Trendsetter 400/800
6
Trendsetter 400/800
Cleaning Inside the Output Device
Cleaning the Plate Roller
Cleaning the Edge Detection Strip
To open the front panel:
a. Rotate the two latches on the
front panel to the vertical position
(90° counterclockwise).
1
b. Lift the front panel.
Rotate the drum to expose
the edge detection strip.
2
Locate the blue plate roller:
2
Dampen a lint-free cloth with water, and
slide the cloth over the plate roller.
3
Dampen a cloth with isopropanol and swipe it
along the strip once, in one direction only.
3
To close the panels:
a. Pull down the front panel and
turn the locking latches.
4
The top access panel opens by itself.
b. Pull down the top panel and
then push on the two corners
to lock the internal latches.
* Refer to the
Operator Manual
for full details.
WARNING:
Risk of electrical shock if liquids are
alowed to run freely into the output device.*
CAUTION:
Be careful not to bump your head on
the raised panel.*
!