Creda Spa300c Скачать руководство пользователя страница 2

 

INTRODUCTION 

If you experience any difficulty with the installation or operation of your new 

shower, then please refer to the “What to do if things go wrong” section in this 

manual before contacting us. 

                                                                                                                                                                       

 

 

 

Section                                                    

 

Introduction  . . . . . . . . . . . . . . . . . . . . . .   

 

Important Safety Information  . . . . . . . . . .   

 

How to install your 

SPA300C  

Shower . . . . . 

 

 
 

Cold Water Inlet Pipe Configuration. . . . . . .   

 

Assembly of Accessories . . . . . . . . . . . . . . 

 

How to maintain your 

SPA300C Shower

. . . .    

 

Additional Accessories and Common Parts . .  

 

How to use your 

SPA300C Shower 

(Detailed) 

 

 

 

 

 

Page 

  

 

 

 

 

 

 

 

 

 

Section  

  

                                                

What to do if things go wrong (1) 

Self Help . . . . . . . . . . . . . . . . . . . . . . . . .  

 

What to do if things go wrong (2) 

Professional Service . . . . . . . . . . . . . . . . .  

 

How your 

SPA300C Shower

 Works . . . . . . .   

 

Creda After Sales Service  . . . . . . . . . . . . .  

 

Guarantee and Contact Details . . . . . . . . . . 

 

How to use your 

SPA300C Shower

 

(Summary)          

 

Page 

  

 

 

 

 

10 

 

11 

 

11 

 

12 

 

Thank you for purchasing a quality 

Creda SPA300C Shower

 manufactured in England. 

To enjoy your new shower at its best, please take time to read this manual thoroughly to 
familiarise yourself with all instructions, BEFORE beginning installation. 

Having done so, keep this manual handy for future reference. 

 

Your shower is designed to stabilise temperature changes caused by water pressure fluctuations.                                          

These can result from toilets being flushed or taps being turned on and off.  
When this happens your showering temperature will be held within a controlled band, provided that 
the minimum pressure required by the shower is maintained (see “Effect of Other Water Devices”). 

 

 

 
 

 

 

1.

 

Your shower has been designed for convenience, economy and safety of use, provided that it is 
installed, used and maintained in good working order and in accordance with our instructions and 

recommendations. 

 

2.

 

All wiring and installation must be supervised by a suitably qualified person. 

 

3.

 

THIS APPLIANCE MUST BE EARTHED. 

 

4.

 

The installation must be in accordance with the current edition of BS.7671 (

the “IEE Wiring

 

Regulations”)

 and “Part P” of the 

“Building Regulations”

 in force at the time of installation. 

Installations outside of England and Wales must also conform to any local regulations in effect. 

This appliance is intended to be permanently connected to the fixed electrical wiring of the mains 
supply with its own dedicated supply. 

 

5.

 

This appliance must 

NOT

 be fitted where it may be subjected to freezing conditions. 

 

6.

 

DO NOT

 switch the appliance on if you suspect it of being frozen.                                                             

Wait until you are sure it has thawed out. 

 

7.

 

DO NOT

 fit any sort of tap or control on the appliance outlet. The appliance is designed to have 

an open outlet and should only be used with “Creda” recommended fittings.  

 

   

        

8.

 

Take care to avoid restricting the outlet of the pressure relief device. If water is discharged from 
the pressure relief device, maintenance will be required before the appliance can be safely used. 

 

9. 

Isolate the mains electrical and water supply before removing the front cover of the appliance.

 

 

 

CONTENTS 

IMPORTANT SAFETY INFORMATION 

Содержание Spa300c

Страница 1: ...IMPORTANT This booklet should be left with the user after installation and demonstration CREDA SPA300C ELECTRIC SHOWER Installation and User Guide...

Страница 2: ...um pressure required by the shower is maintained see Effect of Other Water Devices 1 Your shower has been designed for convenience economy and safety of use provided that it is installed used and main...

Страница 3: ...g holes at the base of the brackets will be disclosed by removing the plastic fronts See Diagram 4 and instructions supplied with accessories for further details 5 If you have not yet done so remove t...

Страница 4: ...p valve 3 The heater can be fed from a header tank provided this has a minimum head of 7 metres 23ft 4 The cold water inlet connection supplied is a plain 15mm straight shank shaft This connector will...

Страница 5: ...on of the two are also suitable To aid installation you may find it convenient to move the flexible pressure relief valve outlet assembly by removing the two securing screws If you do please ensure th...

Страница 6: ...disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules We recommend a ceiling switch mounted in a convenient position 3 If you have decided to connect...

Страница 7: ...the shower as on page 8 or 12 and check Water gets to a satisfactory temperature and water flow can be adjusted by control knob E Knob E has been correctly engaged by ensuring that the knob turns app...

Страница 8: ...water to stabilise It is recommended that you do not wholly enter the water spray during this period even if the shower has just been used 5 Once a temperature setting to your liking has been achieve...

Страница 9: ...0 9000 420 UK only Water continues to flow when button D pressed to stop This is normal The shower includes a shutdown feature that means the water will continue to flow for up to 7 seconds after stop...

Страница 10: ...he shower Effect of Seasonal Incoming Water Temperature Changes The required water temperature is achieved by adjusting the rate of water flow Diagram 7 shows the principle involved in relating temper...

Страница 11: ...and on is leaflet The model and serial number are located on the bottom face of the shower Make a note of those numbers here and be sure to quote them if you call for advice Model Number 53 67_ _ _ _...

Страница 12: ...showering temperature turn knob E a small amount until you reach the desired showering temperature Turn clockwise for cooler or Turn anti clockwise for warmer 4 When you have finished showering press...