background image

Dual AC Power Control Module

 

Crestron

 ST-PC 

 Return and Warranty Policies 

Merchandise Returns / Repair Service 

1.  No merchandise may be returned for credit, exchange, or service without prior authorization 

from CRESTRON. To obtain warranty service for CRESTRON products, contact the factory 
and request an RMA (Return Merchandise Authorization) number. Enclose a note specifying 
the nature of the problem, name and phone number of contact person, RMA number, and 
return address. 

2.  Products may be returned for credit, exchange, or service with a CRESTRON Return 

Merchandise Authorization (RMA) number. Authorized returns must be shipped freight 
prepaid to CRESTRON, 6 Volvo Drive, Rockleigh, N.J., or its authorized subsidiaries, with 
RMA number clearly marked on the outside of all cartons. Shipments arriving freight collect 
or without an RMA number shall be subject to refusal. CRESTRON reserves the right in its 
sole and absolute discretion to charge a 15% restocking fee, plus shipping costs, on any 
products returned with an RMA. 

3.  Return freight charges following repair of items under warranty shall be paid by 

CRESTRON, shipping by standard ground carrier. In the event repairs are found to be non-
warranty, return freight costs shall be paid by the purchaser. 

CRESTRON Limited Warranty 

CRESTRON ELECTRONICS, Inc. warrants its products to be free from manufacturing defects in materials and 
workmanship under normal use for a period of three (3) years from the date of purchase from CRESTRON, 
with the following exceptions: disk drives and any other moving or rotating mechanical parts, pan/tilt heads and 
power supplies are covered for a period of one (1) year; touchscreen display and overlay components are 
covered for 90 days; batteries and incandescent lamps are not covered.  

This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer. 
Purchasers should inquire of the dealer regarding the nature and extent of the dealer's warranty, if any. 

CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any 
application other than that for which it was intended, or if it has been subjected to misuse, accidental damage, 
modification, or improper installation procedures. Furthermore, this warranty does not cover any product that 
has had the serial number altered, defaced, or removed.  

This warranty shall be the sole and exclusive remedy to the original purchaser. In no event shall CRESTRON 
be liable for incidental or consequential damages of any kind (property or economic damages inclusive) arising 
from the sale or use of this equipment. CRESTRON is not liable for any claim made by a third party or made by 
the purchaser for a third party.  

CRESTRON shall, at its option, repair or replace any product found defective, without charge for parts or 
labor. Repaired or replaced equipment and parts supplied under this warranty shall be covered only by the 
unexpired portion of the warranty. 

Except as expressly set forth in this warranty, CRESTRON makes no other warranties, expressed or implied, 
nor authorizes any other party to offer any warranty, including any implied warranties of merchantability or 
fitness for a particular purpose. Any implied warranties that may be imposed by law are limited to the terms of 
this limited warranty. This warranty statement supercedes all previous warranties. 

 

Trademark Information

 

All brand names, product names, and trademarks are the sole property of their respective owners. Windows is a registered trademark of 
Microsoft Corporation. Windows95/98/Me/XP and WindowsNT/2000 are trademarks of Microsoft Corporation. 

 

18  

  Dual AC Power Control Module: ST-PC Operations 

Guide – DOC. 5708A 

Содержание ST-PC

Страница 1: ...Crestron ST PC Dual AC Power Control Module Operations Guide ...

Страница 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2003 Crestron Electronics Inc ...

Страница 3: ...ookup 7 Programming Software 9 Earliest Version Software Requirements for the PC 9 Programming with SIMPL Windows 9 Uploading 12 Communication Settings 13 Uploading a SIMPL Windows Program 15 Problem Solving 16 Troubleshooting 16 Further Inquiries 17 Future Updates 17 Return and Warranty Policies 18 Merchandise Returns Repair Service 18 CRESTRON Limited Warranty 18 Operations Guide DOC 5708A Conte...

Страница 4: ......

Страница 5: ...ad sockets A and B of 10 Amp maximum 6 Amp maximum for the STI PC There are several unique features of the ST PC Two momentary pushbutton switches on the front panel of the unit can be programmed to toggle the relays via the control system The pushbutton switches locally toggle a relay when the control system is inactive During network activity the relays assume the state dictated by the control s...

Страница 6: ...Connectors NET POWER A Two 6 pin RJ type connectors One 3 pin AC connector ST PC One 3 conductor six foot cable STI PC POWER B One 3 pin AC connector ST PC One 3 conductor six foot cable STI PC 12 VDC 0 5A One Male receptacle for external power pack POWER IN One 3 conductor cable Rack Space 1 unit high unit wide Environmental Temperature 41 to 113 F 5 to 45 C Environmental Humidity 10 to 90 RH non...

Страница 7: ...anels There are four LEDs on the front panel that indicate the unit s current status There are also two momentary pushbutton switches that are used to toggle the relay states The two switches are located to the right of the POWER A B LEDs on the front panel All connections are made on the back of the unit The proper domestic and international power cords and plugs are used on the ST PC and STI PC ...

Страница 8: ... INC N J 07626 POWER A POWER IN 120 220VAC 10A MAX OUTPUT COMBINED 50 60HZ POWER B CRESTRON STI PC Physical Views STI PC PWR A C CONTROLLER NET POWER B POWER A 1 70 in 4 32 cm 7 07 in 17 96 cm CRESTRON CRESTRON 6 13 in 15 57 cm 6 32 in 16 05 cm 6 94 in 17 63 cm 1 50 in 3 81 cm NET NET 5A 12VDC CRESTRON ELECTRONICS INC N J 07626 POWER A POWER IN 125 VAC 10A MAX OUTPUT COMBINED 50 60HZ POWER B 4 Dua...

Страница 9: ...module to a Cresnet control system When the module is part of the Cresnet system power may be supplied via NET if within system power and cable length limits the supplied power pack is optional and need not be attached Two NET ports are available so that network units can be daisy chained together Review the latest revision of the Network Modular Cable Requirements Doc 5682 Net Connectors PIN SIGN...

Страница 10: ...network ID as the ST PC POWER A This LED illuminates when the unit plugged into the POWER A three prong socket connector at the back panel is on relay is engaged A momentary pushbutton switch toggles the A relay between its two states when the control system is inactive When the control system is active the LED is under program control and must have its functionality programmed Refer to ST PC Symb...

Страница 11: ...is the only unit connected to the control system 2 Open the Crestron Viewport 3 From the Viewport menu select Functions Set Network ID The software checks the baud rate and then opens the Set Network ID window 4 In the Set Network ID window select the device requiring a Net ID change from the Current Network Devices text window 5 Select the new Net ID for the device from the Choose the new network...

Страница 12: ...O AC OUTLET DEVICE REQUIRING AC POWER CONTROL POWER A POWER IN POWER B 50 60HZ 10A MAX OUTPUT COMBINED 90 125VAC Cresnet NOTE USE ST CNB SOLD SEPARATELY TO CONNECT ST PC TO CRESNET DEVICE REQUIRING AC POWER CONTROL Hookup Connections for STI PC OPTIONAL POWER PACK 1000 mA NET G 24 Z Y CRESTRON ELECTRONICS INC N J 07626 5A 12VDC POWER B DAISY CHAIN TO ADDITIONAL NETWORK DEVICES NET NET POWER A PLUG...

Страница 13: ... Crestron Viewport version 3 35 or later Programming with SIMPL Windows NOTE The following assumes that the reader has knowledge of SIMPL Windows If not refer to the extensive help information provided with the software NOTE The following are file extensions for programs that include an ST PC developed for specific control system types smw source file spz compiled file for 2 series bin compiled fi...

Страница 14: ...c This tree can be expanded to display and configure the communication ports Expanded PRO2 System Tree C2Net Device Slot in Configuration Manager To incorporate an ST PC into the system drag the ST PC from the Cresnet Control Modules Cresnet Power Control Modules folder of the Device Library and drop it in System Views The PRO2 system tree displays the ST PC in Slot 9 with a default Net ID of 2C a...

Страница 15: ...he Net ID as shown in the following figure ST PC Device Settings Window NOTE SIMPL Windows automatically changes the Net ID values of a device added to a program if a duplicate device or a device with the same default Net ID already exists in the program Always ensure that the hardware and software settings of the Net ID match For Net ID hardware setting details refer to Identity Code on page 7 Op...

Страница 16: ...stems they are not available with the ST CP or CN Series control systems To add a device extender right click the ST PC in Program View point to Insert Device Extender and select the desired device extender To program a device extender expand the ST PC in Program View and drag the device extender to Detail View Uploading Assuming a PC is properly connected to the entire system Crestron programming...

Страница 17: ...d Crestron has tested the following devices with good results Belkin large model F5U103 I O Gear GUC232A Keyspan USA 19QW Other models even from the same manufacturer may not yield the same results The procedure in this section provides details for RS 232 communication between the PC and the control system If TCP IP communication is preferred consult the latest version of the Crestron e Control Re...

Страница 18: ...alternatively press Alt D to open the Port Settings window Setup Communications Settings Command 3 Select RS 232 as the connection type Verify that an available COM port COM 1 is shown after this step is selected and that all communication parameters and necessary options from the Port Settings window are selected as shown after this step Click the OK button to save the settings and close the wind...

Страница 19: ...s 1 Start SIMPL Windows 2 Select File Open to view the Open window navigate to the SIMPL Window file smw and click Open 3 Select Project Transfer Program Upload via Crestron Viewport 1 Verify that the procedure for Communication Settings that begins on page 13 has been performed 2 As shown after this step select File Transfer Send Program Alternatively press Alt P from the Viewport menu File trans...

Страница 20: ...stem Network devices are not communicating to the control system From the Viewport poll the network F4 to verify communication ST PC is not receiving power Confirm that power pack securely plugged into outlet and that the connector is properly attached to the ST PC Verify that proper cables are securely attached to ST PC NET connectors for Cresnet system only Green PWR LED does not illuminate Inco...

Страница 21: ...e online help section of the Crestron website www crestron com to ask questions about Crestron products First time users will need to establish a user account to fully benefit from all available features Future Updates As Crestron improves functions adds new features and extends the capabilities of the ST PC additional information may be made available as manual updates These updates are solely el...

Страница 22: ...nt lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has bee...

Страница 23: ...Crestron ST PC Dual AC Power Control Module Operations Guide DOC 5708A Dual AC Power Control Module ST PC 19 This page intentionally left blank ...

Страница 24: ...Crestron Electronics Inc Operations Guide DOC 5708A 15 Volvo Drive Rockleigh NJ 07647 11 03 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Отзывы: