13
Setup
Network Wiring
When wiring the DM network, consider the following:
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
CAUTION:
Failure to use Crestron power supplies could cause equipment
damage or void the Crestron warranty.
Provide sufficient power to the system.
For DM 8G+ wiring, use Crestron DM-CBL-8G DigitalMedia 8G cable,
Crestron DM-CBL DigitalMedia cable, Crestron DM-CBL-D DigitalMedia
D cable, or generic CAT5e (or better) UTP or STP. Maximum wire length
for DM 8G+ is 330 feet (100 meters) between devices. Shielded cable and
connectors are recommended to safeguard against unpredictable
environmental electrical noise which may impact performance at resolutions
above 1080p. Refer to the latest version of the Crestron DigitalMedia
Design Guide (Doc. 4546) for complete system design guidelines. DM 8G+
is also compatible with HDBaseT Alliance specifications for connecting to
HDBaseT compliant equipment.
The DM-RMC-100-C also uses high-speed Ethernet for communications between
the device and a control system, computer, media server, and other IP-based devices.
For general information on connecting Ethernet devices in a Crestron system, refer to
the latest version of the Crestron e-Control
Reference Guide (Doc. 6052), which is
available from the Crestron Web site (
www.crestron.com/manuals
). For information
specifically related to Ethernet connectivity using DigitalMedia devices, refer to the
latest version of the Crestron IP Considerations Guide for the IT Professional (Doc.
4579), which is also available from the Crestron Web site
(
www.crestron.com/dmresources
).
Identity Code
NOTE:
In the SIMPL Windows
program, the IP ID of the DM-RMC-100-C is
assigned automatically and does not require additional programming when the
DM-RMC-100-C is dropped onto an output card of a DM switcher. Use the
information below when the DM-RMC-100-C is dropped directly into an Ethernet
slot on the control system in SIMPL Windows without a DM switcher.
The IP ID is set within the DM-RMC-100-C IP table using Crestron Toolbox™.
For information on setting an IP table, refer to the Crestron Toolbox help file.
The IP IDs of multiple DM-RMC-100-C devices in the same system must be unique.
When setting the IP ID, consider the following:
The IP ID of each unit must match an IP ID specified in the SIMPL
Windows program.
Each device using IP to communicate with a control system must have a
unique IP ID.