CHART ‘H’
MODEL NO
.
SIZE
IMP
. DIA.
INCHES
(MM)
HP
V
O
LT
PH
HZ
RPM
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
TO
R
AMPS
DRIVER FRAME
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
7365-659-31-30N
6VT
**
20
208
3
60
870
J
69.0
1.2
76.0
400.0
4
138318
6/4 - 18/4
1.47 ± .03
.121
230
75.1
1.2
79.0
4
138318
6/4 - 18/4
7365-659-91-30N
6VT
**
20
460
3
60
870
J
37.6
1.2
41.1
200.0
4
138317
8/4 - 18/4
1.12 ± .02
.483
7365-659-1A-30N
6VT
**
20
575
3
60
870
J
30.1
1.2
32.9
160.0
4
138317
8/4 - 18/4
1.12 ± .02
.77
7365-659-32-30N
6VT
**
25
208
3
60
870
H
82.3
1.2
98.8
400.0
4
138319
2/4 - 18/4
1.47 ± .03
.121
230
84.0
1.2
94.5
4
138319
2/4 - 18/4
7365-659-92-30N
6VT
**
25
460
3
60
870
H
42.0
1.2
47.2
200.0
4
138317
8/4 - 18/4
1.12 ± .02
.483
7365-659-1B-30N
6VT
**
25
575
3
60
870
H
33.6
1.2
37.8
160.0
4
138317
8/4 - 18/4
1.12 ± .02
.77
7365-659-33-30N
6VT
**
30
208
3
60
870
F
98.8
1.2
124.1
400.0
4
138319
2/4 - 18/4
1.47 ± .03
.121
230
94.5
1.2
108.6
4
138319
2/4 - 18/4
7365-659-93-30N
6VT
**
30
460
3
60
870
F
47.2
1.2
54.3
200.0
4
138317
8/4 - 18/4
1.12 ± .02
.483
7365-659-1C-30N
6VT
**
30
575
3
60
870
F
37.8
1.2
43.5
160.0
4
138317
8/4 - 18/4
1.12 ± .02
.77
▲
CORD SOLD SEP
ARA
TEL
Y. CORD SUFFIX: XF - 50 FEET
, XJ - 75 FEET
, OR XL
- 100 FEET
.
IMPOR
TANT !
1.)
MOISTURE
AND
TEMPERA
TURE SENSORS
MUST
BE CONNECTED
TO V
ALIDA
TE
THE CSA
LISTING.
2.)
A SPECIAL
MOISTURE SENSOR RELA
Y IS REQUIRED IN
THE CONTROL
P
ANEL
FOR PROPER OPERA
TION OF
THE MOISTURE SENSORS.CONT
ACT
CP&S FOR INFORMA
TION CONCERNING MOISTURE SENSING RELA
YS FOR
CUST
OMER SUPPLIED CONTROL
P
ANELS.
3.)
THESE PUMPS
ARE CSA
LISTED FOR PUMPING W
ATER
AND W
ASTEW
ATER.
DO NOT USE T
O PUMP
FLAMMABLE LIQUIDS
. NOT
SUIT
ABLE FOR ENVIRONMENTS CONT
AINING GASOLINE OR HEXANE.
4.)
INST
ALLA
TIONS SUCH
AS DECORA
TIVE FOUNT
AINS OR W
ATER FEA
TURES PROVIDED FOR VISUAL
ENJOYMENT
MUST
BE INST
ALLED IN
ACCORDANCE WITH
THE NA
TIONAL
ELECTRIC CODE
ANSI/NFP
A 70
AND/OR
THE
AUTHORITY
HA
VING JURISDICTION.
THIS PUMP
IS NOT
INTENDED FOR USE IN SWIMMING POOLS, RECREA
TIONAL
W
ATER P
ARKS, OR INST
ALLA
TIONS IN WHICH HUMAN CONT
ACT
WITH PUMPED MEDIA
IS
A COMMON OCCURRENCE.
5.)
A
NON-SP
ARKING
BREAKA
W
AY
FITTING MUST
BE USED
TO V
ALIDA
TE
THE EXPLOSION PROOF LISTING.
6.)
WINDING RESIST
ANCE
± 7.5%. WINDING RESIST
ANCE MEASURED IN OHMS @ 25°C (BETWEEN LINES)
AT
MOT
OR LEADS.
7.)
PUMP
RA
TED FOR OPERA
TION
AT
± 10% VOL
TAGE
AT
MOT
OR.
**
SELECT
IMPELLER DIAMETER WHEN ORDERING.