Crestron
ST-IO
Input/Output Module
NOTE:
The new Net ID code may also be verified by selecting
Diagnostic | Report
Network Devices
in the Viewport (alternately, select
F4
).
10. Repeat this procedure for each additional network device requiring a Net ID
change.
Digital Input Modes
All four digital inputs on the ST-IO are factory set in the closure mode. However,
any number of inputs can be changed to voltage mode by opening the unit and
moving a jumper over the proper pins. Verify the current setting of each digital input
using Viewport to poll the network devices. From the Viewport main menu, select
Diagnostics | Report Network Devices
, or press
F4
. A detailed list of all devices
will be displayed. The data includes the Net ID, the name and type of device, as well
as its operating system or firmware version and configuration data, where applicable.
A factory supplied unit responds with the following configuration data.
INPUT MODE: IN1=C, IN2=C, IN3=C, IN4=C
Each input (IN1 through IN4) is in closure mode (C). Voltage mode is defined with
a “V”.
If the mode setting for any of the digital inputs must be changed, power down the
ST-IO and complete the following steps.
1. Turn the unit over and place it topside down on a soft, clean surface.
2. Loosen and remove four screws and washers that secure the top cover to the
ST-IO.
3. Lift, turn the unit over, and place the unit down on its four rubber feet.
4. Slide the top cover toward the back panel while holding the ST-IO in place
until the cover is free.
5. Locate the jumpers covering pins for the respective inputs (labeled 1, 2, 3,
and 4 from right to left). Refer to the following illustration.