background image

4

Adjust the metal supports or wedges until the shafts of 

the pump and driver are level. Check the coupling faces, 

as well as the suction and discharge flanges of the pump 

for horizontal or vertical position by means of a level. 

Correct the positions, if necessary, by adjusting the 

supports or wedges under the base plate, as required.

NOTE:

 A flexible coupling should not be used to 

compensate for misalignment of the pump and driver 

shafts. The purpose of the flexible coupling is to 

compensate for temperature changes and to permit end 

movement of the shafts without interference with each 

other, while transmitting power from the driver to the pump.

CAUTION! - Remove and lock out power to 

driver

.

3. FIELD ALIGNMENT

The faces of the coupling halves should be spaced far 

enough apart so that they cannot strike each other when 

the driver rotor is moved toward the pump. The necessary 

tools for checking the alignment of a flexible coupling are a 

straight edge and a taper gauge or a set of feeler gauges.

NOTE:

 In most cases where extreme accuracy is 

necessary, a dial indicator may be used to align coupling.

Angular alignment check is made by inserting a taper 

gauge or feelers between the coupling faces at 90-degree 

intervals around the coupling. The unit will be in angular 

alignment when the coupling faces are exactly the same 

distance apart at all points. (See Figure 3).

Parallel alignment check is made by placing a straight 

edge across both coupling rims at the top, bottom and 

at both sides. The unit will be in parallel alignment when 

the straight edge rests evenly on the coupling rim at all 

positions. Allowance may be necessary for temperature 

changes and for coupling halves that are not of the same 

outside diameter. Care must be taken to have the straight 

edge parallel to the axis of the shafts. Correction for 

Angular and Parallel Misalignment is made by adjusting 

the shims under the driver. After each change, it is 

necessary to recheck the alignment of the coupling halves, 

as adjustment in one direction may disturb adjustments 

already made in another direction.

The permissible amount of coupling misalignment will vary 

with the type of pump and driver, but should be limited to 

approximately .002 inches per inch of shaft diameter when 

final adjustment is made. When the units are lined up cold, 

it is necessary to make allowance for the vertical rise of 

the driver caused by heating when in operation. When the 

preliminary alignment has been completed the foundation, 

bolts should be tightened evenly, but not too firmly.

WARNING - Coupling guards must be used to 

avoid serious injury to operating personnel.

Figure 3

PERFECT

ALIGNMENT

PARALLEL

MISALIGNMENT

ANGULAR

MISALIGNMENT

Содержание WEINMAN 100

Страница 1: ...stant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Brampton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 096882 Rev H Sections 320 100 200 300 and 500 ...

Страница 2: ...arge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO N...

Страница 3: ...rvice Center check your Weinman representative or Crane Pumps Systems Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Brampton Ontario 905 457 6223 B INSTALLATION 1 FOUNDATION The pump foundation should be sufficiently substantial to form a level rigid support for the combined weight of the pump and driver and maintain alignment of the installed unit Found...

Страница 4: ...g The unit will be in angular alignment when the coupling faces are exactly the same distance apart at all points See Figure 3 Parallel alignment check is made by placing a straight edge across both coupling rims at the top bottom and at both sides The unit will be in parallel alignment when the straight edge rests evenly on the coupling rim at all positions Allowance may be necessary for temperat...

Страница 5: ...any high points in the line which will form air pockets the pump will not operate properly 3 If conditions require the use of a foot valve and strainer the flow area of the foot valve should be from 1 1 2 to 2 times the area of the suction pipe and the strainer should have a free opening area equal to 3 to 4 times the area of suction pipe Otherwise excessive frictional loss will result 4 If a gate...

Страница 6: ...irable that the dis charge line be provided with a flexible connection TDV DESIGN AND OPERATION The principle of operation for the TDV valve is extremely simple When in the open position the clapper swings out of the flow If the flow stops the spring allows the clapper to close When closing the valve a final bumping action with a wrench gives the final positive seal closure TDV MAINTENANCE The TDV...

Страница 7: ...vement by opening and closing the clapper by hand 7 If movement is free complete the valve assembly 6 WIRING WARNING DO NOT START PUMP UNTIL IT HAS BEEN FILLED WITH WATER 1 Motor wiring should conform to national and local electrical codes 2 Use wire of adequate size to prevent voltage drop 3 Pump should be on a branch or separate circuit fused or circuit breaker protected with a manual disconnect...

Страница 8: ...8 PIPING Right Wrong FIGURE 5 ...

Страница 9: ... priming is accomplished by completely filling the suction piping and pump casing with the liquid to be pumped This can be done by removing the air vent valve or plug at the top of the pump casing and inserting a pipe nipple in the orifice with an appropriate increaser to accommodate a hose connection A priming line can also be inserted in the discharge piping between the check valve and the pump ...

Страница 10: ...ould be clean and polished smooth Slide seal body on shaft washer end first and seat firmly A sleeve as shown in Fig 6 will facilitate this operation and prevent the rubber driving ring from pulling out of place as the seal body is slid along the shaft Assembly of impeller automatically sets seal in proper position Make sure at all times and particularly before final assembly that both sealing fac...

Страница 11: ...diment When installing in pond or lake support the suction line so that it will be submerged in water but nut imbedded in mud or sediment A strainer with greater screen area may be required d Add sufficient pipe to keep the submerged end well below the water surface e If caused by suction pipe friction increase the size of the pipe otherwise move the pump closer to the water level f Order replacem...

Страница 12: ...A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty If ...

Отзывы: