background image

5925 Heisley Road • Mentor, OH 44060-1833

Series R-171-E

Refrigerated Cabinets

FL-2400

Rev. 2 (5/19)

Page 4 of 9

Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com

HOW TO OPERATE (CONT.):

b . To change the setpoint:

1 . Push the SET button for more than 2 seconds .  
2 . °F will begin blinking .  
3 . 

Use the ↑ or ↓ buttons to adjust the value.  

4 . Press the SET button or wait 10 seconds and 

the new value will be stored .

4.  The control stores the minimum and maximum 

temp values seen .

a . To view the MIN temperature: 

1 . 

Press the ↓ button.

2 . “Lo” will be displayed, followed by the 

minimum recorded temperature .

3 . 

Press the ↓ button again or wait 5 seconds to 

get back to the normal display .

b . To view the MAX temperature:

1 . 

Press the ↑ button.

2 . “Hi” will be displayed, followed by the 

maximum recorded temperature.

3 . 

Press the ↑ button again or wait 5 seconds to 

return to the normal display . 

c . To reset the MIN and MAX recorded 

temperatures:

1 . Go through one of the above procedures to 

display the MIN or MAX temperature .

2 . While the MIN or MAX temp is displayed, 

press and hold the SET button for more than 3 

seconds

3 . “rSt” will be blinking
4 . The control will go back to the normal display

5 . Under normal conditions, the controller is 

programmed to run a defrost cycle at optimal time 

intervals .

6 . If an additional defrost cycle is required, one can be 

forced .

a . Press the DEF key for more than 2 seconds .  

(This key looks like a melting snowflake.)

7. This unit is equipped with 2 different light fixtures 

for convenience and health . They are both 

triggered by a door opening event .

a . The LED light is set to illuminate the interior 

of the cabinet while the door is in the open 

position .

b . The UV light is set to sanitize the air at certain 

intervals while the door is closed .

c . Ensure the door gasket is aligned properly so 

that the door switch operates correctly .

d. If the door is open for an extended period of 

time, display will show door alarm “dA”

CAUTION: Ensure the door switch is operating 

properly. The sanitizing bulb is designed to work 

ONLY at certain times when door is CLOSED - if 

the door switch has failed, it may be on when the 

door is open.

WARNING Although the system is completely 

enclosed within the shroud in the evaporator 

assembly, it DOES still emit low energy ultraviolet 

waves. If the evaporator has been disassembled, 

take care NOT to look directly at the bulb or have 

your skin exposed for an extended period of time.

For greatest germicidal effect, it is recommended to 

change the UV bulb every 6 months. Only replace 

with genuine Cres Cor part.

8 . Locking out the control panel – to have the control 

locked out so that only the setpoint/min/max be 

viewable:

a. Press and hold the ↑ and ↓ buttons together for 

more than 3 seconds

b .“POF” will be displayed .

OPERATING INSTRUCTIONS

Содержание R-171-E Series

Страница 1: ...Call Toll free 877 CRES COR 273 7267 Fax 800 822 0393 www crescor com Cabinet model number Cabinet serial number Authorized Service Agency Ph Fax Keep this manual for future reference R 171 SUA 10E R...

Страница 2: ...POLICY and AGENCY LIST FL 1400 WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REPAIR SHOULD BE DONE BY AUTHORIZED SERVICE PERSONNEL...

Страница 3: ...ature control will turn on 3 Control will display internal cabinet temperature 4 Pre chill the cabinet for at least 1 hour before loading food NOTE DO NOT PUT HOT FOOD INTO COLD CABINET HOW TO OPERATE...

Страница 4: ...ditional defrost cycle is required one can be forced a Press the DEF key for more than 2 seconds This key looks like a melting snowflake 7 This unit is equipped with 2 different light fixtures for con...

Страница 5: ...door and lift up to remove door from cabinet 3 Unscrew and re mount the hinges and latch strike to the opposite sides of the cabinet 4 Remove the door hinges and the door latch Turn hinges and handle...

Страница 6: ...eaner manufacturer s directions HARD WATER SPOTS SCALE Vinegar 1 Swab or wipe with cloth 2 Rinse and dry Mild detergents include soaps and non abrasive cleaners MAINTENANCE HOW TO CHARGE AND SERVICE T...

Страница 7: ...Low charge 4b Frost buildup in evap coil activate manual defrost 4c Condenser fan 4d Compressor 5 Noisy compressor 5a High or low charge 5b Refrigerant contaminated 5c Defective compressor TROUBLE SHO...

Страница 8: ...0810 039 07 Door assembly 1221 672 1221 672 1221 672 1221 672 Evaporator Assembly 1416 072 1416 073 1416 072 240 1416 073 240 Evaporator Fan Assy 1416 072 01 1416 072 01 1416 072 240 01 1416 072 240 0...

Страница 9: ...escor com TEMPERATURE CONTROL CHASSIS GROUND DOOR SWITCH WAGO WAGO WAGO 7 8 6 5 10 11 9 13 9 1 2 3 4 11 12 WAGO 16 EVAPORATOR FAN EVAPORATOR WAGO WAGO WAGO WAGO 0812 906 CORD 14 3 SJO CABLE FROM CONTR...