5
Trendsetter 400/800
Replacing the Air Supply Filters
Remove the old
fi lter and Install the
new one.
3
Replacing the 0.01 Micron Filter
Replacing the 5 Micron Filter
Tab
Bowl
Disconnect the compressed air.
1
5 micron fi lter
part number
55-0760
0.01 micron fi lter
part number
55-0759
Air pressure
drops to 0 psi.
Pull the fi lter tab down, rotate
the bowl a quarter turn (either
direction), and pull down.
2
5 micron fi lter
Reattach the bowl.
6
Replace the O-ring,
if necessary.
5
Clean inside the bowl.
4
Turn on the compressed air.
7
Air pressure rises to 80 psi.
Tab
Bowl
Pull the fi lter tab down, rotate
the bowl a quarter turn (either
direction), and pull down.
2
0.01 micron fi lter
Remove the old
fi lter and Install the
new one.
3
Reattach the bowl.
6
Replace the O-ring,
if necessary.
5
Clean inside the bowl.
4
* Refer to the
Operator Manual
for full details.
WARNING:
Remove air pressure from the
device before replacing an air fi lter.*
!