background image

 

 

8

 

 

MAINTENANCE 
 
CAUTION:  
Always be sure that the appliance is unplugged and switched OFF 
before cleaning or attempting to store the item. NEVER PLUG OR 
UNPLUG UNIT WITH WET HANDS. 
 
DO NOT leave water in water tank or water basin when unit is not 
in use as it may result in the build up of mineral deposits and 
bacteria that can inhibit the output efficiency of the humidifier.  
 
PLEASE NOTE that if water remains in the water tank for more 
than a day or two, bacterial growth is possible.   
 
ALWAYS use fresh cool water when using unit. 
 
NOTE: 

 When removing water tank, water may accumulate under vapor lid and on the 

bottom of the water tank.  It is recommended to have a dry cloth ready to dry wet 
surfaces. 
 

DISINFECTING THE WATER TANK AND WATER BASIN 
 

1.

 

Fill water tank with 1 teaspoon of household bleach or white vinegar in 1 gallon 
of water.  Let stand twenty minutes, shaking vigorously with two hands every 
few minutes, drain and rinse with clean water until the bleach or vinegar smell is 
gone.  Dry with a clean cloth or paper towel. 

2.

 

Wipe the water basin with a soft cloth dampened in the bleach or white vinegar 
and water solution.  Rinse the water basin with cool water to remove any smell.  
DO NOT IMMERSE WATER BASIN IN WATER. 

3.

 

Wipe all exteriors surfaces of the base with a soft, dry cloth.  Do not immerse the 
base in water or use water to clean the base.  An electric shock may result or the 
humidifier may be damaged. 

 

GENERAL MAINTENANCE AND CLEANING  

Before any cleaning operation, switch the humidifier off and unplug it.  

 

1.

 

Always unplug the unit before cleaning. 

2.

 

The humidifier must be drained and cleaned before storing. 

3.

 

Once unplugged the exterior of the unit may be cleaned by wiping with a dry cloth.

 

Caution:

 The ON/OFF switch must be thoroughly dry before unit is again plugged 

into power source. 

4.

 

There  may  be  some  lime  deposits  in  the  nebulizer,  particular  in  areas  with  hard 
water. Overcome this drawback by cleaning the nebulizer with water and vinegar on 
a soft cloth regularly, as follows:  

A.

 

Dampen  a  cloth  with  a  few  drops  of  white  vinegar  or  bleach  water  solution 
and wipe the nebulizer gently, until the lime deposits disappear completely.  

B.

 

Rub down gently with a dry cloth and remove remains of humidity.  

C.

 

Do not rub the nebulizer with solid objects.  

D.

 

Do not clean with chemical products. 

 

Содержание EE-864

Страница 1: ...2 1 GALLON 7 56 LITER ULTRASONIC HUMIDIFIER MODEL EE 864 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS APPLIANCE ...

Страница 2: ...ety Instructions P 2 General Safety Instructions P 3 List of Main Parts P 4 Tech Specifications Contents of Packaging P 5 Operation and Use P 5 7 Maintenance P 8 9 Trouble Shooting Service Center Information P 10 Warranty Information P 11 Warranty Card P 12 ...

Страница 3: ...es 6 Use only a 110 120VAC outlet ALWAYS plug and unplug unit with dry hands 7 Never operate the unit with a damaged cord or plug 8 Always place the unit on a smooth lint free non metallic waterproof level surface and away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move...

Страница 4: ...d must be arranged so that it will not drape over the countertop or tabletop where it can be pulled on by children or tripped over accidentally ELECTRIC POWER If electric circuit is overloaded with other appliances your appliances may not operate properly The appliances should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This appliance has a polarized...

Страница 5: ...Power Light Fig 1 Fig 2 Top of Water Tank 6 Vapor Outlet Channel 7 Water Tank Handle Fig 2 Fig 3 Water Basin 8 Nebulizer 9 Vaporization Chamber 10 Fan Vent 11 Valve Opener 12 Water Level Sensor Fig 3 Fig 4 Bottom of Water Tank 13 Water Tank Valve 14 Water Tank Cap 15 Vapor Outlet Channel Fig 4 Fig 5 Water Tank Lid 16 Water Tank Lid 17 Vapor Output Slot Fig 5 ...

Страница 6: ...rface for best performance This is to help disperse the mist in the air and prevent it from being knocked or tipped over CHECK WATER LEVEL SENSOR Make sure that the water level sensor is secured properly Refer to cleaning and maintaining water level sensor on page 9 for instructions on how to assemble water level sensor CHECK FAN VENT This fan vent is located on the bottom of the humidifier The pu...

Страница 7: ...led water DO NOT use hot water Use cool tap water DO NOT add any medication to other additives to the water DO NOT pour water into Vapor Outlet Channel part 6 Fig 2 on page 4 Fig 7 4 Replace the water tank cap aligning the threads on the tank with the threads on the cap and turn it clockwise See Fig 8 Fig 8 5 Turn the tank over holding one hand by the top handle and another hand under tank Place f...

Страница 8: ...AN ELEVATED NON METALLIC LINT FREE WATERPROOF LEVEL SURFACE FOR BEST PERFORMANCE Adjust the vapor control so that the vapor rises up and gets absorbed by the room air Do not turn on too high output as the vapor cannot be absorbed by the air and accumulates on the surface around the humidifier If the humidifier is placed near a fan or air conditioning outlet the vapor may be forced down by the fore...

Страница 9: ...ith a soft cloth dampened in the bleach or white vinegar and water solution Rinse the water basin with cool water to remove any smell DO NOT IMMERSE WATER BASIN IN WATER 3 Wipe all exteriors surfaces of the base with a soft dry cloth Do not immerse the base in water or use water to clean the base An electric shock may result or the humidifier may be damaged GENERAL MAINTENANCE AND CLEANING Before ...

Страница 10: ... on the pin by pulling it up see Fig 12 Remove the water float and cap and clean by wiping the parts with a soft damp cloth Replace the parts by first putting the water float onto the pin and then pressing the plastic cap on the end of the pin to secure the float see Fig 13 Do not use excessive force Fig 11 Fig 12 Fig 13 STORING YOUR HUMIDIFIER Allow the appliance to dry completely before storing ...

Страница 11: ... there is water in the tank Check for possible lime deposits on the water level float or the nebulizer Make sure that nothing blocks the vapor output slot Check that the air vent on bottom of humidifier is not blocked Empty the humidifier and rinse the water basin with cool tap water and allow to dry for 15 to 30 min White dust appears and settles outside the humidifier Area tap water may have too...

Страница 12: ...ions provided with the product This warranty does not apply to normal wear and tear as well as commercial use The warranty is non transferable and applies only to the original purchase and does not extend to subsequent owners of the product Liability under this warranty is limited to repair or replacement In no event shall liability exceed the purchase price paid by the purchaser of the product Un...

Страница 13: ...ut the warranty card and include it with a copy of the dated sales receipt In return you will receive your repaired item or a new product at the service center s discretion This Ultrasonic Humidifier was tested and meets our stringent quality standards This product is warranted to be free from manufacturing defects in original materials including original parts and workmanship for 1 year with proo...

Страница 14: ...13 ...

Отзывы: