- 52 -
VI - COMMISSIONING
1 - PROTECTION OF THE INSTALLATION
To guarantee the boiler shell,
it is
recommend
ed
that only
the following
heating system
water
conditioning products are used:
- BIONIBAL corrosion inhibitor
- BIONIBAGEL antifreeze and corrosion inhibitor.
1.1 - Bionibal
BIONIBAL
is a non-toxic, biocide, traceable corro-
sion inhibitor specially designed to protect multi-me-
tal heating circuits.
Through its efficient means of acting against all ty-
pes of corrosion and all types of bacteria, BIONI-
BAL:
- Prevents the formation of rust and metallic slud-
ge,
- Prevents the formation of algae and bacteria
sludge,
- Also suitable for under-floor heating systems,
- Prevents off-gases,
- Contains an internal marker so that doses can be
easily controlled.
BIONIBAL DOSAGE:
- Without under-floor heating: 1% (0.5 l of BIONI-
BAL for 50 l of water).
- With under-floor heating: 2% (1 l of BIONIBAL for
50 l of water).
1.2 - Bionibagel
BIONIBAGEL
is the antifreeze version of BIONI-
BAL.
Non-toxic antifreeze, with glycol monopropylene ba-
se, corrosion inhibitor, biocide, traceable.
In addition to the characteristics of BIONIBAL, it pro-
tects the installation from frost for residences that
are not inhabited all the year round or that are in the
coldest regions.
BIONIBAGEL DOSAGE:
The number of litres of BIONIBAGEL to put in the
circuit depends on the volume of your installation
and the extreme temperature of your region.
Important warning
Bionibal or Bionibagel must only be put in a clean installation that has been checked. It is the-
refore imperative to fill the entire system one or more times with clean water as required. In
some cases, the system may need washing by a suitable product:
Example:
- In a new installation: To detect any leaks and eliminate any traces of welding, weld solder
or other residues.
- On an old installation: To eliminate any trace of sludge and other products in the radiators,
under-floor heating system and the boiler.
!
Protection
limit
temperature
Installation capacity (litres)
50
100
150
200
- 5°C
7
15
22
30
- 10°C
12
25
37
50
- 15°C
17
35
50
70
- 20°C
20
40
60
80
- 30°C
22
45
67
90
!
Содержание THI 5-25c
Страница 62: ... 77 NOMENCLATURE THI 5 25 C ...