Crestron CNX-BIPAD8 Скачать руководство пользователя страница 10

 Professional Audio Distribution Processor 

Crestron 

CNX-BIPAD8

 

 Professional Audio Distribution Processor:  CNX-BIPAD8 

 Operations Guide - DOC. 8160A 

ROOMS 

The eight, shielded RJ-45 connectors provide for balanced line audio to/from remote 
locations in the facility; one CAT5 stereo input and output per connector. Signal 
connections for the jacks are given in the following table. 

 

Pin # 

Signal 

Audio In L +  

Audio In L - 

Audio In R + 

Audio Out L - 

Audio Out L + 

Audio In R - 

Audio Out R + 

Audio Out R - 

NOTE:

  For additional information on audio/video connections over CAT5, refer to 

the latest version of the Crestron CAT5 Wiring Reference Guide (Doc. 6137) which 
is available from the Downloads | Product Manuals section of the Crestron website 
(www.crestron.com)

The eight pairs of RCA jacks output pre-amplified (line-level) and volume/tone 
processed audio to corresponding room power amplifiers. Each room output contains 
left and right audio channels. (These are the same signals as the unprocessed outputs 
from the CAT5 connectors.) 

1 – 16 (Source Connectors) 

The sixteen sets of four RCA jacks connect independent audio sources to the CNX-
BIPAD8. Of each set, two of the connectors are used for left and right audio 
channels; the other two are parallel stereo loop-throughs. 

 (Chassis Ground) 

Use this chassis screw to connect the audio source(s) common ground(s) to the 
CNX-BIPAD8. 

Indicators 

Ten LED indicators on the front panel indicate the unit’s current status. 

CNX-BIPAD8 Indicators 

ROOMS

4

2

5

3

8

7

6

1

NET

P WR

P  R  O  F  E  S  S  I  O  N  A  L    A  U  D  I  O    D  I  S  T  R  I  B  U  T  I  O  N    P  R  O  C  E  S   S  O  R

CRESTRON

CNX-BIPAD8

 

PWR (Power) 

This LED illuminates when 24 volts DC is supplied to the CNX-PAD8. 

JACK, REAR VIEW

(TAB POSITION DOWN)

Pin 1

Содержание CNX-BIPAD8

Страница 1: ...Crestron CNX BIPAD8 Professional Audio Distribution Processor Operations Guide ...

Страница 2: ...n by the Technical Documentation department at Crestron Electronics Inc 15 Volvo Drive Rockleigh NJ 07647 1 888 CRESTRON All brand names product names and trademarks are the property of their respective owners 2003 Crestron Electronics Inc ...

Страница 3: ...dware Hookup 10 Typical Room Configurations 11 Signal Distribution to More than Eight Rooms 12 Expanded Distribution of Local Audio Sources 13 Programming Software 15 Earliest Version Software Requirements for the PC 15 Programming with SIMPL Windows 15 Uploading and Upgrading 19 Communication Settings 19 Uploading a SIMPL Windows Program 21 Firmware Upgrade 23 Problem Solving 24 Troubleshooting 2...

Страница 4: ......

Страница 5: ...n distributes the audio to up to eight room amplifiers or Crestron room control boxes The unit s sixteen stereo head end audio inputs are RCA type connectors with loop through These inputs plus the eight additional CAT5 stereo inputs pass through a stereo 24x8 cross point switch Each output of the cross point switch goes to a differential driver to the CAT5 connectors The same cross point outputs ...

Страница 6: ...vels and controls the relative audio level within that range Balance Bass and Treble Specifies levels for these settings relative to a 50 neutral or balanced signal Mono Changes the audio setting from stereo to mono monaural mode Compensation Source gain compensation that normalizes input levels from different sources for example setting the volume range of a VCR equal to that of a CD player Mute ...

Страница 7: ...put and output per connector Tone specifications per channel Flatness 8 to 60 KHz flat mode 0 2 dB Bass gain range 100 Hz 12 dB Bass step size 100 Hz 2 dB Treble gain range 10 KHz 12 dB Treble step size 10 KHz 2 dB Preamp specifications per channel Input impedance 47K Ohms Total harmonic distortion THD 0 02 S N ratio 100 dB Maximum input level flat mode 3 2 Vrms Maximum output level 2 5 Vrms Chann...

Страница 8: ...ependent Programmers CAIP only New users may be required to register to obtain access to certain areas of the site including the FTP site Physical Description The CNX BIPAD8 is housed in a black enclosure with labeling on the front and rear panels Ten LEDs on the front panel indicate the unit s current status All connections are made to the back of the unit Refer to the following illustrations of ...

Страница 9: ...D I S T R I B U T I O N P R O C E S S O R CRESTRON CNX BIPAD8 8 250 in 20 955 cm RIGHT LEFT 1 2 3 4 5 6 7 RIGHT LEFT 9 10 13 11 12 14 15 5 8 RIGHT LEFT 1 2 3 4 6 7 8 ROOMS 16 SETUP 24 Y Z G NET CRESTRON ELECTRONICS INC ROCKLEIGH N J 07674 USA CNX BIPAD8 Ports All connections to the CNX BIPAD8 are made through the ports on the rear panel Refer to the illustrations and descriptions which follow NET ...

Страница 10: ...e eight pairs of RCA jacks output pre amplified line level and volume tone processed audio to corresponding room power amplifiers Each room output contains left and right audio channels These are the same signals as the unprocessed outputs from the CAT5 connectors 1 16 Source Connectors The sixteen sets of four RCA jacks connect independent audio sources to the CNX BIPAD8 Of each set two of the co...

Страница 11: ... been tested and found to comply with specifications for CE marking and standards per EMC and Radiocommunications Compliance Labelling N11785 NOTE This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 these devices may not cause harmful interference and 2 these devices must accept any interference received including interference that may cause un...

Страница 12: ...h solder Apply solder only to the ends of the twisted wires Avoid tinning too far up or the tinned end becomes brittle and breaks After tinning the twisted ends insert the tinned connection into the network connector and tighten the retaining screw Repeat the procedure for the other three network conductors Identity Code Every equipment and user interface within the Cresnet system requires a uniqu...

Страница 13: ...erify the new NET ID code 10 In the Set Network ID window click Close NOTE The new NET ID code may also be verified by selecting Diagnostic Report Network Devices in the Viewport 11 Repeat this procedure for each CNX BIPAD8 to be added to the network Rack Mounting WARNING To prevent bodily injury when mounting or servicing this unit in a rack take special precautions to ensure that the system rema...

Страница 14: ...hillips screwdriver tighten an additional 1 8 turn 5 Repeat procedure steps 1 and 2 to attach ear to the other side 6 If the rear panel of the CNX BIPAD8 is accessible when mounted in the rack install the CNX BIPAD8 If the rear panel is NOT accessible perform the hookup procedure before rack installation Stacking Four feet are provided with the CNX BIPAD8 so that if the unit is not rack mounted th...

Страница 15: ...C ROCKLEIGH N J 07674 USA FROM AUDIO SOURCE AUDIO SOURCE LOOP THROUGH DAISY CHAIN TO ADDITIONAL BIPAD8 UNITS TO AUDIO SOURCE S GND S CONTROL SYSTEM AUDIO TO ROOM ZONE AMPLIFIER CAT5 REMOTE INPUTS OUTPUTS Typical Room Configurations The following figures show typical room head end audio configurations using the CNX BIPAD8 Head End Amplification with Speaker Level Distribution Head End Amplification...

Страница 16: ...bution to More than Eight Rooms Each CNX BIPAD8 is capable of distributing audio to eight rooms maximum It is possible to expand distribution to more rooms if additional CNX BIPAD8s are introduced to the system Crestron recommends a maximum of four CNX BIPAD8s per system Therefore audio can be distributed to a maximum of 32 rooms NOTE Connecting more than four CNX BIPAD8s via loop through may resu...

Страница 17: ...ooms connected to the balanced audio CAT5 I Os on other CNX BIPAD8s However if you wish to distribute local room source audio from rooms connected to the first CNX BIPAD8 to rooms connected to a second CNX BIPAD8 you need to use the CNX PBAR4 as shown in the diagram on the next page The CNX PBAR4 allows you to maintain the balanced CAT5 I O connection to from rooms 1 4 on the first CNX BIPAD8 then...

Страница 18: ...m 12 Room 8 x8 8 Total 16 Stereo Audio Inputs Total Local Sound System Unbalanced Audio CNXRMCLV Unbalanced Audio Local Video Source I O In Local Sound System Unbalanced Audio CNXRMCLV Unbalanced Audio Local Video Source I O In Local Sound System Unbalanced Audio CNXRMCLV Unbalanced Audio Local Video Source I O In Local Sound System Unbalanced Audio CNXRMCLV Unbalanced Audio Local Video Source I O...

Страница 19: ...de a CNX BIPAD8 developed for specific control system types smw projectname smw source file spz projectname spz compiled file for 2 series bin projectname bin compiled file for CNX generation csz projectname csz compiled file for CNX generation with SIMPL ush projectname ush compiled file for CNX generation with SIMPL header file usp projectname usp source code module for SIMPL NOTE In the followi...

Страница 20: ...2 system tree displays the CNX BIPAD8 in Slot 9 with a default NET ID of 44 as shown in the following illustration NOTE The first CNX BIPAD8 in a system is preset with a NET ID of 44 when its symbol is dragged into the upper pane of System Views Additional units are assigned different NET ID numbers as they are added C2Net Device Slot 9 Setting the Net ID in Device Settings Double click the CNX BI...

Страница 21: ...r NET ID hardware setting details refer to Identity Code on page 8 CNX BIPAD8 Symbol in Programming Manager Programming Manager is where programmers program a Creston control system by assigning signals to symbols The following graphic shows the CNX BIPAD8 symbol in the SIMPL Windows Programming Manager Detail View of the CNX BIPAD8 in SIMPL Windows Programming Manager The CNX BIPAD8 symbol is def...

Страница 22: ...a scaling factor 3 min vol1 to min vol8 A This input represents a scaling factor 3 comp src1 to comp src24 A This input represents a source gain compensation 4 Analog or Digital 1 The src for rm analogs select the audio source for the specified room For example to distribute audio from input 3 to room 2 src for rm2 must be set to 3 typically via an Analog Initialize symbol If src for rm equals 0 t...

Страница 23: ...er tasks Viewport can also function as a terminal emulator for generic file transfer All of these functions are accessed through the commands and options in the Viewport menus Therefore for its effectiveness as a support and diagnostic tool the Crestron Viewport may be preferred over development tools when uploading programs and projects The following sections define how one would upload a SIMPL W...

Страница 24: ...o the figure after this step From the Viewport menu select Setup Communications settings alternatively press Alt D to open the Port Settings window Setup Communications Settings Command 4 Select RS 232 as the connection type Verify that an available COM port COM 1 is shown after this step is selected and that all communication parameters and necessary options from the Port Settings window are sele...

Страница 25: ...the respective Operations Guide for the control system Uploading a SIMPL Windows Program A control system source file has the extension smw A compiled SIMPL Windows file has the extension spz for a 2 Series control system bin for CNX generation and csz for CNX generation with SIMPL The SIMPL Windows file can be uploaded to the control system using SIMPL Windows or via the Crestron Viewport Upload ...

Страница 26: ...does not contain any SIMPL modules only the SIMPL Program check box will be enabled If it does contain SIMPL modules then the SIMPL Program s check box will also be enabled Select one or both check boxes and then click Send Program to begin the transfer NOTE Refer to the respective Operations Guide for the control system for details about the other fields shown on the Send Program window Send Prog...

Страница 27: ...de but as Crestron improves functions adds new features and extends the capabilities of its products firmware upgrades are posted To upgrade the firmware complete the following steps 1 Make sure that Communication Settings that begins on page 19 has been performed 2 As shown after this step select File Transfer Load Network Device from the Viewport menu File Transfer Load Network Device Command 3 ...

Страница 28: ...r supply Power LED does not Illuminate CNX BIPAD8 is not receiving power Verify that cable plugged into NET port is secure Ensure sufficient NET power to support all NET devices NET LED does not illuminate Loose network connection Verify that cable plugged into NET port is secure Improper NET ID Verify that CNX BIPAD8 NET ID matches NET ID software program Refer to Identity Code on page 9 of this ...

Страница 29: ... Asia call Crestron Asia at 852 2341 2016 In Latin America call Crestron Latin America at 5255 5093 2160 In Australia and New Zealand call Crestron Control Solutions at 61 2 9737 8203 Future Updates As Crestron improves functions adds new features and extends the capabilities of the CNX BIPAD8 additional information and programming examples may be made available as manual updates These updates are...

Страница 30: ...een display and overlay components are covered for 90 days batteries and incandescent lamps are not covered This warranty extends to products purchased directly from CRESTRON or an authorized CRESTRON dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any CRESTRON shall not be liable to honor the terms of this warranty if the product has been...

Страница 31: ...Crestron CNX BIPAD8 Professional Audio Distribution Processor Operations Guide DOC 8160A Professional Audio Distribution Processor CNX BIPAD8 27 This page intentionally left blank ...

Страница 32: ...Crestron Electronics Inc Operations Guide DOC 8160A 15 Volvo Drive Rockleigh NJ 07647 2 03 Tel 888 CRESTRON Fax 201 767 7576 Specifications subject to www crestron com change without notice ...

Отзывы: