infiNET™ SWITCHES
•
Wallboxes: Devices mount in standard
wallboxes. For easy installation, Crestron
recommends using 3 ½” deep wallboxes. Several
devices can be installed in one wall box
(multigang). This requires the removal of side
sections (refer to diagram on page 4) and the
derating of the switching device. For a smooth
appearance, one-piece multigang faceplates (not
supplied) can be installed.
Derating Information for Incandescent, Tungsten Halogen,
and Electronic Low Voltage Applications
Part Number
No Side
Removed
One Side
Removed
Two
Sides
Removed
-SW1RF/
-SW4RF
1000W
700W
550W
-SWS1RF/
-SWS4RF
1000W
700W
550W
-SLVS1RF
No Derating Necessary
•
Other Switch Devices: Mechanical 3- or 4-way
switches will not work with the -SW1RF,
-SW4RF, -SWS1RF, -SWS4RF, and -SLVS1RF.
Derating Information for Magnetic Low Voltage and
Neon/Cold Cathode Applications
*
Part Number
No Side
Removed
One Side
Removed
Two Sides
Removed
-SW1RF/
-SW4RF
1000VA/
750W
700VA/
500W
550VA/
400W
-SWS1RF/
-SWS4RF
1000VA/
750W
700VA/
500W
550VA/
400W
-SLVS1RF
No Derating Necessary
•
Spacing: If mounting one device above another,
leave at least 4 ½” vertical space between them.
Multigang Installations
In multigang installations, several controls are grouped
horizontally in one wallbox. For a smooth appearance,
one-piece multigang faceplates (not supplied) can be
installed.
* VA ratings are for input power to the transformer. If you do not
know the input power requirement of the transformer, use the bulb’s
wattage rating to determine proper rating.
1. When combining controls in a wallbox, remove
inner side sections prior to wiring (refer to the
following figure).
Derating Information for Fluorescent/HID Applications
Part
Number
No Side
Removed
One Side
Removed
Two Sides
Removed
-SW1RF/
-SW4RF
8A 5.5A
4.5A
-SWS1RF/
-SWS4RF
8A
5.5A
4.5A
-SLVS1RF
No Derating Necessary
Inner Sections of Multiganged Switches
(CLW-SW4RF Shown)
REMOVE INNER SECTIONS
DO NOT REMOVE OUTER SECTIONS
RUN
SET
OFF
RUN
SET
OFF
Derating Information for Ceiling Fans
Part
Number
No Side
Removed
One Side
Removed
Two Sides
Removed
-SW1RF/
-SW4RF
3A 3A 3A
-SWS1RF/
-SWS4RF
3A
3A
3A
-SLVS1RF
No Derating Necessary
2. To remove a side section, bend the side section
back and forth with a pair of pliers until the
section breaks off from the mounting plate. Use a
file or sandpaper to remove any excess metal.
The load capacity must also be derated. The
following charts provide derating information for
various applications.
4
•
infiNET™ Wall Box Switch : CLW-SW1/4RF, SWS1/4RF, & SLVS1RF
Installation Guide - DOC. 6293A