  Lutron® Keypad: CNWM-LU12

Operations & Installation Guide - DOC. 8150

Setup

Network Wiring

NOTE:

  If making category 5 wire connections, refer to the latest revision of the

Cresnet Mini Network Cat 5 Interconnect Drawing (Doc. 5819). The document can
be obtained from the Downloads page (CABLES and MANUALS Libraries) of
Crestron’s website (

www.crestron.com)

. Search for the CAT5.PDF file.

When calculating the wire gauge for a particular Cresnet run, the length of the run
and the load factor of each network unit to be connected must be taken into
consideration. If Cresnet units are to be daisy-chained on the run, the load factor of
each unit to be daisy-chained must be added together to determine the load factor of
the entire chain. If the unit is a home-run from a Crestron system power supply
network port, the load factor of that unit is the load factor of the entire run. The
length of the run in feet and the load factor of the run should be used in the following
resistance equation to calculate the value on the right side of the equation.

Resistance Equation

R     =     R e s istance (refer to next table).
L    =  Length of run (or chain) in feet.
LF =  Load factor of entire run (or chain).

R     <

L   x   L F

4 0 ,000

Where:

The required wire gauge should be chosen such that the resistance value is less than
the value calculated in the resistance equation. Refer to the table below:

Wire Gauge Values

R E S I S T A N C E   ( R )

W I R E   G A U G E

4

1 6

6

1 8

1 0

2 0

1 5

2 2

1 3

2 4   ( D o u b l e d - C A T   5 )

NOTE:

  All Cresnet wiring must consist of two twisted-pairs. One twisted pair is the

+24V conductor and the GND conductor and the other twisted pair is the Y
conductor and the Z conductor.

NOTE:  

When daisy-chaining Cresnet units, always twist the ends of the incoming

wire and outgoing wire which share a pin on the network connector. After twisting
the ends, tin the twisted connection with solder. Apply solder only to the ends of the
twisted wires. Avoid tinning too far up the wires or the end becomes brittle. After
tinning the twisted ends, insert the tinned connection into the Cresnet connector and
tighten the retaining screw. Repeat the procedure for the other three conductors.

Содержание Lutron CNWM-LU12

Страница 1: ......

Страница 2: ...on 1 Physical Description 1 Leading Specifications 3 Setup 4 Network Wiring 4 Keypad Installation 5 Identity Code 6 Programming with SIMPL Windows 6 CNWM LU12 Symbol 7 How the Example Program Works 7 Problem Solving 9 Troubleshooting 9 Further Inquiries 9 Return and Warranty Policies 10 Merchandise Returns Repair Service 10 CRESTRON Limited Warranty 10 ...

Страница 3: ......

Страница 4: ...structions The keypad has 12 functionally identical buttons and 10 of the buttons have associated light emitting diodes LEDs for user feedback indicators All buttons are momentary switches and provide digital inputs to the Cresnet system The illumination of the LEDs which are independently addressable is programmed by SIMPL Windows Physical Description The CNWM LU12 keypad is shown on the next pag...

Страница 5: ...LED LAYOUT VIEWED FROM FRONT BUTTON 1 LED 1 BUTTON 2 LED 2 BUTTON 3 LED 3 BUTTON 4 LED 4 BUTTON 5 LED 5 BUTTON 6 LED 6 BUTTON 7 LED 7 BUTTON 8 LED 8 BUTTON 9 LED 9 BUTTON 10 LED 10 BUTTON 11 WHITE NO LED BUTTON 12 GREY NO LED LEDs 1 10 BUTTONS 1 12 GROUND WIRE CNWM LU12 ZA11216 4 58 in 11 63 cm 2 73 in 6 93 cm DEPTH 1 20 in 3 05 cm C000000 SEE MANUAL FCC ID EROCN LUPAK NET 24 Y Z G LUTRON LUTRON F...

Страница 6: ...cm 3 Weight 6 10 oz 0 17 kg 1 The latest software versions can be obtained from the Downloads page SIMPLWIN and MACROS Libraries of Crestron s website www crestron com New users are required to register in order to obtain access to the FTP site 2 CNX upgrade files are required for either CNMSX AV Pro or CNRACKX DP Filenames for upgrade files have a UPZ extension and can be obtained from the Downlo...

Страница 7: ...e used in the following resistance equation to calculate the value on the right side of the equation Resistance Equation R Resistance refer to next table L Length of run or chain in feet LF Load factor of entire run or chain R L x LF 40 000 Where The required wire gauge should be chosen such that the resistance value is less than the value calculated in the resistance equation Refer to the table b...

Страница 8: ...xt step do not use excessive force when prying the faceplate away from the frame 2 Using a small flat tip screwdriver or your fingers pry the top or bottom of the faceplate away from the frame until the retaining tabs disengage Tilt the faceplate outward and the tabs on the opposite edge will release Separate the faceplate from the frame 3 At the electrical box connect the GREEN ground wire of the...

Страница 9: ... appears in the box below the list Use the scroll arrow to assign another NET ID 6 When the assigned NET ID appears select the Set ID button to initiate the change 7 The software responds with a successful message to confirm the changed NET ID 8 To verify this procedure select Diagnostics Report Network Devices Confirm that the keypad has a new NET ID code 9 Reconnect other Cresnet devices that we...

Страница 10: ...WM LU12 Symbol above for the correct location of the outputs NOTE There is no need to recreate the example SIMPL Windows program The program is available from the Software Downloads page EXAMPLES Library of Crestron s website www crestron com Search for CNWMLU12 SMW New users are required to register in order to obtain access to the FTP site The example SIMPL program for the CNWM LU12 is shown on ...

Страница 11: ...Lutron Keypad Crestron CNWM LU12 8 Lutron Keypad CNWM LU12 Operations Installation Guide DOC 8150 Example CNWM LU12 SIMPL Program ...

Страница 12: ...L W indows program Verify SIMPL Windows program for feedback signal names Keypad does not function when a button is depressed From the Viewport in SIMPL Windows or VT Pro poll the network F4 to verify the NET ID Further Inquiries If after reviewing this Operations Installation Guide for the CNWM LU12 you cannot locate specific information or have questions please take advantage of Crestron s award...

Страница 13: ...e date of shipment to purchaser Disk drives and any other moving or rotating mechanical parts are covered for a period of one 1 year CRESTRON warrants all its other products for a period of one year from the defects mentioned above excluding touchscreen display components which are covered for 90 days Incandescent lamps are completely excluded from Crestron s Limited Warranty CRESTRON shall at its...

Страница 14: ......

Отзывы: