Master and Slave Operation
The CLW-DIMUEX-P supports multipoint dimming when used in
conjunction with a CLW-SLVU-P slave dimmer. Multipoint dimming is
similar to conventional 3- or 4-way switching, allowing dimming control of
a single load from multiple locations in the room.
For more information on master and slave operation, refer to the
(Doc. 7364).
Changing the Dim Mode
By default, the device is set to Auto Phase Dimming mode, which allows
the device to automatically toggle between forward and reverse phase
dimming based on the connected load. The device can be set to Auto
Phase Dimming mode or Forward Phase Dimming mode manually.
To set the dimming mode:
1. Open the air-gap switch as described in
.
2. While power is off, set the dimming mode:
l
Auto Phase Dimming Mode: Press and hold the top button cap.
l
Forward Phase Dimming Mode: Press and hold the bottom button
cap.
3. While holding the appropriate button, close the air-gap to restore
power to the connected load, the device buttons, and the LEDs.
4. After all LEDs have flashed once, release the button cap.
NOTE:
If the dimming mode is set in the control system program, the
LEDs will flash five times and the new mode will not be set. To modify
the parameter, change the setting in the control system program to
"Local Settings" and retry the operation.
5. After the released button's LED flashes once, the device will boot-up in
the selected dimming mode.
Wireless Communications
The device connects to the Crestron network via the infiNET EX
communications protocol. Use the procedures outlined below to join or
leave an infiNET EX network and to verify communications between the
device and the control system.
Joining an infiNET EX Network
Before a device can be used in a lighting system, it must first join an
infiNET EX network by being acquired by an infiNET EX gateway. The
CLW-DIMUEX-P is compatible with the CEN-GWEXER wireless gateway
and the MC4-R media room controller.
NOTE:
A device can be acquired by only one gateway.
1. Put the infiNET EX gateway into Acquire mode from the unit itself or
from Crestron Toolbox™ software, as described in either the
GWEXER and CEN-GWEXER-PWE Quick Start
(Doc. 7723) or the
(Doc. 8545).
NOTE:
In an environment where multiple gateways are installed, only
one gateway should be in Acquire mode at any time.
9
CLW-DIMUEX-P
Quick Start
Cameo® In-Wall Universal Phase Dimmer, 120 VAC