Please Read This Before Installing Or Operating Pump. 

This information is provided for 

SAFETY

 and to 

PREVENT 

EQUIPMENT PROBLEMS.

 To help recognize this information, 

observe the following symbols:

IMPORTANT!

 Warns about hazards that can result 

in personal injury orIndicates factors concerned with 

assembly, installation, operation, or maintenance which 

could result in damage to the machine or equipment if 

ignored.

CAUTION!

 Warns about hazards that 

can or will cause minor

 

personal injury or property damage if ignored. Used with symbols 

below.

WARNING!

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 

with symbols below. 

Only  qualified  personnel  should  install,  operate  and  repair 

pump. Any  wiring  of  pumps  should  be  performed  by  a  qualified 

electrician.

WARNING !

 To reduce risk of electrical shock, pumps 

and control panels must be properly grounded in 

accordance with the National Electric Code (NEC) or 

the Canadian Electrical Code (CEC) and all applicable 

state, province, local codes and ordinances. Improper 

grounding voids warranty.

WARNING!

 To reduce risk of electrical shock, always 

disconnect the pump from the power source before 

handling or servicing. Lock out power and tag. 

WARNING!

 Operation against a closed 

discharge valve will cause premature bearing 

and seal failure on any pump, and on end 

suction and self priming pump the heat build 

may cause the generation of steam with resulting dangerous 

pressures. It is recommended that a high case temperature 

switch or pressure relief valve be installed on the pump body.

CAUTION !

 Never operate a pump with a plug-in  type 

power cord without a ground fault  circuit interrupter.

 

CAUTION !

 Pumps build up heat and pressure 

during operation-allow time for pumps to cool 

before handling or servicing.

 

WARNING !

 Do not pump hazardous materials 

(flammable, caustic, etc.) unless the pump is specifically 

designed and designated to handle them.

 

CAUTION !

 

Do not

 block or restrict discharge hose, as 

discharge hose may whip under pressure.

 

WARNING !

 Do not wear loose clothing that may  

become entangled in moving parts.

  

WARNING !

 Keep clear of suction and discharge 

openings. 

DO NOT 

insert fingers in pump with power 

connected.  

Always wear eye protection when working on pumps. 

Make sure lifting handles are securely fastened each  

time before lifting. 

DO NOT

 operate pump without safety 

devices in place. Always replace safety devices that  

have been removed during service or repair. Secure the 

pump in its operating position so it can not tip over, fall  

or slide.

 

DO NOT

 exceed manufacturers recommendation for 

maximum performance, as this could cause the motor  

to overheat.

 

DO NOT

 remove cord and strain relief. 

DO NOT

 connect 

conduit to pump.

 

WARNING !

 Cable should be protected at all times to  

avoid punctures, cut, bruises and abrasions. Inspect 

frequently. Never handle connected power cords with  

wet hands.

 

WARNING !

 To reduce risk of electrical shock, all  wiring 

and junction connections should be made per  the NEC 

or CEC and applicable state or province and  local 

codes. Requirements may vary depending on  usage 

and location.

 

WARNING!

 Submersible Pumps are not approved for  

use in swimming pools, recreational water installations 

decorative fountains or any installation where human 

contact with the pumped fluid is common.

  

WARNING!

 Products returned must be cleaned, 

sanitized, or decontaminated as necessary prior to 

shipment, to insure that employees will not be exposed 

to health hazards in handling said material. All Applicable 

Laws And Regulations Shall Apply.

 

Bronze/brass and bronze/brass fitted pumps may 

contain lead levels higher than considered safe for 

potable water systems. Lead is known to cause cancer 

and birth defects or other reproductive harm. Various 

government agencies have determined that leaded 

copper alloys should not be used in  potable water 

applications. For non-leaded copper  alloy materials of 

construction, please contact factory.

 

Crane Pumps & Systems, Inc. is not responsible for 

losses, injury, or death resulting from a failure to observe 

these safety precautions, misuse or abuse of pumps or 

equipment.

SAFETY FIRST!

Hazardous fluids can 

cause fire or explo

-

sions, burnes or death 

could result.

Extremely hot - Severe 

burnes can occur on contact.

Biohazard can cause 

serious personal injury.

Hazardous fluids can Hazard

-

ous pressure, eruptions or ex

-

plosions could cause personal 

injury or property damage.

Rotating machinery

Amputation or severe 

laceration can result.

Hazardous voltage can 

shock, burn or cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.

® Barnes is a registered trademark of Crane Pumps & Systems, Inc.

 

10/2004, 

5/06, 

9/06 

         Alteration 

Rights 

Reserved

Содержание BARNES EP72X

Страница 1: ...nc constant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 119335 Rev G Series EP72X 3 4 HP 3450 RPM 60 Hz ...

Страница 2: ...ps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT...

Страница 3: ...r sealing and strain relief UPPER BEARING Design Single Row Ball Oil Lubricated Load Radial LOWER BEARING Design Single Row Ball Oil Lubricated Load Radial Thrust MOTOR Design Oil Filled Insulation Class B SINGLE PHASE Permanent Split Capacitor PSC Includes Thermal Overload Protection in motor ELECTRICAL 240 Volt 1 Phase 60 Hz 4 3FLA NEMA Start Code A WINDING RESISTANCE Main 7 5 Ω Start 16 5 Ω LEV...

Страница 4: ...arnes representative or Crane Pumps Systems Inc Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location These pumping units are self contained and are recom mended for use in a sump or basin This pump is designed to pump rain water or light effluent nonexplosive and noncor rosive liquids and shall NO...

Страница 5: ...the pump off if the windings become too hot or the load current passing through them becomes too high It will then automatically reset and start the pump up after the motor cools to a safe temperature In the event of an overload the source of this condition should be determined and rectified immediately DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS SECTION D SERVICE AND REPAIR W...

Страница 6: ...sed for ordering and obtaining informa tion E 2 Model Number This designation consists of numbers and letters which represents the horsepower motor phase and voltage and pump design This number is used for ordering and obtain ing information E 3 Date Code The Date Code consists of two numbers which are punched holes in the nameplate This specifies the month and year which indicates the date the un...

Страница 7: ... cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits flu...

Страница 8: ...A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty If ...