infiNET™ SWITCHES
3. Push all power wires back into the wallbox and
fasten the device to the wallbox with the
provided screws.
Installation
4. Attach decorative faceplate.
WARNING:
Turn off power at the circuit breaker.
Installing with power on can result in serious personal
injury and damage to the device.
5. Restore power at the circuit breaker.
Wiring a -SWSXRF with One or More
-SLVS1RFs
NOTE:
The -SW1RF, -SW4RF, -SWS1RF, and
-SWS4RF require a neutral wire for operation. If no
neutral is present, the device will not work. If no neutral
is present, contact a licensed electrician for installation.
NOTE:
The -SWS1RF and -SWS4RF must be installed
in the same wallbox that contains the connections to the
load.
NOTE:
The -SWS1RF and -SWS4RF must be installed
in the same wallbox that contains the connections to the
load.
The following describes installation of a -SWSXRF
master with a -SLVS1RF slave.
NOTE:
New installations should be checked for short
circuits prior to installing the -SW1RF, -SW4RF,
-SWS1RF, -SWS4RF, or -SLVS1RF. With power off,
close the circuit and restore power. If the load does not
work or a breaker trips, check and correct the wiring or
fixture (if necessary). Install the -SW1RF, -SW4RF, -
SWS1RF, -SWS4RF, or -SLVS1RF only when the short
is no longer present.
The warranty is void if the
-SW1RF, -SW4RF, -SWS1RF, -SWS4RF, or
-SLVS1RF is installed and operated with a shorted
load
.
1. Turn power off at the circuit breaker.
2. Wire the switches as shown in Figure 3 on
page 8.
NOTE:
Do not connect the BLUE (Slave) wire
to the Black (Hot) or RED (Load) wires.
NOTE:
The RED (Load) and BLACK (Hot)
wires are #14 AWG. The BLUE (Slave) and
WHITE (Neutral) wires are #18 AWG. The
GREEN (Ground) wire is #16 AWG.
When installing a -SWXRF or a -SWSXRF without a
slave, follow the instructions in “Wiring a -SW(S)XRF
(No Slaves)” below. If wiring a -SWSXRF with a
-SLVS1RF, refer to “Wiring a -SWSXRF with One or
More -SLVS1RFs” in the next column.
NOTE:
If a -SWS1RF or -SWS4RF is installed
without a -SLVS1RF, the BLUE lead (Slave)
should be capped.
NOTE:
The WHITE (Neutral) connection on
the -SLVS1RF is optional and is only required
for operation of the LED. If the neutral is not
available, the white lead should be capped off.
Wiring a -SW(S)XRF (No Slaves)
The following describes the installation of a stand-alone
-SW1RF, -SW4RF, -SWS1RF or -SWS4RF.
3. Push all power wires back into the wallbox and
fasten the devices to their respective wallboxes
with the provided screws.
1. Turn power off at the circuit breaker.
2. Wire the switch as shown in Figure 1 on
page 8.
4. Attach
decorative faceplates.
5. Restore power at the circuit breaker.
NOTE:
The RED (Load) and BLACK (Hot)
wires are #14 AWG. The BLUE (Slave) and
WHITE (Neutral) wires are #18 AWG. The
GREEN (Ground) wire is #16 AWG.
NOTE
: Since the -SWS1RF or -SWS4RF is
installed without a -SLVS1RF, the BLUE lead
(Slave) should be capped.
Other Wiring
For another scenario that may be encountered
during installation, refer to Figure 2 on page 8.
Installation Guide - DOC. 6293A
infiNET™ Wall Box Switch: CLW-SW1/4RF, SWS1/4RF, & SLVS1RF
•
5