background image

7

E

Finding a Stud

1.

 

To hold the stud sensor, place your thumb on one side of the 
stud sensor, your pointer finger and your palm over the center 
of the stud sensor, and the rest of your fingers on the same 
hand on the other side of the stud sensor (Figure 

C

).

2.

 

Position the stud sensor flat against the wall and parallel 
to a door or window on the same wall, which give you an 
indication of how the studs are positioned behind the wall.

3.

 

Without moving the stud sensor, use your pointer finger to 
press and hold 

 until all the LEDs (except the green Power  

 LED) turn off (1 sec).

4.

 

While still pressing 

, SLOWLY move the stud sensor to the 

left or the right on the wall.

5.

 

As you move the stud sensor, watch the stud sensor LEDs.

• If 

 lights (Figure 

A

 

7

), move the stud sensor to the 

left to find the nearest stud.

• If 

 lights (Figure 

A

 

4

), move the stud sensor to the 

right to find the nearest stud.

6.

 

When the center LED (Figure 

A

 

5

) lights and you hear a 

constant beep, the stud sensor has found the center of a 
stud (Figure 

D

 

1

).

• STOP moving the stud sensor.
• STOP pressing 

 (Figure 

D

 

2

).

7.

 

Through the hole on the stud sensor (Figure 

D

 

3

), use a 

pencil to mark the current position as the center of the stud.

8.

 

To find another stud on the wall, repeat the same steps.

Finding Live AC

1.

 

To hold the stud sensor, place your thumb on one side of the 
stud sensor, your pointer finger and your palm over the center 
of the stud sensor, and the rest of your fingers on the same 
hand on the other side of the stud sensor (Figure 

C

).

2.

 

Gently place the stud sensor flat against the wall and 
parallel to a door or window on the same wall, which give 
you an indication of how the studs are positioned behind the 
wall.

3.

 

Without moving the stud sensor, press and hold 

 until all 

the LEDs (except the green Power   LED) turn off (1 sec).

4.

 

While still pressing 

SLOWLY

 move the stud sensor to the 

left or the right on the wall.

5.

 

As you move the stud sensor, watch the LEDs and listen for 
beeps. The AC LED (Figure 

A

 

3

) will start illuminating and 

the stud sensor will sound a cadenced beep from a typical 
distance of 6”-18” (.15m - .5m) away from the live AC. Since 
AC wires are usually attached to studs, the directional LEDs 
will help you find live AC wires that may be attached to the 
nearest stud.

• If 

 lights (Figure 

A

 

7

), move the stud sensor to the 

left to find the nearest stud.

• If 

 lights (Figure 

A

 

4

), move the stud sensor to the 

right to find the nearest stud.

• If live AC voltage is found within 6”-18” (.15m - .5m) of 

the stud sensor’s current position, the AC LED (Figure 

A

 

3

) will illuminate and you will hear a few short beeps. 

• If live AC voltage is found near the center of a stud, both 

the AC LED and the center red LED (Figure 

A

  

5

) will illuminate and the stud sensor will sound the 

short alternating beeps (AC found) followed by a longer 
constant beep (stud center found), and repeat these beeps 
until you stop pressing 

.

Maintenance

•  When the stud sensor is not in use, clean the exterior parts 

with a damp cloth, wipe the stud sensor with a soft dry cloth to 
make sure it is dry.

•  Although the stud sensor exterior is solvent resistant, NEVER 

use solvents to clean the stud sensor.

•  Store the stud sensor in a clean location at a temperature 

between -67 ˚F (-55 ˚C) and 158 ˚F (70 ˚C).

Содержание CMHT77621

Страница 1: ...CMHT77620 CMHT77621 User Manual E PT ES F Please read these instructions before operating the product www CRAFTSMAN com AC ...

Страница 2: ...A 1 3 2 4 5 7 6 Figures 2 AC AC AC AC ...

Страница 3: ...B 3 _ _ ...

Страница 4: ...C D AC Figures 4 AC ...

Страница 5: ...erate injury NOTICE Indicates a practice not related to personal injury which if not avoided may result in property damage If you have any questions or comments about this or any CRAFTSMAN tool go to http www CRAFTSMAN com WARNING Read and understand all instructions Failure to follow the warnings and instructions in this manual may result in serious personal injury SAVE THESE INSTRUCTIONS WARNING...

Страница 6: ...stalling AAA Batteries Load two new AAA batteries in the CMHT77620 CMHT77621 stud sensor 1 On the bottom of the laser lift up the latch Figure B 1 to unlock the battery compartment cover 2 Move the cover upward Figure B 2 and remove it once it separates from the stud sensor 3 Insert two new high quality AAA batteries making sure to position the and ends of each battery as noted inside the battery ...

Страница 7: ...ly place the stud sensor flat against the wall and parallel to a door or window on the same wall which give you an indication of how the studs are positioned behind the wall 3 Without moving the stud sensor press and hold until all the LEDs except the green Power LED turn off 1 sec 4 While still pressing SLOWLY move the stud sensor to the left or the right on the wall 5 As you move the stud sensor...

Страница 8: ... stud sensor SLOWLY against the wall Make sure the wall is not too thick CMHT77620 can be used on walls 75 19mm thick and CMHT77621 can be used on walls 1 5 38mm thick Make sure the wall has a smooth surface Make sure the temperature is within the specified Operating Range and Relative Humidity Service and Repairs Note Disassembling the tool will void all warranties on the product To assure produc...

Страница 9: ... 3 4 12 7mm 19mm thick drywall 1 4 6 4mm under 1 2 1 5 12 7mm 38mm thick drywall Accuracy Center of Metal stud 1 4 6 4mm under 1 2 3 4 12 7mm 19mm thick drywall 1 4 6 4mm under 1 2 1 5 12 7mm 38mm thick drywall Power Source 2 AAA 1 5V size batteries 3V DC Battery Life 20 hrs of continual use at 2 4V 0 3V Power LED will flash to indicate low battery Automatic Calibration Yes Automatic Shutoff when ...

Отзывы: