7

7.

 

The Power Light will turn on red. In a few seconds it will switch to green, indicating 
that enough water is in the water basin, and vapor will start emitting through the 
openings at water tank lid.  

 

 

8.

 

Use the regulator control knob to adjust the intensity of the vapor output. Turning 
the knob clockwise will increase the moisture output, turning the knob 
counterclockwise with reduce the moisture output. 

 

 

9.

 

When the humidifier runs out of water the power light will turn red, and the mist 
output will stop. This is a safety feature to prevent the humidifier from possibly over 
heating and damaging the nebulizer. This safety feature uses a water level sensor to 
stop the nebulizer once the water level sinks below the required level in the water 
basin.  

Please note that the RED Power Light on the humidifier body will stay on. The 

(red) light signal indicates that the humidifier is turned on and needs to be refilled.  

Turn the humidifier off and unplug before removing and refilling the water tank.

 

 

 

                      

 

SET THE CORRECT HUMIDITY OUTPUT 

 
ALWAYS PLACE THE HUMIDIFIER ON AN ELEVATED NON-METALLIC LINT FREE, 
WATERPROOF, LEVEL SURFACE FOR BEST PERFORMANCE. 

 

Adjust the vapor control so that the 
vapor rises up and gets absorbed by the 
room air. Do not turn on too high output 
as the vapor cannot be absorbed by the 
air and accumulates on the surface 
around the humidifier. 
If the humidifier is placed near a fan or 
air conditioning outlet the vapor may be 
forced down by the foreign air stream. 
Change the location of the humidifier or 
reduce the output of the other room 
conditioning appliances.

 

 

 

 

 

 

correct 

wrong 

 

 

 
A NOTE ABOUT HUMIDITY 

 

 

It is best to keep the humidity level at about 30-50 percent of relative humidity.  

 

The comfort level of humidity will vary from room to room and with changing room 
conditions.   

 

In cold weather, windows and even some walls may fog or develop frost from 
excessive indoor humidity. If this occurs, reduce the mist intensity setting to avoid 
damage from condensed water dripping on windowsills.  

 

Too much humidity in the room may allow moisture to accumulate on surfaces where 
bacteria and fungi can grow. Moisture that gathers may also damage furniture and 
walls, especially wallpaper.  

 

To eliminate excessive humidity, especially in small rooms, leave the room door open 
and adjust the mist intensity control setting.  

 

 

 

 

Содержание EE-864

Страница 1: ...2 1 GALLON 7 56 LITER ULTRASONIC HUMIDIFIER MODEL EE 864 PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS APPLIANCE ...

Страница 2: ...ety Instructions P 2 General Safety Instructions P 3 List of Main Parts P 4 Tech Specifications Contents of Packaging P 5 Operation and Use P 5 7 Maintenance P 8 9 Trouble Shooting Service Center Information P 10 Warranty Information P 11 Warranty Card P 12 ...

Страница 3: ...es 6 Use only a 110 120VAC outlet ALWAYS plug and unplug unit with dry hands 7 Never operate the unit with a damaged cord or plug 8 Always place the unit on a smooth lint free non metallic waterproof level surface and away from direct sunlight Keep the cord away from heated surfaces and areas where it could be walked on or tripped over Unplug the unit when not in use and whenever you clean or move...

Страница 4: ...d must be arranged so that it will not drape over the countertop or tabletop where it can be pulled on by children or tripped over accidentally ELECTRIC POWER If electric circuit is overloaded with other appliances your appliances may not operate properly The appliances should be operated on a separate electrical circuit from other operating appliances POLARIZED PLUG This appliance has a polarized...

Страница 5: ...Power Light Fig 1 Fig 2 Top of Water Tank 6 Vapor Outlet Channel 7 Water Tank Handle Fig 2 Fig 3 Water Basin 8 Nebulizer 9 Vaporization Chamber 10 Fan Vent 11 Valve Opener 12 Water Level Sensor Fig 3 Fig 4 Bottom of Water Tank 13 Water Tank Valve 14 Water Tank Cap 15 Vapor Outlet Channel Fig 4 Fig 5 Water Tank Lid 16 Water Tank Lid 17 Vapor Output Slot Fig 5 ...

Страница 6: ...rface for best performance This is to help disperse the mist in the air and prevent it from being knocked or tipped over CHECK WATER LEVEL SENSOR Make sure that the water level sensor is secured properly Refer to cleaning and maintaining water level sensor on page 9 for instructions on how to assemble water level sensor CHECK FAN VENT This fan vent is located on the bottom of the humidifier The pu...

Страница 7: ...led water DO NOT use hot water Use cool tap water DO NOT add any medication to other additives to the water DO NOT pour water into Vapor Outlet Channel part 6 Fig 2 on page 4 Fig 7 4 Replace the water tank cap aligning the threads on the tank with the threads on the cap and turn it clockwise See Fig 8 Fig 8 5 Turn the tank over holding one hand by the top handle and another hand under tank Place f...

Страница 8: ...AN ELEVATED NON METALLIC LINT FREE WATERPROOF LEVEL SURFACE FOR BEST PERFORMANCE Adjust the vapor control so that the vapor rises up and gets absorbed by the room air Do not turn on too high output as the vapor cannot be absorbed by the air and accumulates on the surface around the humidifier If the humidifier is placed near a fan or air conditioning outlet the vapor may be forced down by the fore...

Страница 9: ...ith a soft cloth dampened in the bleach or white vinegar and water solution Rinse the water basin with cool water to remove any smell DO NOT IMMERSE WATER BASIN IN WATER 3 Wipe all exteriors surfaces of the base with a soft dry cloth Do not immerse the base in water or use water to clean the base An electric shock may result or the humidifier may be damaged GENERAL MAINTENANCE AND CLEANING Before ...

Страница 10: ... on the pin by pulling it up see Fig 12 Remove the water float and cap and clean by wiping the parts with a soft damp cloth Replace the parts by first putting the water float onto the pin and then pressing the plastic cap on the end of the pin to secure the float see Fig 13 Do not use excessive force Fig 11 Fig 12 Fig 13 STORING YOUR HUMIDIFIER Allow the appliance to dry completely before storing ...

Страница 11: ... there is water in the tank Check for possible lime deposits on the water level float or the nebulizer Make sure that nothing blocks the vapor output slot Check that the air vent on bottom of humidifier is not blocked Empty the humidifier and rinse the water basin with cool tap water and allow to dry for 15 to 30 min White dust appears and settles outside the humidifier Area tap water may have too...

Страница 12: ...ions provided with the product This warranty does not apply to normal wear and tear as well as commercial use The warranty is non transferable and applies only to the original purchase and does not extend to subsequent owners of the product Liability under this warranty is limited to repair or replacement In no event shall liability exceed the purchase price paid by the purchaser of the product Un...

Страница 13: ...ut the warranty card and include it with a copy of the dated sales receipt In return you will receive your repaired item or a new product at the service center s discretion This Ultrasonic Humidifier was tested and meets our stringent quality standards This product is warranted to be free from manufacturing defects in original materials including original parts and workmanship for 1 year with proo...

Страница 14: ...13 ...

Отзывы: