19 - ENG
A14841
6. Remove the outlet pressure
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
7. Remove
the
regulator.
8. Apply pipe sealant tape to the
nipple.
9. Assemble the regulator and
orient as shown.
NOTE: Arrow indicates flow of
air. Make sure it is pointing in the
direction of air flow.
10. Reapply pipe sealant to outlet
pressure gauge, tank pressure
gauge, and quick connect.
11. Reassemble outlet pressure
gauge,tank pressure gauge, and
quick connect. Orient outlet
pressure gauge and tank
pressure gauge to read correctly
Tighten quick connect with
wrench.
12. Rotate pressure switch assemble
into correct position.
13. Replace console cover and
regulator ring.
To Replace Regulator
1. Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2. Unplug
unit.
3. Remove the regulator ring and
remove the console cover,
gauge and quick connect. Orient
outlet pressure gauge to read
correctly. Tighten quick connect
with wrench.
4. Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
5. Using an adjustable wrench,
rotate the pressure switch
assembly as shown.
Regulator
Quick
Connect
Tank
Pressure
Gauge
Outlet
Pressure
Gauge
Regulator
Ring
Cover
Regulator
12. Replace the outlet tube and
tighten nuts.
13. Replace shrouds and console.
14. Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
Arrow