Isys
®
8.4” WiFi Touch Screen
Crestron
TPMC-8X-GA
Charging the Internal Battery
NOTE:
A Lithium Ion (Li-Ion) battery typically provides 300-500 charge/discharge
cycles.
There are three ways to charge the TPMC-8X-BTP Internal Battery Pack:
•
With the TPMC-8X-BTP installed in the TPMC-8X-GA touch screen,
connect the touch screen to an AC source using its AC adapter or
•
With the TPMC-8X-BTP installed in the TPMC-8X-GA touch screen,
mount the touch screen on an AC powered TPMC-8X-DS Docking
Station/Charger (sold separately) or
•
With the TPMC-8X-BTP installed in the TPMC-8X-GA touch screen,
mount the touch screen on a TPMC-8X-DSW Wall Mount Docking
Station/Charger (sold separately).
NOTE:
The battery pack may take up to three hours to charge in a powered touch
screen if the touch screen is in use during charging.
NOTE:
When the external battery pack (TPMC-8X-BTPE, sold separately) is
attached, both the internal and external battery packs charge simultaneously.
Security Infrastructure
Since the TPMC-8X-GA does not use a traditional hard drive but rather an image
that gets restored every time the touch screen is rebooted, any virus infection is
cleared immediately after a reboot. However, using the currently available tools and
techniques, Crestron has provided an infrastructure that protects against possible
virus infections.
1. Executables/Scripts brought in on external media
The implementation of the TPMC-8X-GA has restrictions on starting any
application or script. The only applications that can be started are those allowed
by Crestron and these can only be started from the Crestron project.
2. Downloaded
Program/Script
The browser is customized in such a way that files cannot be downloaded. The
only files the browser can open are the files it has plug-ins for, such as PDF, etc.
The user cannot change the options, as this dialog box has been disabled.
3. Browser Hijack and Browser vulnerability
Crestron has patched all currently known hijacks and vulnerabilities. Future
updates can be downloaded from the Crestron Web site.
4. Email
Viruses
There is no e-mail client installed on the TPMC-8X-GA, so email-based viruses
cannot be executed.
5. Viruses that attack Web/FTP servers
The TPMC-8X-GA does not run a Web or FTP server and is therefore not
listening to port 21 or 80. The only ports the system listens to are the ports
registered to Crestron.
6. Virus from other machines on the network
Since drives on the TPMC-8X-GA can be shared on the network, it is possible
that a virus can write itself to files/folders on these shares. Our recommendation
50
•