background image

must be on before unit will allow the cooling or freezing mode to acti-
vate.)

4.  Then select refrigeration or freezing mode by pressing the “Press to

Select Function” button until the light under the selection you desire is lit
up. Note: In the cooling mode the LED will read the actual temperature of
the product (The temperature setting is preset to NSF standards and is
not adjustable.) In the freezing mode the LED will read the current time. 

ERROR MESSAGES

“FILTER CLEANING” ALARM
A filter cleaning alarm will activate when the unit is running hot due to insuffi-
cient internal air circulation. When this occurs a “Filtr” message will  appear on
the touchpad LED readout and an intermittent audible tone will also sound to
alert the operator of this condition.
The “Filtr” message will appear when the alarm activates (a beeping sound
every 4-5 seconds). To determine the condition that caused the alarm and cor-
rect problem, see list of conditions below:

• Condition: Filter is dirty and needs to be cleaned

Corrective Action: Clean and replace filter following instructions.

• Condition: Unit is positioned too close to a wall or other objects restricting 

air flow and causing the machine to run at a higher temperature.
Corrective Action: Reposition unit to maximize ventilation space.

• Condition: Filter is not properly installed.

Corrective Action: Properly install filter.

• Condition: Unit has been installed near a heat source, such as a coffee 

machine, ice maker or cold beverage machine which expels hot air from its
vents, causing the machine to run at a high temperature. (Installation near
a heat source should be avoided)
Corrective Action: Reposition unit to maximize ventilation.

“SYSTEM OVER TEMPERATURE” ALARM
• A system over temperature alarm will activate as a safety when the unit has

overheated to protect the compressor.

• The system automatically goes to “OFF” status where the compressor’s oper -

ations are stopped, while augers will keep working to avoid forming ice
blocks.

• When this “Err” message will appear on the touch pad LED readout accompa-

nied by a continuous buzzer sound to alert the operator of this condition.

• When this alarm activates, turn off all switches. Then determine the condition

from the list above.

MG23-2B & ID2.2 TRADITIONAL ROCKER SWITCH MODEL
GUIDE

Important: The mixing parts/auger switch should be on prior
to activating the freezing or refrigeration switches.

(E) activates the mixing parts/spiral auger
(F) activates the freezing of the product
(G) activates the refrigeration of the product
(D) is the main power switch 
FROZEN BEVERAGE - select      (E) and      (F)

Note: There is a 4 minute delay before the compressor starts.

COLD BEVERAGE - select      (E) and      (G)
STANDBY (Night Setting) - select      (E) and      (G)

* Defrost timers are installed in each unit and can be set to automatically

place units in defrost mode and back to frozen mode. All switches must be
on for defrost timer to properly function.

MG23-2B SETTING DEFROST TIMER (& ID2.2 When Equipped)

NOTE: All switches (power, auger, refrigeration and freeze) must be “on” for 
defrost timer to properly function.
• Setting Current Time - Rotate 

the program disc, in the 
direction of the arrows, 
to align the correct time of 
day with the time of day mark

• Setting Defrost Mode - 

Push the switch activator toward
the outer edge of the 
program disc.  Freeze time
is set by pushing the switch actuators toward the center of the time switch.
The light and dark shaded areas of the program disc indicate day and 
night. Each actuator is equivalent to 15 minutes

• The drawing shows a defrost time from 11:00 to 6:15

THE TIMER IS BATTERY BACKED TO PROTECT SETTINGS DURING

POWER FAILURE.  THE BATTERY BACK-UP FEATURE WILL FAIL IF

POWER IS REMOVED FROM THE UNIT FOR MORE THAN 2 WEEKS

PROGRAMMING

G23-2B ELECTRONIC MODEL GUIDE:

MAIN POWER SWITCH:

1.  Turns unit ON.
2.  Selects 12/24 time or FÞ/CÞ temperature display when turned ON 

while simultaneously depressing the auger button.

3.  Sets current time when turned ON while simultaneously depressing 

the “Mode/Press To Select Function” button.

AUGER ON/OFF BUTTON:

1.  Turns auger ON and OFF when main power switch is ON.
2.  Must be ON to permit defrost time to be reset.
3.  Must be ON to activate the “Mode/Press To Select Function” button

to 

select manual “OFF”, “FREEZE” or “COOLING” functions. 

MODE/PRESS TO SELECT FUNCTION BUTTON:

1.  Use to manually select “OFF”, “FREEZE” or “COOLING” functions  

when auger is turned ON.

2,  Accesses defrost timer reset mode when depressed for an extended 

period when auger is turned ON.

3.  Locks in hours, minutes and final time settings after they are reset 

using the “Auto Timer” button.

4.  Does not function when light on “Auto Timer” button is illuminated.

“AUTO TIMER” BUTTON:

1.  Turns auto defrost mode ON or OFF (light on switch indicates when

auto defrost mode is activated).

2,  Used to adjust the hours and minutes settings when readjusting 

current time or auto defrost timer.

ENTER TIME PROGRAMMING ON INITIAL INSTALLATION OR IN THE
EVENT OF A TIME CHANGE:

1.  Turn OFF power switch.
2.  While pressing left “Press to Select Function” button, turn ON power 

switch while continuing to hold the “Press To Select Function” button 
until the display illuminates (hour digits will start to blink).

3.  First set hour by pressing the “Auto Timer” clock button until the 

appropriate hour is shown.

Note: When using a 12 hour clock the time is P.M. when the dot at the bot-
tom right corner of the LED is lit; when dot is not lit it is A.M.)

4.  To set the minutes press the left “Press To Select Function” button, 

then press the “Auto Timer” clock button until the appropriate minutes
are set.

5.  To save your settings press the “Press To Select Function” button

one more  time.

G23-2B SETTING DEFROST TIMER (Night Setting):

1.  Turn the power switch on.
2.  Then press “Auger ON/OFF” button on for the side you are setting.
3.  Then press and hold the “Press to Select Function” button until you

hear a long beep and the LED and clock light begins to blink.

4.  Press the “Auto Timer” clock button to set the hour you want it to turn

to refrigeration mode and then press “Press to Select Function” to
save the setting.

5.  Then press the “Auto Timer” clock to set the minutes to complete

time 
setting that you want it to turn to refrigeration mode. Then press the
“Press to Select Function” button to save the setting.

6.  Proceed to setting the time you want the machine to turn to freezing

mode by following steps 4 and 5 above. Then press the “Press to
Select Function” button to save the time settings for freeze mode.

Note: Once the settings have been saved, the unit will save the settings,
even when the power switch is turned off.

When the light on the “Auto Timer” clock button is “on”, the defrost timer is 
activated. To turn off the defrost timer, press the clock buttons until the
lights on the clock buttons turn off.

G23-2B - TO OPERATE IN AUTOMATIC MODE (WITH DEFROST TIMER 
ACTIVATED)

1.  Turn power switch on and wait for LED to light up.
2.  To operate in defrost mode the light on the “Auto Timer” clock button

should be illuminated.

3.  If it is not, press the “Auto Timer” clock button

to turn on automatic mode.

G23-2B OPERATE IN MANUAL MODE (WITHOUT
DEFROST TIMER ACTIVAT -
ED)

1.  Turn power switch on

and wait for LED to light
up.

2.  Make sure clock button

is off (LED light on clock
button should not be lit
up).

3.  First turn auger on by

pressing “Auger
ON/OFF” button until it
beeps. (Note: The auger

-To access the operating panel, open the cover on the right side
of the unit.

To access the control panel, open the cover on the right side of the unit