8
CHART ‘C’
MODEL
NO
HP
V
O
LT
PH
Hz
RPM (Nom)
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
T
OR
AMPS
CORD SIZE
WINDING
RESIST
ANCE
8SHDA
8SHDA75044
75
460
3
60
1750
G
108.4
1.15
120.7
578.0
2/4 - 18/4
0.07
8SHDA75054
75
575
3
60
1750
G
86.7
1.15
96.6
462.4
2/4 - 18/4
0.095
8SHDA100044
100
460
3
60
1750
E
136.6
1.15
155.3
578.0
2/4 - 18/4
0.07
8SHDA100054
100
575
3
60
1750
E
109.2
1.15
124.2
462.4
2/4 - 18/4
0.095
8SHDA125044
125
460
3
60
1750
F
169.4
1.15
191.5
800.0
1/0/4 - 18/4
0.049
8SHDA125054
125
575
3
60
1750
F
135.6
1.15
153.2
640.0
2/4 - 18/4
0.065
8SHDA150044
150
460
3
60
1750
D
187.0
1.0
187.0
800.0
1/0/4 - 18/4
0.049
8SHDA150054
150
575
3
60
1750
D
159.5
1.0
159.5
640.0
1/0/4 - 18/4
0.065
8SHTM
8SHTM75044
75.0
460
3
60
1750
G
108.4
1.15
120.7
578
2/4-18/4
.070
8SHTM75054
75.0
575
3
60
1750
G
86.7
1.15
96.6
462.4
2/4-18/4
.095
8SHTM100044
100.0
460
3
60
1750
E
136.6
1.15
155.3
578
2/4-18/4
.070
8SHTM100054
100.0
575
3
60
1750
E
109.2
1.15
124.2
462.4
2/4-18/4
.095
8SHTM125044
125.0
460
3
60
1750
F
169.4
1.15
191.5
800.0
1/0/4-18/4
.049
8SHTM125054
125.0
575
3
60
1750
F
135.6
1.15
153.2
640.0
2/4-18/4
.065
8SHTM150044
150.0
460
3
60
1750
D
187.0
1.0
187.0
800.0
1/0/4-18/4
.049
8SHTM150054
150.0
575
3
60
1750
D
159.5
1.0
159.5
640.0
1/0/4-18/4
.065
8SHTM50046
50.0
460
3
60
1150
H
76.4
1.15
84.0
400.0
6/4-18/4
.130
8SHTM50056
50.0
575
3
60
1150
H
61.2
1.15
67.2
320.0
6/4-18/4
.189
8SHTM60046
60.0
460
3
60
1150
F
86.7
1.15
96.8
400.0
2/4-18/4
.130
8SHTM60056
60.0
575
3
60
1150
F
69.4
1.15
77.4
320.0
6/4-18/4
.189
8SHTM75046
75.0
460
3
60
1150
H
109.3
1.15
119.5
612.0
2/4-18/4
.077
8SHTM75056
75.0
575
3
60
1150
H
87.4
1.15
95.6
489.6
2/4-18/4
.1
13
8SHTM100046
100.0
460
3
60
1150
E
135.0
1.0
135.0
612.0
2/4-18/4
.077
8SHTM100056
100.0
575
3
60
1150
E
108.0
1.0
108.0
489.6
2/4-18/4
.1
13
8SHTM40048
40.0
460
3
60
870
F
62.2
1.15
69.4
275.0
6/4-18/4
.166
8SHTM40058
40.0
575
3
60
870
F
49.8
1.15
55.5
220.0
8/4-18/4
.226
Moisture and
Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor
.
Cord sold separately
.
Cord Suffix: XF - 50 Feet, XJ - 75 Feet, or XL
- 100 Feet
Содержание 4SHD
Страница 18: ...18 FIGURE 9 SH Pump Series CROSS SECTIONS FIGURE 10 SH Vortex SH Enclosed ...
Страница 19: ...19 SH Enclosed Pump Series EXPLODED VIEWS FIGURE 11 ...
Страница 34: ...Notes ...