Regulators repair and maintenance
56
MC9 1
st
stage setting
• Check the pressure on the gauge. MC9 first stage is correctly set at
an intermediate pressure of 10 bars. If it is different, close the air
valve and discharge the regulator. Use a 6 mm. Allen wrench to
turn
clockwise
(+) the setting screw, in order to increase the first
stage intermediate pressure. Turning it
anticlockwise
(-), the
pressure will on the contrary decrease.
• Note: make sure to discharge the regulator before setting the
intermediate pressure, in order to avoid incorrect reading on the
gauge.
• Make sure the intermediate pressure is reached swiftly and stays so,
and does not increase after pressing the second stage discharge
button for more times.
• After the setting, when pressing the second stage discharge button,
the first stage pressure must decrease less than 1 bar.
January 2009
Rev. MC9/B Ed.C/13