background image

3

DISCHARGE .......................

1½” NPT, Female, Vertical

LIQUID TEMPERATURE ....

104°F (40°C) Continuous

MOTOR HOUSING .............

Cast Iron

BODY & STRAINER ...........

Thermoplastic

IMPELLER:

 

Design

 ............

10 vane, vortex, with pump out vanes

 

on back side. Balanced, ISO G6.3

 

Material

 ...........

Cast Iron

SHAFT .................................

Stainless Steel

O-RINGS .............................

Buna-N

HARDWARE .......................

300 Series Stainless Steel

PAINT ..................................

Air dry enamel

SEAL

 

Design

 .............

Single Mechanical, Type 21

 

Material

 ...........

Carbon/Ceramic/Buna-N

 

Hardware - 300 series stainless steel

CORD ENTRY .....................

20 Ft. (6m) Quick disconnect cord  

  

with plug, pressure gromment for

 

sealing and strain relief.

UPPER BEARING:

 

Design

 .............

Single Row, Ball, Oil Lubricated

 

Load

 ................

Radial

LOWER BEARING:

 

Design

 .............

Single Row, Ball, Oil Lubricated

 

Load

 ................

Radial & Thrust

MOTOR:

 

Design

 .............

Oil Filled

 

Insulation

 ........

Class B

SINGLE PHASE ..................

Permanent Split Capacitor (PSC)

 

Includes Thermal Overload 

 

Protection in motor

ELECTRICAL ......................

240 Volt, 1 Phase,

 

60 Hz, 4.3FLA, NEMA Start Code A

WINDING RESISTANCE:

 

Main

 ................

7.5 Ω

 

Start

 ................

16.5 Ω

LEVEL CONTROLS:

 EP72X ............. None

 EP72XA .......... Wide Angle, Mechanical, 20 Ft. (6m)

 

Cord w/Piggy-back plug

 EP72XV .......... Vertical Float, PVC, Snap Action,

 

20 Ft. (6m) cord

MINIMUM SUMP DIA:

 EP72AX .......... 18” (457mm)

 

EP72X &

 EP72VFX ........ 12” (305mm)

 

PUMP SPECIFICATIONS:

inches

(mm)

Model: EP72X

Model: EP72VFX

Vertical Float

Model: EP72AX

Wide Angle Float

FIGURE 1

Содержание BARNES EP72X

Страница 1: ...nc constant product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 119335 Rev G Series EP72X 3 4 HP 3450 RPM 60 Hz ...

Страница 2: ...ps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat DO NOT...

Страница 3: ...r sealing and strain relief UPPER BEARING Design Single Row Ball Oil Lubricated Load Radial LOWER BEARING Design Single Row Ball Oil Lubricated Load Radial Thrust MOTOR Design Oil Filled Insulation Class B SINGLE PHASE Permanent Split Capacitor PSC Includes Thermal Overload Protection in motor ELECTRICAL 240 Volt 1 Phase 60 Hz 4 3FLA NEMA Start Code A WINDING RESISTANCE Main 7 5 Ω Start 16 5 Ω LEV...

Страница 4: ...arnes representative or Crane Pumps Systems Inc Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada Inc Bramton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location These pumping units are self contained and are recom mended for use in a sump or basin This pump is designed to pump rain water or light effluent nonexplosive and noncor rosive liquids and shall NO...

Страница 5: ...the pump off if the windings become too hot or the load current passing through them becomes too high It will then automatically reset and start the pump up after the motor cools to a safe temperature In the event of an overload the source of this condition should be determined and rectified immediately DO NOT LET THE PUMP CYCLE OR RUN IF AN OVERLOAD CONDITION OCCURS SECTION D SERVICE AND REPAIR W...

Страница 6: ...sed for ordering and obtaining informa tion E 2 Model Number This designation consists of numbers and letters which represents the horsepower motor phase and voltage and pump design This number is used for ordering and obtain ing information E 3 Date Code The Date Code consists of two numbers which are punched holes in the nameplate This specifies the month and year which indicates the date the un...

Страница 7: ... cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eliminate leakage 12 Check pump temperature limits flu...

Страница 8: ...A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty If ...

Отзывы: