background image

3

Please Read This Before Installing Or Operating Pump. 
This information is provided for 

SAFETY and to PREVENT 

EQUIPMENT PROBLEMS

. To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury or Indicates factors concerned with 
assembly, installation, operation, or maintenance which 
could result in damage to the machine or equipment if 
ignored.

CAUTION !

 Warns about hazards that can or will cause minor 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only qualifi ed personnel should install, operate and repair 
pump. Any wiring of pumps should be performed by a qualifi ed 
electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 
accordance with the National Electric Code (NEC) or the 
Canadian Electrical Code (CEC) and all applicable state, 
province, local codes and ordinances. 

WARNING! -

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 
handling or servicing. Lock out power and tag.

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 
and seal failure on any pump, and on end 
suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 
pressures. It is recommended that a high case temperature 
switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

CAUTION! 

Pumps build up heat and pressure 

during operation-allow time for pumps to cool 
before handling or servicing. 

WARNING!

 - 

DO NOT

 pump hazardous materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

Do not block or restrict discharge hose, as discharge 
hose may whip under pressure. 

WARNING! - DO NOT

 wear loose clothing that may 

become entangled in the impeller or other moving parts. 

WARNING! - 

Keep clear of suction and discharge 

openings. 

DO NOT

 insert fi ngers in pump with power 

connected.

Always wear eye protection when working on pumps.

Make sure lifting handles are securely fastened each 
time before lifting. 

DO NOT

 operate pump without 

safety devices in place. Always replace safety devices 
that have been removed during service or repair. 
Secure the pump in its operating position so it can not 
tip over, fall or slide.

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor 
to overheat.

DO NOT

 remove cord and strain relief. Do not connect 

conduit to pump.

WARNING!

 Cable should be protected at all times to 

avoid punctures, cut, bruises and abrasions - inspect 
frequently. Never handle connected power cords with 
wet hands.

WARNING!

 To reduce risk of electrical shock, all wiring 

and junction connections should be made per the NEC 
or CEC and applicable state or province and local 
codes. Requirements may vary depending on usage 
and location.

WARNING!

 Submersible Pumps are not approved for 

use in swimming pools, recreational water installations, 
decorative fountains or any installation where human 
contact with the pumped fl uid is common.

WARNING! 

Products Returned Must Be Cleaned, 

Sanitized, Or Decontaminated As Necessary Prior 
To Shipment, To Insure That Employees Will Not Be 
Exposed To Health Hazards In Handling Said Material. 
All Applicable Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fi tted pumps may 
contain lead levels higher than considered safe for 
potable water systems. Lead is known to cause cancer 
and birth defects or other reproductive harm. Various 
government agencies have determined that leaded 
copper alloys should not be used in potable water 
applications. For non-leaded copper alloy materials of 
construction, please contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a 
failure to observe these safety precautions, misuse or 
abuse of pumps or equipment.

SAFETY FIRST!

Hazardous fl uids can 
cause fi re or explo-
sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous fl uids can Hazard-
ous pressure, eruptions or ex-
plosions could cause personal 
injury or property damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Содержание PROSSER 4SED-L Series

Страница 1: ...ct improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 097251 Rev G Series 4SED L 3 10HP 1750RPM DISCONTINUED Parts may NOT be a...

Страница 2: ...0 14 EXPLODED VIEW Fig 11 15 PARTS LIST 16 17 RETURNED GOODS POLICY 19 WARRANT START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT see parts list PRESSURE GAUGE KIT see parts list Other brand and product names are trademarks or registered trademarks of their respective holders PROSSER is a registered trademark of Crane Pumps Sy...

Страница 3: ...ert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers ...

Страница 4: ...una N Hardware 300 series stainless steel CORD ENTRY 50 Ft 15 2m Cord Epoxy sealed housing with secondary pressure grommet for sealing and strain relief SPEED 1750RPM 60Hz nominal UPPER BEARING Design Single Row Ball Oil Lubricated Load Radial LOWER BEARING Design Double Row Ball Oil Lubricated Load Radial Thrust MOTOR Design NEMA L Single phase NEMA B Three Phase Torque Curve Oil Filled Squirrel ...

Страница 5: ... Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada in Brampton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location Water feeding and discharging for construction and civil works Water supply and sewage works Various kinds of industrial facilities Housing and building facilities The pump can be used at almost all places but avoid con tinuous short water operation at...

Страница 6: ...ATINGS Volts Continuous Amperes Inrush Amperes 110 120 3 00 30 0 220 240 1 50 15 0 440 480 0 75 7 5 600 0 60 6 0 C 3 4 Wire Size Consult a qualified electrician for proper wire size if additional power cable is required See table for electrical information SECTION D START UP OPERATION D 1 Check Voltage and Phase Before operating pump compare the voltage and phase information stamped on the pump id...

Страница 7: ...otor housing 2 but DO NOT disconnect conduit box wiring from motor leads With a flashlight visually inspect the oil in the motor housing 2 to make sure it is clean clear and that oil level is above all internal componentry Seal Chamber Place pump on its side with pipe plug 22 downward remove pipe plug 22 and drain oil from the seal chamber If the oil is found to contain considerable water or other...

Страница 8: ...t lb Check for free rotation of motor and impeller F 3 Motor and Bearing Service F 3 1 Disassembly and Inspection To examine or replace the motor 1 and bearings 3 and 47 disassemble pump volute and impeller as outlined in paragraph F 2 1 and disassemble seal plate and shaft seal as outlined in paragraph F 4 1 Drain oil from motor as out lined in paragraph F 1 3 Position unit upright using blocks t...

Страница 9: ...hes If the end play is within these tolerances proceed with reassembly If the end play is not within the above listed tolerances the motor upper end bell must be disassembled and sufficient 010 shims 9 must be added or removed as required Reassemble and recheck again for the required listed end play tolerance F 4 Shaft Seal and Diaphragm Service Important Handle seal parts with extreme care do not...

Страница 10: ...nd not cocked or resting on bellows tail Re oil shaft and lightly oil in ner surface of outboard rotating member 46B With tail section toward bearing bracket 21 slide rotating member 46B onto shaft with seal pusher until retainer engag es spring 46C and spring is compressed slightly Make sure spring 46C is properly engaged in both retainers Slide seal plate 25 over shaft onto bearing bracket 21 be...

Страница 11: ... White 3 9 T4 T5 T6 Together THREE PHASE 480 600 VOLT AC THREE PHASE 480 600 VOLT AC Power Cable Power Cable Motor Lead Number Motor Lead Number Green Ground Green Black 1 Red 2 White 3 T4 T7 Together T5 T8 Together T6 T9 Together MOISTURE AND TEMPERATURE SENSORS MOISTURE AND TEMPERATURE SENSORS Control Cable Control Cable Lead Number Lead Number Green Ground Green Black P1 Temperature Sensor Whit...

Страница 12: ...e design configuration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which repre sent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for order ing and obtaining information G 4 SERIAL NUMBER The serial number block will consist of a six digit number which is specif...

Страница 13: ...eller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as...

Страница 14: ...14 FIGURE 10 ...

Страница 15: ...15 FIGURE 11 ...

Страница 16: ...n Ring 2 071431A Friction Ring For 5HP 1PH 10HP ONLY 10d 1 051452 Grommet 1 071430A Grommet For 5HP 1PH 10HP ONLY 10e 1 Control Cable Not Sold Separately 10f 1 051448 Gland Nut 10g 2 021531 Friction Ring 10h 1 066871 Grommet 10J 1 030169 Ground Screw 10 32 x 5 8 Lg Stainless 11 1 051937 Square Ring 12 5 016406 Connector 5 030148 Connector For 5HP 1PH 10HP ONLY 13 2 5 Gal 029034 Oil Motor Housing 3...

Страница 17: ... 001162 Shim 031 x 2 O D Bearing 32 1 022873 Diaphragm 33 1 051467 Shaft Key 1 4 Sq x 1 1 4 lg Stainless 34 1 037116 Cap Screw 1 2 13 x 1 1 4 lg w nyloc stainless 35 1 070089 Washer 562 ID x 1 625 OD x 187 THK Stainless 36 2 001348 Shim 031 x 1 5 O D Impeller 37 2 001349 Shim 010 x 1 5 O D Impeller 39 2 036803 Soc Hd Cap Screw 1 4 20 x 3 4 lg Stainless 41 1 036852 Gasket 42 1 056668 Square Ring 43...

Страница 18: ...rformance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING FROM SYSTEMS ANALYSES AND EVALUAT...

Страница 19: ...ent To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pump...

Страница 20: ...Does impeller turn freely by hand Yes No Condition of equipment Good Fair Poor Condition of cable jacket Good Fair Poor Resistance of cable jacket Good Fair Poor Resistance of cable and pump motor measured at pump control Red Black Ohms Red White Ohms White Black Ohms Resistance of Ground Circuit between Control Panel and outside of pump Ohms MEG Ohms check of insulation Red to Ground White to Gro...

Страница 21: ...tion Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks Does check valve s operate properly Flow Does station appear to operate at proper rate Pump down time Noise level High Medium Low Comments Equipment difficulties during start up MANUALS Has opera...

Страница 22: ...22 Notes ...

Отзывы: