PUT ON BOWL SEAL AND SHAFT SEAL
• Moisten bowl seal (T) with water

and put back on

• Check for wear of bell shaped rubber 

shaft seal (see below ) replace if needed

• 

Lubricate inside of bell shaped shaft 
seal (X) with food grade lubricant.

Put 

back seal making sure flared side faces 
the cylinder

10

PUT ON GEAR RING/AUGER ASSEMBLY
• Put gear ring/auger assembly (U) 

back in position

• Secure parts in place by screwing on 

the bolt (S) counterclockwise

11

PUT ON BOWL
• Lightly moisten rear inner part of bowl 

with food grade lubricant

• Position bowl into place making sure 

it has a tight hold on the bowl seal

• 

• Be sure bowl corners fit on outside edge of the top tray piece. The

lid cover will not fit properly if the bowl is not correctly positioned.

12

SECURE BOWL WITH KNOBS 
Keep bowl lifted until the hole in lower bowl
edge is aligned with hole in front panel then
tightly screw on the knobs (P) without exerting
excessive pressure to avoid cracking the bowl

13

REASSEMBLE DISPENSING VALVE

• Lubricate o-rings with food grade 

lubricant and place o-rings on valve

• Place spring over valve stem
• While pushing up on valve, insert 

metal bar on handle under hook on valve

• Slide valve back into position until it 

completely snaps into place

• Reassemble the handle (B) with the rele-

vant pin (G ) (See #5).

14

REASSEMBLE MIXING ROD
• Reassemble mixing rod (O) so that 

its gears are aligned with the lower 
gear ring

• Insert front pin into position at 

front of bowl

15

INSTALL DRIP TRAY
•  Reinstall drip tray, (AA) making sure that

the condensation drainage tube (AB) is 
reinserted into its correct fixed position 
allowing it to drain into the tray

• Plug unit into appropriate power supply

16

SANITIZING UNIT

• Fill bowl with a mix of water and sanitizing solution
• Turn auger on for 10 minutes to sanitize all parts
• Turn off auger
• Drain bowl through dispensing valve
• Unscrew two knobs and lower bowl to drain out remaining solution
• Clean tray underneath bowl and lubricate rear bowl seal
• Reattach bowl
• Screw knobs back on
• Disconnect lamp cover from power.  With clean cloth wash 

underside of lamp cover with warm water and mild detergent.  
Allow to air dry and wipe with cloth that has been dipped in 
sanitizing mixture

CAUTION: MAKE SURE LAMP COVER HAS BEEN DISCONNECTED FROM  POWER.

1

TURN OFF ALL SWITCHES, EMPTY BOWL 
& UNPLUG UNIT

• Turn off refrigeration      /       and 

/      freezing switches and empty the 

bowls of their remaining product

• Turn off auger switches and power switch          
• Unplug the unit

2

REMOVE MIXING ROD

Pull out the mixing rod (O) by 
pushing it slightly backwards 
to remove it from its position

3

REMOVE KNOBS SECURING BOWL - 
DRAIN EXCESS PRODUCT

• Unscrew and remove the two knobs (P)
• Then lower the bowl to drain out 

any remaining product through the 
dispensing valve (l)

4

REMOVE BOWLS 
Remove bowl by pulling it outwards,
lightly tapping the back of bowl so 
it comes out of position or by applying 
slight downward pressure to the top front

edge of the bowl.

5

REMOVE DISPENSING VALVE

• Remove the pin (G) and slide the 

handle out from it’s seat. 

• Simultaneously apply pressure to the 

securing tabs, lift the dispensing valve 
out of its position. 

• Disassemble remaining valve assembly 

parts

6

REMOVE O-RINGS FROM DISPENSING VALVE

• Pinch o-ring between thumb 

and index finger

• Squeeze and push o-ring out 

of the groove

• Roll o-ring out of the groove with 

your other thumb

7

REMOVE MIXING UNIT PARTS & DRIP TRAY
• Unscrew bolt (S) clockwise
• Pull off auger and gear ring assembly (U)
• Remove bowl seal (T) and bell shaped shaft 

seal (X)

• Remove drip tray by lifting up the front edge, 

while lowering the rear edge and pulling
it towards you

8

CLEAN ALL PARTS
• Thoroughly clean all parts removed 

above as well as the base (Y) and 
evaporator (Z).  

• Wash with warm water using 

a mild dish detergent and rinse 
thoroughly with clean water.  

Allow to air dry.

CAUTION:  DO NOT USE ABRASIVE CLEANERS OR SCRUB PADS.

ABRASIVES WILL SCRATCH PLASTIC PARTS AND OTHER FINISHES.