SETTINGS OF THE INSTALLATION TYPES
The flow temperature of each circuit is defined by
the heating curve for that circuit.
This temperature is corrected by using the boiler
heating potentiometer (setting from 17°C to 23°C).
Correction of the room temperature
using the heating potentiometer acts on
both heating circuits simultaneously.
Only one QAA73 room sensor can be connected to
the LMU. It can control one or two circuits.
The QAA73 room sensor is configured in the
factory on the CC1 radiator circuit.
The sensor defines the flow settings required as well
as the domestic hot water temperature and sends
them to the boiler control on the basis of the outside
temperature, room temperature and various other
parameters.
The heating and domestic hot water potentiometers
are then disabled when the sensor is connected.
3 - ACCESS THE SETTINGS VIA THE QAA 73 ROOM SENSOR
Initial display of the QAA 73 room sen-
sor before the settings are entered:
3.1 - Access the lines 51 to 98
2.1 - Without room sensor
!
2.2 - With room sensor
!
T
H
I-
03-
0
Buttons
Explanation
Line
1
Press one of the 2 line selection buttons.
- This will take you to the programming mode "End-user”. (1. level)
Display :
Note Initial language is French - go to line 47 to select English
2
Press both line selection buttons for at least 3 seconds.
- This will take you to the programming mode "Heating engineer" (2. level)
Display :
3
Press the line selection buttons to select the required line.(rep. b).
. . .
4
Press the plus or minus button to enter the required value (rep. c). The setting will be stored as soon as
you leave the programming mode (by pressing the Info button) or change to another line.
P R OG
TH
I-
49
-3
P R OG
TH
I-
50
-3
a)
Line name
b)
Line number
c)
Setting of the parameter
b)
a)
c)