Smart Chain Hoist Reference Manual
Published 4-14-20
VFD SETTINGS
The parameter settings on the Mitsubishi Variable Frequency Drive (VFD) are tailored to make the unit
work effectively with each machine. The
Smart Chain Hoist
uses a different set of VFD parameters
than all of the other Creative Conners, Inc. stock products. Below is a list of the parameters that are
changed from the factory defaults, and what they do. Viewing and changing the parameters is a
straightforward process. On the VFD keypad press the MODE button until a ‘P’ is displayed. Use the
wheel to scroll to the desired parameter number and press the SET button. The display will change
and display a number value. Use the wheel to adjust the value and press SET. To make no change,
simply press the SET button. When all settings are confirmed/adjusted, press the mode button 3 times
until the display shows 0.00. A more detailed explanation of this process can be found at
.
We have designed a few variants of the
Stagehand Pro
and they each need slightly different
parameters to run your
Smart Chain Hoist
efficiently and effectively. To know what
Stagehand Pro
and VFD you have, look at the VFD keypad on the face plate and notice where that keypad is located
on the
Stagehand
itself. If the keypad is square and is located on the bottom right of the faceplate, it is
a
Stagehand Pro 3
with an A800. If the keypad is square on the bottom left of the faceplate it is a
Stagehand Pro 2
with an A800. If it is rectangular and is located on the bottom left of the faceplate, it
is a
Stagehand Pro 2
with an A700.
YOU MUST SET PARAMETER 77 = 2 PRIOR TO BEGINNING THE MANUAL RESTORE
PROCESS
Pr.
No.
Name
Description
Stagehand
Pro 3
Stagehand
Pro 2 A800
Stagehand
Pro 2 A700
1
Maximum frequency
Set the upper limit of the output
frequency.
110
110
110
2
Minimum frequency
Set the lower limit of the output
frequency.
0
0
0
3
Base frequency
Set the frequency at the rated
motor torque. (50Hz/60Hz)
106
106
106
7
Acceleration time
Standard time to accelerate a
movement.
0
0
0
8
Deceleration time
Standard time to decelerate a
movement.
0
0
0
9
Electronic thermal O/L relay
Current rating from the motor
nameplate.
13
13
13
10
DC injection brake operation
Set the frequency at which the
0.5
0.5
0.5
Page 16
Содержание CM Varistar Smart Chain Hoist
Страница 2: ......
Страница 4: ......
Страница 29: ...Smart Chain Hoist Reference Manual Published 4 14 20 DRAWINGS Page 25...
Страница 30: ...Smart Chain Hoist Reference Manual Published 4 14 20 Page 26...
Страница 31: ...Smart Chain Hoist Reference Manual Published 4 14 20 Page 27...