Creda AquaNoir Скачать руководство пользователя страница 3

 

14 

 

 

1.

 

Water is heated instantaneously as it flows 
over the heating elements in the copper 
cylinder (Diagram 9). 

 

2.

 

The heaters are only switched on when 

sufficient water is flowing.                                                                                                
This is done automatically with a switch 
which works on water pressure. 

 

3.

 

The water is turned on and off by the 

solenoid valve

(and Timer PCB on                                                                                                

10.5kW models) 

 built into the shower.                                                                                         

This is switched on when button “B” is 

pressed. 

 

4.

 

The flow of water is automatically held at 
the level set by the user even though the 
supply pressure may vary (see “Effect of 
Other Water Devices on Incoming Water 

Supply”). 

 

5.

 

If the water supply falls below a set limit, 
the pressure switch will operate and 
switch off the power to the elements. (see 

“Effect of Other Water Devices on Incoming Water Supply”). 

 

6.

 

As a further safeguard

, a thermal cut-out switches the power off if the water temperature 

climbs above the set limit.                                                                                                                   
This cut-out, which gives an audible click, may also operate due to residual heat when the shower 

is switched off.  It will reset itself if water is run through the shower for 10 to 20 seconds. 

 

7.

 

The pressure relief device is to safeguard against abnormal pressure conditions, and provides a 

level of appliance protection should an excessive build of pressure occur within the shower. 

 

Effect of Seasonal Incoming Water Temperature Changes 

 

The required water temperature is achieved by adjusting the rate of water flow.  
Diagram 10 shows the principle involved in relating temperature rise to flow 

rate. The higher the water rate the lower the temperature and vice versa.                                               

The temperature of the water supplied from the mains can vary considerably 
throughout the year from 5 to 20°C.                                                                                                                    
This means that in the winter, flow rate will be less than in the summer to 

achieve the same outlet temperature.                                                                                                                                                 

In summer the Medium

 (2 red bands) 

power setting may give adequate hot water.  

In some 

winter

 conditions, it may be necessary to select the 

inner or outer spray pattern

 only of 

your shower handset. This will ensure correct operation of the shower with a slightly lower flow rate. 

 

Effect of Other Water Devices on Incoming Water Supply 

 

Your shower is 

designed to stabilise temperature

 changes caused by water pressure 

fluctuations. These can result from toilets being flushed or taps being turned on and off.                                 
When this happens your showering temperature will be held within a controlled band, provided that 
the minimum pressure required by the shower is maintained. 

 

Your shower requires a minimum running pressure of 69kPa (0.7 bar, 10 psi).                                                 

At pressures above 69kPa (0.7 bar, 10 psi) it will minimise temperature fluctuations as detailed 
above. If the water pressure falls below 69kPa (0.7 bar, 10 psi) it is likely that the pressure switch 
will turn off the power to the heating elements, resulting in a cold shower.  

HOW YOUR 

AquaNoir 

 SHOWER WORKS 

Diagram10 
 

 

INTRODUCTION 

If you experience any difficulty with the installation or operation of your new 

shower, then please refer to the “What to do if things go wrong” section in this 

manual before contacting us. 

 

Thank you for purchasing a quality 

Creda AquaNoir 

shower manufactured in England. 

To enjoy your new shower at its best, please take time to read this manual thoroughly to 

familiarise yourself with all instructions, BEFORE beginning installation. 

Having done so, keep this manual handy for future reference. 

 

The 

Creda AquaNoir 

is an electric shower incorporating our unique 

“Backlit LED light feature”

 with a 

Set and Forget

” function of a push-button start/stop facility which starts the shower at a pre-set 

power and flow rate reducing the amount of adjustment required.  

 

Your shower is designed to stabilise temperature changes caused by water pressure fluctuations.                                          

These can result from toilets being flushed or taps being turned on and off.  
When this happens, your showering temperature will be held within a controlled band, provided that 
the minimum pressure required by the shower is maintained (see “Effect of Other Water Devices”). 

 

 

 

 

1.

 

Your shower has been designed for convenience, economy and safety of use, provided that it is 

installed, used and maintained in good working order and in accordance with our instructions and 
recommendations. 

 

2.

 

All wiring and installation must be supervised by a suitably qualified person. 

 

3.

 

THIS APPLIANCE MUST BE EARTHED. 

 

4.

 

The installation must be in accordance with the current edition of BS.7671 (

the “IEE Wiring

 

Regulations”)

 and “Part P” of the 

“Building Regulations”

 in force at the time of installation. 

Installations outside of England and Wales must also conform to any local regulations in effect. 

This appliance is intended to be permanently connected to the fixed electrical wiring of the mains 

supply with its own dedicated supply. 

 

5.

 

This appliance must 

NOT

 be fitted where it may be subjected to freezing conditions. 

 

 

6.

 

DO NOT

 switch the appliance on if you suspect it of being frozen.                                                             

Wait until you are sure it has thawed out. 

 

 

7.

 

DO NOT

 fit any sort of tap or control on the appliance outlet.                                                                      

The appliance is designed to have an open outlet and should only be used with “Creda” 
recommended fittings. 

 

 

8.

 

The shower handset provided is designed to work with electric showers.                                                  
Only use the manufacturers approved accessories with this shower.

 

 

 

   

       

9.

 

Take care to avoid restricting the outlet of the pressure relief device.                                                                                  
If water is discharged from the pressure relief device, maintenance will be required before the 

appliance can be safely used. 

 

 

10.

 

Isolate the mains electrical and water supply before removing the front cover of the appliance.

 

 

 

IMPORTANT SAFETY INFORMATION 

Содержание AquaNoir

Страница 1: ...the desired showering temperature Turn clockwise towards the white bands for cooler Turn anti clockwise towards the red bands for warmer 5 When you have finished showering press the start stop button...

Страница 2: ...wrong 1 Self Help Creda After Sales Service What to do if things go wrong 2 Professional Service How your AquaNoir Shower Works Guarantee and Contact Details How to use your AquaNoir Shower Summary P...

Страница 3: ...t is likely that the pressure switch will turn off the power to the heating elements resulting in a cold shower HOW YOUR AquaNoir SHOWER WORKS Diagram10 3 INTRODUCTION If you experience any difficulty...

Страница 4: ...into the unit If top entry is chosen cut away the backplate as shown in Diagram 2a If bottom entry is chosen cut away the walls in the detachable bottom section as shown in Diagram 2b If rear please...

Страница 5: ...first Tighten top screw with head protruding about 10mm from the wall and hook the backplate over the screw head This allows for correct and accurate alignment of your shower before marking and fixing...

Страница 6: ...bber nozzles or soaking in proprietary lime scale remover and rinsing thoroughly before use actual shower handset not necessarily shown NOTE After use it is normal for some water to drip from the show...

Страница 7: ...wer giving a cooler shower or the option of reduced water flow This option is mainly for summer usage and if this is used then knob C must be re adjusted 8 The Cold 1 white band setting will supply wa...

Страница 8: ...ature and water flow can be adjusted by control knob C b Power selection operates in all 3 positions giving a change in water temperature c Check again for leaks and that the holes in the shower hands...

Отзывы: