select the file path where the settings should be saved If you have multiple devices it is recommended to rename the exported file and give a clear description to file name 5 7 5 Import parameters Exported settings can be imported from one device to another or to the same device Device type m...

Page 14: ...pload button to upload the file to your device A confirmation message will appears on the screen asking you to reboot the device Do not disconnect the power supply from the device during programming The login window will appear on the screen as soon as the firmware update is completed No need to refresh the browser All device settings will remain unchanged 5 7 7 Restart device The device can be re...

Page 15: ...ncorrect 5 7 11 Date time It s important that the device has the correct time selected Recording schedules is affected by the system time Figure 30 shows the two NTP servers as a date time source Figure 30 Date and time settings Local Time shows the time of the device that it currently has estimating possible DST offset If the time in this field is not correct make sure you select the correct coun...

Page 16: ...fault values and application will be restarted IP settings will not be restored to defaults Restore firmware to factory version This command is intended for use in critical situations where it is not possible to use other recovery method The command will delete all files from the device and restore the original application from read only memory All firmware upgrades will be lost so you will need t...

Page 17: ...luding recordings supported protocol DLNA HTTP SRT number of users 4 MPTS No SPTS Yes Control port standard IEE802 3 10 100 Base T Current consumption without external load 12 1 V 300 mA STI520 Current consumption with max external load 12 1 V 700 mA STI520 Supply voltage limit values power consumption 100 240 V 50 60 Hz 10 W max STI520P Operating temperature 0º C 50º C Dimensions Weight packed 11...

Reviews: