oscilloscopes with the probe attenuation set to x100. If the user selects a different resistor, the user
should ensure that the resistor has minimal insertion inductance.
Figure 12. SDN-414-01 (sold separately)
Due to the fast switching speeds associated with Cree SiC MOSFETs, the following steps must be
followed closely to yield the most accurate results possible:
Scope probes measuring V
DS
and V
GS
must have minimal loop area between the signal and
ground.
The oscilloscope probes measuring V
DS
and I
DS
must be properly deskewed.
Bulk capacitance may need to be added to the board to minimize DC link voltage sag during
two-pulse measurements. The amount will vary based on desired current level and pulse
width.
Figure 14 shows a two-pulse setup. Figure 15 shows the waveforms measured with this two-
pulse setup.