900-R Installation Manual
4.4 RF Address Setting
The host end module 900-PRIME can work with one or two 900-Rs. Unit 1 and unit
2
MUST
be set to different address from each other. This setting is done by DIP
setting switch SW3.
SW3-S1
SW3-S2
SW3-S3
ADDRESS
OFF
OFF
OFF
#0
ON
OFF
OFF
#1
4.5 Input Setting
Figure 4-4 RF Address Setting
Factory default of these units are Unsupervised. This selection can be changed to Supervised
by setting S7 of SW3 to “ON”.
SW3-S7
Input type
OFF
Unsupervised
ON
Supervised
4.6 Reader Power Setting
Figure 4-5 (Un) Supervised Input Selection
A built in reader interface on 900-R can support 5Vdc (100mA) or 12Vdc (100mA) reader.
Jumper S3 is for reader power selection.
Setting
Description
Function
ON / Closed
5Vdc to Reader
OFF / Open
12Vdc to Reader
Figure 4-6 Reader Power Setting
6