CAUTION:

Use personal protective equipment. Always wear eye 

protection. Depending on the work conditions, wearing 

protective equipment such as a dust mask, non-skid 

safety shoes, hard hat, and hearing protection will 

reduce the risk of personal injury.

IMPORTANT SAFETY NOTICE

Ensure proper detection of live wires. Always hold the Stud Sensor 
CMHT77620/CMHT77621 in the handle area only. Grasp between 
fingers and thumb while making contact with your palm (Figure 

C

).

NOTE:

 Static electrical charges that can develop on drywall and 

other surfaces will spread the voltage detection area many inches 
on each side of the actual electrical wire. To aid in locating the 
wire position, scan holding the unit ½” (13mm) away from the 
wall surface or place your other hand on the surface approximately 
12” (305mm) from the sensor.

Battery Safety

WARNING: 

Batteries can explode, or leak, and can cause injury 

or fire. 

To reduce this risk:

•  Carefully follow all instructions and warnings on the battery 

label and package.

•   Always insert batteries correctly with regard to polarity (+ and 

–), as marked on the battery and the equipment.

•  Do not short battery terminals.
•  Do not charge disposable batteries.
•  Do not mix old and new batteries. Replace all batteries at the 

same time with new batteries of the same brand and type.

•  Remove dead batteries immediately and dispose of per local 

codes.

•  Do not dispose of batteries in fire.
•  Keep batteries out of reach of children.

Installing AAA Batteries

Load two new AAA batteries in the CMHT77620/CMHT77621 stud 
sensor.

1.

 

On the bottom of the laser, lift up the latch (Figure 

B

 

1

to unlock the battery compartment cover.

2.

 

Move the cover upward (Figure 

B

 

2

) and remove it once it 

separates from the stud sensor.

3.

 

Insert two new, high-quality AAA batteries, making sure to 
position the - and + ends of each battery as noted inside the 
battery compartment (Figure 

B

 

3

).

4.

 

Place the cover back on the stud sensor.

• Insert the two pins at the top of the cover into the holes in 

the stud sensor (Figure 

B

 

4

).

• Slowly lower the cover and press down until the latch locks 

securely on the stud sensor (Figure 

B

 

5

).

5.

 

Press 

 to test the stud sensor.

• All the LEDs except the green Power   LED should 

illuminate for a second and then turn off.

• Whenever you press 

, the green Power   LED should 

illuminate to indicate that the batteries are good. If this 
LED blinks or does not illuminate, change the batteries.

Using the Stud Sensor

The stud sensor will help you find wood or metal studs, and AC 
voltage behind drywall.

•  CMHT77620 will work on up to 3/4” (19mm) thick drywall.
•  CMHT77621 will work on up to 1.5” (38mm) thick drywall.
•  CMHT77620 and CMHT77621 will detect AC voltage through up 

to 2” (50.8mm) thick drywall.

•  When AC voltage is found, the stud sensor will sound a few 

short (alternating) beeps and light the AC LED (Figure 

A

 

3

).

•  When the center of a stud is found, the stud sensor will sound 

one longer (constant) beep and light the center LED (Figure 

A

 

5

).

•  When live AC and the center of a stud are both found, the stud 

sensor will sound both the long beep and the short beeps, and 
light the center and AC LEDs.

Содержание CMHT77621

Страница 1: ...CMHT77620 CMHT77621 User Manual E PT ES F Please read these instructions before operating the product www CRAFTSMAN com AC ...

Страница 2: ...A 1 3 2 4 5 7 6 Figures 2 AC AC AC AC ...

Страница 3: ...B 3 _ _ ...

Страница 4: ...C D AC Figures 4 AC ...

Страница 5: ...erate injury NOTICE Indicates a practice not related to personal injury which if not avoided may result in property damage If you have any questions or comments about this or any CRAFTSMAN tool go to http www CRAFTSMAN com WARNING Read and understand all instructions Failure to follow the warnings and instructions in this manual may result in serious personal injury SAVE THESE INSTRUCTIONS WARNING...

Страница 6: ...stalling AAA Batteries Load two new AAA batteries in the CMHT77620 CMHT77621 stud sensor 1 On the bottom of the laser lift up the latch Figure B 1 to unlock the battery compartment cover 2 Move the cover upward Figure B 2 and remove it once it separates from the stud sensor 3 Insert two new high quality AAA batteries making sure to position the and ends of each battery as noted inside the battery ...

Страница 7: ...ly place the stud sensor flat against the wall and parallel to a door or window on the same wall which give you an indication of how the studs are positioned behind the wall 3 Without moving the stud sensor press and hold until all the LEDs except the green Power LED turn off 1 sec 4 While still pressing SLOWLY move the stud sensor to the left or the right on the wall 5 As you move the stud sensor...

Страница 8: ... stud sensor SLOWLY against the wall Make sure the wall is not too thick CMHT77620 can be used on walls 75 19mm thick and CMHT77621 can be used on walls 1 5 38mm thick Make sure the wall has a smooth surface Make sure the temperature is within the specified Operating Range and Relative Humidity Service and Repairs Note Disassembling the tool will void all warranties on the product To assure produc...

Страница 9: ... 3 4 12 7mm 19mm thick drywall 1 4 6 4mm under 1 2 1 5 12 7mm 38mm thick drywall Accuracy Center of Metal stud 1 4 6 4mm under 1 2 3 4 12 7mm 19mm thick drywall 1 4 6 4mm under 1 2 1 5 12 7mm 38mm thick drywall Power Source 2 AAA 1 5V size batteries 3V DC Battery Life 20 hrs of continual use at 2 4V 0 3V Power LED will flash to indicate low battery Automatic Calibration Yes Automatic Shutoff when ...

Отзывы: