Crestron
QM-RMCRX-BA
QuickMedia™ Receiver/Processor
COM Port Signals (continued)
SIGNAL TYPE
AND NAME
DESCRIPTION
Digital input
<
RESERVED
>
Not implemented - reserved for future.
Optional digital input
<
dtr
>
Activates the DTR (Data Terminal Ready) pin on the COM port for as long as the
input is high.
High/1 (level sensitive) = Activate DTR pin
Low/0 = Release DTR pin
Optional digital output
<
dsr
>
Indicates that the DSR (Data Set Ready) pin on the COM port has been activated.
The output remains high for as long as the DSR pin is activated.
High/1 = DSR pin activated
Low/0 = DSR pin released
Parameters
<
str1
> <
str2
>
Defines a string literal that will be transmitted out of the COM port.
Optional parameter
<
delimiter
>
Appends the specified characters to every <
str#
> string.
For example, if a protocol requires that all strings to and from a device have a
carriage return/linefeed, then <
delimiter
> can be
"\x0D\x0A".
The delimiter applies to incoming and outgoing strings.
Digital output
<
Carrier Detect
>
This line indicates an established a carrier with a remote device.
Digital output
<
Ring In
>
The ring indicator tells the software that a remote device is calling.
Slot 4: C2QENET-1: C2ZQ-Ethernet
The C2QENET-1 built-in network interface card provides one LAN port with an
RJ-45 connector for connecting the QM-RMCRX-BA to the Ethernet network.
NOTE:
C2N-NPA8 is not supported.
The card provides 252 IP IDs for Ethernet devices. No symbol is shown, as no
detail is required.
Slot 5: Cresnet: C2Net-Device
The C2Net-Device slot enables the QM-RMCRX-BA to control up to 252
Cresnet devices. Each Cresnet device is assigned a unique identifier called a Net
ID, which is a hexadecimal value ranging from 03 to FE.
To view the list of supported devices, expand the control system in the bottom
pane of
System Views
and double-click the C2Net-Device slot, the desired Net
ID, or right-click and select
Add Item
from the submenu. Then select the device
you want to add. Alternatively, you can drag the device from the Cresnet
Control Modules folder onto the Net ID. Supported devices include network
control modules, lighting modules and a variety of Crestron wired touchpanels.
In Program Manager, the C2Net-Device symbol contains no signals; to program
a controlled Cresnet device, expand C2Net-Device in
Program View
. Then drag
each device to
Detail View
.
Operations Guide – DOC. 6332
QuickMedia™ Receiver/Processor: QM-RMCRX-BA
•
45
Содержание QM-RMCRX-BA
Страница 1: ...Crestron QM RMCRX BA QuickMedia Receiver Processor Operations Guide...
Страница 4: ......