Crestron Electronics, Inc.
Operations Guide – DOC. 5980
15 Volvo Drive Rockleigh, NJ 07647
02.02
Tel: 888.CRESTRON
Fax: 201.767.7576
Specifications subject to
www.crestron.com
change without notice.
Страница 1: ......
Страница 2: ...This document was prepared and written by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON ...
Страница 3: ...ary Symbols 13 Converting Programs and Modules Created for other Systems 18 Establishing Communication with the CP2 CP2E 20 Troubleshooting Communications 22 Compiling and Uploading a Program to the Control System 24 Uploading Web pages to the CP2E 25 Uploading Touchpanel Projects via the CP2 CP2E 26 Updating the Operating System 26 Advanced Console Commands 27 Troubleshooting 28 Passthrough Mode ...
Страница 4: ......
Страница 5: ...supports dynamic static IP addressing and full duplex TCP IP and UDP IP protocols With speed power and massive memory the 2 Series control systems are ideal for enhanced applications like media help desks videoconferencing distance learning and entertainment facilities Functional Summary Powered by 2 Series Control Engine 36 MB of Internal Memory 8 IR Serial Ports 8 Isolated Relay Ports 8 I O Vers...
Страница 6: ...ons HWR SWR 1 Cresnet 4 wire interface Expandable via Cresnet Poll Accelerator 1 DB9F PC interface 8 Simultaneous one way IR or serial output 8 Programmable digital analog inputs digital outputs 8 Normally open isolated relays MOV suppression 1 RJ45 10 100 BaseT Ethernet port 3 DB9 bidirectional serial ports RS 232 422 485 all Cresnet Poll Accelerator ready 1 Male receptacle for optional external ...
Страница 7: ...nt Panels The rear panels of the units are shown below Both units contain a single RS 232 computer port a network connector three COM ports eight one way IR serial ports eight I O ports eight relay ports and a 24VDC male receptacle for power supplied through an AC power pack purchased separately The CP2E also contains a single Ethernet port CP2 CP2E Rear Panels Rubber feet are supplied and can be ...
Страница 8: ...u Functions 2 Series errorlog LNK LAN CP2E only This LED illuminates when there is a connection to the rear panel LAN port ACT LAN CP2E only This LED illuminates when there is communication activity at the rear panel LAN port HWR Pressing this button initiates system hardware reset Same effect as disconnecting and reconnecting power SWR Pressing this button in combination with the HWR button perfo...
Страница 9: ...pin port is non standard refer to the table after these notes titled Non Standard COM Pinout it contains RS 422 pins in addition to RS 232 This may result in a conflict with some equipment and therefore all nine pins should not be used Only the required pins for each communication type should be connected For RS 232 and 422 pins 2 3 5 7 and 8 are wired straight through NOTE Data Set Ready DSR and ...
Страница 10: ...vides eight software programmable analog and digital inputs as well as digital outputs Digital outputs offer 250mA sync from maximum 24 VDC catch diodes for use with real world loads Digital inputs are rated 0 24 VDC 20K ohms input impedance logic threshold 1 25 VDC Analog inputs are rated 0 10 VDC protected to 24 VDC maximum 20K ohms input impedance pin programmable 2K ohms pullup resistor to 5V ...
Страница 11: ...it In those network configurations that require more power than can be supplied by Crestron s Power Control Unit alone disconnect the 24 VDC Cresnet wire from those devices that will be powered by an AC power pack LAN CP2E only LAN This built in 10 100 BaseT Ethernet RJ45 port CP2E only provides local area network or Web access Refer to the following table for the Ethernet connector signals and us...
Страница 12: ...is preserved to maintain file checksums Non volatile 1 SIMPL Modules 2 SIMPL Variables using nonvolatile qualifier or DEFAULT_NONVOLATILE 3 SIMPL Program 4 Operating System cuz file 5 Signals explicitly written to NVRAM by symbols such as Analog RAM Analog RAM from database Serial RAM Serial RAM from database Analog Non volatile Ramp Digital RAM etc NOTE If you extract NVRAM values to a file Viewp...
Страница 13: ...ng this unit in a rack take special precautions to ensure that the system remains stable The following guidelines are provided to ensure your safety When mounting this unit in a partially filled rack load the rack from the bottom to the top with the heaviest component at the bottom of the rack If the rack is provided with stabilizing devices install the stabilizers before mounting or servicing the...
Страница 14: ...s than four the strip can be trimmed to size with a pair of scissors or wire snips 2 Loosen the terminal block screws and insert the first leg of the bussing strip into the first common position on the terminal block The strip engages the other common positions automatically 3 Remove approximately 1 8 of the jacket from the common wire and insert the conductor into one of the terminal block common...
Страница 15: ...24V conductor and the GND conductor and the other twisted pair is the Y conductor and the Z conductor NOTE For larger networks i e greater than 28 network devices it may be necessary to add a Cresnet Hub Repeater CNXHUB to maintain signal quality throughout the network Also for networks with lengthy cable runs it may be desirable to add a hub repeater after only 20 network devices When calculating...
Страница 16: ...ns Consideration must be given if installed in a closed or multi unit rack assembly since the operating ambient temperature of the rack environment may be greater than the room ambient Contact with thermal insulating materials should be avoided on all sides of the unit NOTE The maximum continuous current from equipment under any external load conditions shall not exceed a current limit that is sui...
Страница 17: ...anager for designing the logic and functionality of the control system In addition you can use Crestron s powerful Viewport utility to accomplish multiple system tasks such as uploading the program to the control system and performing diagnostic functions Together with the Crestron Database these tools provide you with the essential components you need to program the CP2 CP2E Crestron software is ...
Страница 18: ...serial communication in a variety of formats including infrared and one way RS 232 Of course different devices may require additional receiving equipment cables adapters etc To add an IR device to the system drag the device driver from the Crestron or User IR Database to a C2I IR8 port To add an RS 232 device drag the C2IR one way serial driver from the Serial Drivers folder to a C2I IR8 port Alte...
Страница 19: ...value MinChange1 through MinChange8 All Versiport modes For each Versiport one corresponding pullup resistor pu disable1 through pu disable8 Defining a signal puts the signal into the corresponding mode For example defining the analog input i1 configures that Versiport as an analog input A Versiport can only operate in one mode That is if you define o1 you should not also define i1 Description Int...
Страница 20: ...ensor or a voltage source both can be represented by box A in the Versiport diagram When a resistive load is tied to a Versiport the corresponding pullup resistor must be enabled again this means that pu disable should be given the signal name 0 or left undefined This creates a voltage divider and provides a varying voltage level based on the current resistance of the sensor for the C2I IO8 to rea...
Страница 21: ...evice to the system expand the C2ENET 1 slot and double click the desired IP ID or right click and select Add Item from the submenu Then select the device you want to add In Program Manager the C2ENET 1 symbol contains no signals to program a controlled Ethernet device expand the C2ENET 1 symbol in Program View Then drag the symbol to Detail View Alternatively you can double click the symbol About...
Страница 22: ...port to open the Device Settings dialog box and then click the Serial Settings tab These settings define the protocol that a controlled serial device expects and include the baud rate parity and the number of data bits and stop bits In addition a device might require hardware or software handshaking which controls the flow of data between two devices The exact protocol will be described in the man...
Страница 23: ...s shown in the following illustration SIMPL Toolbar NOTE Note that you can select both X and 2 Series as the targets so that the module will work for both types of control systems However you will be limited to SIMPL keywords and functions that are supported on both systems If you do not choose a target then the module may or may not work depending on the constructs that are used 3 Save and compil...
Страница 24: ...t the COMPUTER port on the control system to one of the COM ports usually COM 1 on the PC Use a straight through RS 232 cable with a DB9 male connector on one end and a DB9 female connector on the other Most commercially available cables are acceptable they should have at least 5 pins for transmit receive ground and hardware handshaking Open the Crestron Viewport and click Setup Communication Sett...
Страница 25: ...CP IP settings 1 Open Viewport and click Functions Set Control System IP Information 2 Enter the IP address IP mask and default router in the text fields All of these terms are explained in detail in Crestron s e Control Reference Guide DOC 6052 available as a PDF on the Crestron website 3 Click OK to set the new IP information Once you have assigned the IP settings you can continue to communicate...
Страница 26: ...og box that gives the IP address and port number Troubleshooting Communications Use the following checklist if communication cannot be established with the CP2 CP2E 1 Verify that you are using the correct cables As described previously an RS 232 connection requires a straight through serial cable That is pin 1 on one end is connected to pin 1 on the other end Pin 2 connects to pin 2 etc With a TCP...
Страница 27: ... three to five seconds The Viewport console should display the following message Viewport Message Release the SWR button d If communication still cannot be established Remove power from the control system Press and hold the SWR button on the front panel of the CP2 CP2E Reapply power to the control system The Viewport console should display the message shown above Release the SWR button e Select Se...
Страница 28: ...trol system 2 Alternatively click the Transfer button on the SIMPL Windows toolbar or open Viewport and click File Transfer Send Program 3 Click Browse locate the SPZ file and click Open This will display the program s header information and enable one or both of the What to Send check boxes If the program does not contain any SIMPL modules only the SIMPL Program check box will be enabled If it do...
Страница 29: ...IMPL Windows program The PC Interface symbol is one of the Ethernet Modules that can be dropped into the C2ENET 1 card slot As with all Ethernet devices the PC Interface must receive an entry in the IP Table of the CP2E Here the IP ID must match the IP ID that was assigned in VT Pro e while the IP address must be set to localhost 127 0 0 1 Viewport To transfer the Web pages to the CP2E use the Fil...
Страница 30: ... are as follows All Files in Project sends the entire project Only Changed Files sends only the files that are different from those that are currently stored in the panel Note that if any pages in the panel are not present in the project those pages will be deleted from the panel Additional choices include Do not send graphic files and Do not send sound files These are often very large files that ...
Страница 31: ...ial connection RS 232 with a PC over Ethernet via the LAN port or through Telnet among many other methods It is also possible to issue console commands through logic by adding a Console symbol to the SIMPL Windows program The Console symbol is only visible in the Symbol Library when Special is selected as the Symbol Set Click Edit Preferences In the Symbol Set area of the General tab select Specia...
Страница 32: ...e network F4 from the Viewport check error log for SIMPL SIMPL program reload errors Compilation error RLCMCVT166 RLCMCVT177 Poor analog versus serial signal definition in the SIMPL Windows program Confirm properly defined signal definition in the program System locks up Various Press front panel SWR and HWR buttons at the same time to bypass program and communicate directly with processor refer t...
Страница 33: ... given port illuminate when in Passthrough mode Entering Passthrough mode for one of the internal COM ports reinitializes it which clears the data for that port To establish communication click Functions Enter Passthrough Mode Then select the connection type that exists between the CP2 CP2E and the device The choices are Slot for devices connected to the control system via one of the card slots on...
Страница 34: ... Mode Dialog Box The PC will now be communicating directly with the device To exit Passthrough mode simply click Functions Exit Passthrough Mode A system reboot will also exit Passthrough mode 30 2 Series Integrated Control Processor CP2 CP2E Operations Guide DOC 5980 ...
Страница 35: ...a at 852 2341 2016 In Latin America call Crestron Latin America at 5255 5093 2160 In Australia and New Zealand call Crestron Pacific at 613 9480 2999 Future Updates As Crestron improves functions adds new features and extends the capabilities of the CP2 CP2E additional information may be made available as manual updates These updates are solely electronic and serve as intermediary supplements prio...
Страница 36: ...mands data or instructions from or to another computer b for local campus or wide area network internet or web hosting services or c pursuant to any rental sharing or service bureau arrangement The Software is designed as a software development and customization tool As such Crestron cannot and does not guarantee any results of use of the Software or that the Software will operate error free and Y...
Страница 37: ...ninety 90 days from the date of receipt and b that any hardware accompanying the Software will be subject to its own limited warranty as stated in its accompanying written material Crestron shall at its option repair or replace or refund the license fee for any Software found defective by Crestron if notified by you within the warranty period The foregoing remedy shall be your exclusive remedy for...
Страница 38: ...vered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been used in any application other than that for which it was intended or if it has been subjected to misu...
Страница 39: ...Crestron CP2 CP2E 2 Series Integrated Control Processor This page intentionally left blank Operations Guide DOC 5980 2 Series Integrated Control Processor CP2 CP2E 35 ...
Страница 40: ...Crestron Electronics Inc Operations Guide DOC 5980 15 Volvo Drive Rockleigh NJ 07647 02 02 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...