background image

3

A - GENERAL INFORMATION

 

TO THE PURCHASER:

Congratulations! You are the owner of one of the finest 

pumps on the market today. These pumps are products 

engineered and manufactured of high quality components. 

With years of pump building experience along with a 

continuing quality assurance program combine to produce 

a pump which will stand up to the toughest applications.

Check local codes and requirements before installation. 

Servicing should be performed by knowledgeable pump 

service contractors or authorized service stations.

RECEIVING:

Upon receiving the pump, it should be inspected for 

damage or shortages. If damage has occurred, file a claim 

immediately with the company that delivered the pump. 

If the manual is removed from the crating, do not lose or 

misplace. 

STORAGE:

Short Term - 

Pumps are manufactured for efficient 

performance following long inoperative periods in storage.

For best results, pumps can be retained in storage, as 

factory assembled, in a dry atmosphere with constant 

temperatures for up to six (6) months.

Long Term -

 Any length of time exceeding six (6) months, 

but not more than twenty four (24) months. The units 

should be stored in a temperature controlled area, a roofed 

over walled enclosure that provides protection from the 

elements (rain, snow, wind blown dust, etc..), and whose 

temperature can be maintained b40 deg. F and 

+120 deg. F. Pump should be stored in its original shipping 

container and before initial start up, rotate impeller by hand 

to assure seal and impeller rotate freely. 

SERVICE CENTERS:

For the location of the nearest Weinman Service Center, 

check your Weinman representative or Crane Pumps & 

Systems Service Department in Piqua, Ohio, telephone 

(937) 778-8947 or Crane Pumps & Systems Canada, Inc., 

Brampton, Ontario, (905) 457-6223.

B - INSTALLATION

1. FOUNDATION

The pump foundation should be sufficiently substantial 

to form a level, rigid support for the combined weight 

of the pump and driver and maintain alignment of the 

installed unit. Foundation bolts, of the proper size, should 

be imbedded in the concrete. A pipe sleeve, about 2½” 

diameters larger than the bolt, should be used to allow for 

final positioning of the bolts. See Figure 1.

2. MOUNTING:

Position the unit on the foundation and level the pump 

base, using metal shims, so that the pump shaft is in 

vertical alignment and the pump suction and discharge 

flanges are level in both vertical and horizontal plane. Base 

may be grouted following alignment. Use a plumb line from 

floor above to establish centerline of pump and flexible 

drive shaft and bearings.

COMMON BASE PLATE:

Pumps and drivers that are received from the factory 

with both machines mounted on a common base plate, 

were accurately aligned before shipment. All baseplates 

are flexible to some extent and, therefore, must not be 

relied upon to maintain the factory alignment. Preliminary 

alignment is necessary after the complete unit has been 

leveled on the foundation, and again, after the unit is 

piped, and rechecked periodically as outlined in the 

following paragraphs.

 

Position unit on foundation and level the base plate, 

using rectangular metal blocks and shims, or wedges 

having a small taper as shown in Figure 2.  A gap of 3/4” 

to 1½” should be allowed between the base plate and 

foundation for grouting.

Figure 1. Foundation Bolt 

Location and Anchorage

Figure 2. Adjusting Wedges for Mounting

Содержание WEINMAN 100

Страница 1: ...stant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Brampton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 096882 Rev H Sections 320 100 200 300 and 500 ...

Страница 2: ...arge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO N...

Страница 3: ...rvice Center check your Weinman representative or Crane Pumps Systems Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Brampton Ontario 905 457 6223 B INSTALLATION 1 FOUNDATION The pump foundation should be sufficiently substantial to form a level rigid support for the combined weight of the pump and driver and maintain alignment of the installed unit Found...

Страница 4: ...g The unit will be in angular alignment when the coupling faces are exactly the same distance apart at all points See Figure 3 Parallel alignment check is made by placing a straight edge across both coupling rims at the top bottom and at both sides The unit will be in parallel alignment when the straight edge rests evenly on the coupling rim at all positions Allowance may be necessary for temperat...

Страница 5: ...any high points in the line which will form air pockets the pump will not operate properly 3 If conditions require the use of a foot valve and strainer the flow area of the foot valve should be from 1 1 2 to 2 times the area of the suction pipe and the strainer should have a free opening area equal to 3 to 4 times the area of suction pipe Otherwise excessive frictional loss will result 4 If a gate...

Страница 6: ...irable that the dis charge line be provided with a flexible connection TDV DESIGN AND OPERATION The principle of operation for the TDV valve is extremely simple When in the open position the clapper swings out of the flow If the flow stops the spring allows the clapper to close When closing the valve a final bumping action with a wrench gives the final positive seal closure TDV MAINTENANCE The TDV...

Страница 7: ...vement by opening and closing the clapper by hand 7 If movement is free complete the valve assembly 6 WIRING WARNING DO NOT START PUMP UNTIL IT HAS BEEN FILLED WITH WATER 1 Motor wiring should conform to national and local electrical codes 2 Use wire of adequate size to prevent voltage drop 3 Pump should be on a branch or separate circuit fused or circuit breaker protected with a manual disconnect...

Страница 8: ...8 PIPING Right Wrong FIGURE 5 ...

Страница 9: ... priming is accomplished by completely filling the suction piping and pump casing with the liquid to be pumped This can be done by removing the air vent valve or plug at the top of the pump casing and inserting a pipe nipple in the orifice with an appropriate increaser to accommodate a hose connection A priming line can also be inserted in the discharge piping between the check valve and the pump ...

Страница 10: ...ould be clean and polished smooth Slide seal body on shaft washer end first and seat firmly A sleeve as shown in Fig 6 will facilitate this operation and prevent the rubber driving ring from pulling out of place as the seal body is slid along the shaft Assembly of impeller automatically sets seal in proper position Make sure at all times and particularly before final assembly that both sealing fac...

Страница 11: ...diment When installing in pond or lake support the suction line so that it will be submerged in water but nut imbedded in mud or sediment A strainer with greater screen area may be required d Add sufficient pipe to keep the submerged end well below the water surface e If caused by suction pipe friction increase the size of the pipe otherwise move the pump closer to the water level f Order replacem...

Страница 12: ...A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty If ...

Отзывы: