Creda AquaNoir Скачать руководство пользователя страница 4

 

 

 
 
 
 

WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY 

QUALIFIED PERSON. 

 

WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE 

SUBJECTED TO FREEZING CONDITIONS 

 

We recommend that the installation is done in the following sequence. 

 

a. Fixing the shower to the wall    b. Plumbing   c. Electrical connections 

 

a.

 

FIXING THE SHOWER TO THE WALL 

 

1.

 

Position the riser rail at a convenient height for majority of users as 
detailed in Diagram 1 and mark its position. 

 

2.

 

Position the heater so that the top of the unit is horizontal and level 

with, 

or a maximum of 0.6 metres (2ft) below the top of the 

riser rail

.                                                                                                

Choose a flat piece of wall to avoid the possibility of distorting the 
backplate, as this may make the front cover a poor fit. 

 

3.

 

Adjust the position to get the most convenient arrangement taking the following into account. 

 

 

The heater must not be mounted in the direct spray from the handset. 

 

 

The handset must not be able to come into contact with used water in the cubicle, bath or 

basin.  If it can, then a vacuum breaker must be fitted. 

 

4.

 

Fix the riser rail with screws provided.                                                                                                   
The fixing holes at the base of the brackets will be disclosed by removing the plastic fronts.      
See Diagram 6 and instructions supplied with accessories for further details.  

 

5.

 

If you have not yet done so, remove the front cover assembly by undoing the retaining screws at 

the top and bottom of the unit and lifting the cover off.                             

 

6.

 

Your shower unit not only accepts services from the top, bottom or rear.                                                                                                                   

It also accepts services from the left or right hand side of the unit.                                                                                                                                                      
Decide the position of the electrical cable into the unit.                                                                                                                            
If top entry is chosen, cut away the walls in the backplate as shown in Diagram 2a.  

 

If bottom entry is chosen, cut away                                                                                                     

the walls in the detachable bottom                                                                                                                                         
section as shown in Diagram 2b.                                                                                                                
The detachable bottom section is                                                                                                         

secured to the backplate by 2 screws. 

 

7.

 

Decide the position of entry of the                                                                                                            

cold water pipe into the unit.                                                                                                               
If top entry is chosen,                                                                                                                                
cut away the backplate as shown in                                                                                                     

Diagram 2a.                                                                                                                            

 

If bottom entry is chosen, cut away the                                                                                               
walls in the detachable bottom section                                                                                                                  
as shown in Diagram 2b.                                  

 

If rear, please read the section on plumbing.                                                                                                     

To aid installation, you may find it convenient to move the flexible pressure relief valve outlet 
assembly by removing the two securing screws. 
If you do, please ensure that they are fully tightened on re-assembly (see Diagram 2b).                                                                                          

HOW TO INSTALL YOUR 

AquaNoir  

SHOWER 

 

13 

WHAT TO DO IF THINGS GO WRONG (2) 

 

PROFESSIONAL SERVICE 

 

If the previous “Self Help” checks fail to restore the performance, you should seek professional help. 

 

The person who installed the shower is probably the best one to investigate and correct it and is 
certainly the person to contact if you have had a problem in the guarantee period. 

 

The following additional checklist is provided for the benefit of the qualified service person. 

 

WARNING:   SWITCH OFF THE ELECTRICITY AT THE LOCAL ISOLATOR                                           

BEFORE REMOVING THE COVER TO MAKE CHECKS 

 

Water too HOT 

Water flow restricted by blockage in filter of solenoid valve. 
Replace the solenoid valve. 

Water too COLD 

Check circuit through thermal cut-out. 

Check circuit through microswitches on the pressure switch & power selector. 
Check each element circuit. 
Check tightness of electrical connections. 

No control over  

water flow 

Check control knob is correctly engaged onto the stabiliser valve drive gear. 

Undo headworks of stabiliser valve. 

Check stabiliser is in place and remove any debris in valve then re-assemble. 

Water discharges  
from pressure     

relief valve 

Check for cause of high pressure and remove it. 
Blockage on outlet e.g. blocked shower handset.  

Replace the pressure relief disc (not covered by guarantee). 

Water does not 

flow when button 
“B” is pressed. 

Check circuit through solenoid coil.  If defective then replace. 

Check circuit through push button switch.  If defective then replace. 
Power supply not reaching shower. 

Areas do not light 

up when button 
“B”  pressed 

Check power connection to front cover. 
Faulty front cover assembly – replace

.

                                                              

Illumination is limited to around knobs and button. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

Содержание AquaNoir

Страница 1: ...the desired showering temperature Turn clockwise towards the white bands for cooler Turn anti clockwise towards the red bands for warmer 5 When you have finished showering press the start stop button...

Страница 2: ...wrong 1 Self Help Creda After Sales Service What to do if things go wrong 2 Professional Service How your AquaNoir Shower Works Guarantee and Contact Details How to use your AquaNoir Shower Summary P...

Страница 3: ...t is likely that the pressure switch will turn off the power to the heating elements resulting in a cold shower HOW YOUR AquaNoir SHOWER WORKS Diagram10 3 INTRODUCTION If you experience any difficulty...

Страница 4: ...into the unit If top entry is chosen cut away the backplate as shown in Diagram 2a If bottom entry is chosen cut away the walls in the detachable bottom section as shown in Diagram 2b If rear please...

Страница 5: ...first Tighten top screw with head protruding about 10mm from the wall and hook the backplate over the screw head This allows for correct and accurate alignment of your shower before marking and fixing...

Страница 6: ...bber nozzles or soaking in proprietary lime scale remover and rinsing thoroughly before use actual shower handset not necessarily shown NOTE After use it is normal for some water to drip from the show...

Страница 7: ...wer giving a cooler shower or the option of reduced water flow This option is mainly for summer usage and if this is used then knob C must be re adjusted 8 The Cold 1 white band setting will supply wa...

Страница 8: ...ature and water flow can be adjusted by control knob C b Power selection operates in all 3 positions giving a change in water temperature c Check again for leaks and that the holes in the shower hands...