background image

14- ENG 

A14841

Cooling System (not shown):  This 
compressor contains an advanced 
design cooling system. At the 
heart of this cooling system is an 
engineered fan. It is perfectly normal 
for this fan to blow air through the 
vent holes in large amounts. You 
know that the cooling system is 
working when air is being expelled.

Air Compressor Pump (not 
shown):
  Compresses air into the 
air tank.  Working air is not available 
until the compressor has raised 
the air tank pressure above that 
required at the air outlet.

Check 
Valve:
  
When the air 
compressor 
is operating, 
the check 
valve is 
"open", 
allowing 
compressed 
air to enter the air tank.  When the 
air compressor reaches "cut-out" 
pressure, the check valve "closes", 
allowing air pressure to remain inside 
the air tank.

Air Intake Filter (not shown):  This 
filter is designed to clean air coming 
into the pump. This filter must 
always be clean and ventilation 
openings free from obstructions. See 
"Maintenance".

Check Valve

Before Starting  

Break-in Procedure

Serious damage 
may result if the 

following break-in instructions are 
not closely followed.

This procedure is required before the 
air compressor is put into service and 
when the check valve or a complete 
compressor pump has been replaced.

1.  Make sure the "On/Auto/Off" 

lever is in the "OFF" position.

NOTE: If quick connect is installed, 
pull coupler back until it clicks to 
prevent air from escaping through the 
quick connect.

How to Use Your Unit

How to Stop:

1.  Set the "On/Auto/Off" lever to 

"OFF".

Safety 

Valve

Outlet 

Pressure 

Gauge

Tank

Pressure 

Gauge

"On/Auto/

Off" Switch

Pressure 

Switch

Regulator

Quick 

Connect

Pressure 
Release 
Valve:
  The 
pressure 
release 
valve, 
located on 
the side of 
the pressure switch, is designed to 
automatically release compressed air 
from the compressor head and the 
outlet tube when the air compressor 
reaches "cut-out" pressure or is shut 
off. The pressure release valve allows 
the motor to restart freely. When the 
motor stops running, air will be heard 
escaping from this valve for a few 
seconds.  No air should be heard 
leaking when the motor is running, or 
continuous leaking after unit reaches 
"cut-out"  pressure.

Pressure 

Release

Valve

Содержание 919.724591

Страница 1: ...SSOR Safety Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts Model No 919 724591 CAUTION ReadtheSafetyGuidelinesand All Instructions Carefully Before Operating Sold by Sears Canada Inc Toronto Ont M5B 2B8 A14841 Rev 0 10 14 05 ...

Страница 2: ...aterial or workmanship within one year from the date of purchase Sears will at its option repair or replace it free of charge Contact your nearest Sears Service Center 1 800 4 MY HOME to arrange for product repair or return the CRAFTSMAN product to the place of purchase for replacement If this Air Compressor is used for commercial or rental purposes this warranty applies for only ninety days from ...

Страница 3: ...n relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS To help you recognize this information we use the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or...

Страница 4: ...property damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required Store flammable materials in a secure location away from comp...

Страница 5: ...ondensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure Never drill into weld or make any modifications to the tank or its attachments Excessive vibration can weaken the air tank and cause rupture or explosion The tank is desi...

Страница 6: ...rect voltage and adequate fuse protection Sprayed materials such as paint paint solvents paint remover insecticides weed killers may contain harmful vapors and poisons Work in an area with good cross ventilation Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying Use a NIOSH MSHA approved respirator designed for use with your speci...

Страница 7: ...othing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate compressor in a stable secure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations HAZARD ...

Страница 8: ... parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Transporting Compressor Oil can leak or spill and could result in fire or breathing hazard serious injury or death can result oil leaks will damage carpet paint or other surfaces in vehicles or trailers ...

Страница 9: ...e drops to a certain low level the motor will restart automatically The low pressure at which the motor automatically restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than it...

Страница 10: ...or will have a tendency to tip 1 Attach wheels with shoulder bolts and nuts as shown NOTE Place the bolts in the bottom hole of the wheel bracket on units 20 29 gallons and in the top hole on units 30 gallons and up 2 Tighten securely NOTE The unit will sit level if the wheels are properly installed The wheels and handle do not provide adequate clearance stability or support for pulling the unit u...

Страница 11: ...ng wire with an appropriate grounding plug see following illustrations The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The outlet being used must be installed and grounded in accordance with all local cod...

Страница 12: ...e and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is not used to supply any other electrical needs lights appliances etc 3 Extension cords comply with specifications 4 Circuit is equipped with a 15 amp circuit breaker or 15 amp time delay fuse NOTE If...

Страница 13: ...e air compressor at its cut out pressure setting the safety valve will protect against high pressure by popping out at its factory set pressure slightly higher than the pressure switch cut out setting Outlet Pressure Gauge The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator This pressure is controlled by the regulator and is always less than or equal ...

Страница 14: ...k in Procedure Serious damage may result if the following break in instructions are not closely followed This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE If quick connect is installed pull coupler back until it clicks to prevent air from esc...

Страница 15: ...to cut out pressure and the motor will stop The compressor is now ready for use 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never ...

Страница 16: ...matically when power is on When performing maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any maintenance or repair disconnect power source from the compressor and bleed off all air pressure To Check Safety Valve If the safety valve does not work properly over pressurization may occur causing air tank rupture or an exp...

Страница 17: ...ORTANT Do not operate the compressor with the air filter removed Motor The motor has an automatic reset thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor will automatically restart after the motor cools If the overload protector shuts the motor off frequently check ...

Страница 18: ...uts Unit cycles automatically when power is on When doing Maintenance you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any Maintenance or repair unplug the compressor and bleed off all air pressure ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN To Replace or Clean Check Valve 1 Relea...

Страница 19: ...ure switch assemble into correct position 13 Replace console cover and regulator ring To Replace Regulator 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the regulator ring and remove the console cover gauge and quick connect Orient outlet pressure gauge to read correctly Tighten quick connect with wrench 4 Using an adjustable wrench lo...

Страница 20: ...re is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve can then be remov...

Страница 21: ...fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pressure switch release valve Contact a Trained Service Technician Air leaks in air tank or at air tank welds Defective air tank Air tank must be replaced Do not repair the leak Do not drill into weld or otherwise modify air...

Страница 22: ...ressor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air intake filter Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Check and replace...

Страница 23: ...tch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wrong length or gauge Check for proper gauge wire and cord length Loose electrical connections Check wiring connection inside pressure switch and terminal box area Have checked by a Trained Service Tech...

Страница 24: ... la première année après la date d achat Sears à sa seule discrétion réparera ou remplacera le produit sans frais Contactez le Centre de service après vente Sears le plus près au 1 800 4 MY HOMEMD pour faire réparer le produit ou retournez le produit CRAFTSMAN au magasin où vous en avez fait l achat pour obtenir un rem placement Cette garantie ne s applique que pour une période de quatre vingt dix...

Страница 25: ...écution de ce genre de travaux Afin de réduire l exposition à ces produits chimiques travaillez dans un endroit bien aéré et utilisez de l équipement de sécurité approuvé portez toujours un masque facial ou respirateur homologué MSHA NIOSH bien ajusté lorsque vous utilisez de tels outils Lorsque vous utilisez un outil pneumatique il faut toujours suivre les mesures de sécurité de base afin de rédu...

Страница 26: ...ituer le compresseur à une distance d au moins 20 pieds 6 m de la zone de vaporisation Il peut s avérer nécessaire d utiliser un boyau supplémentaire Entreposer les matières inflammables dans un endroit sécuritaire loin du compresseur Ne jamais placer des objets contre ou sur le compresseur Utiliser le compresseur dans un endroit ouvert à au moins 12 pouces 30 cm de tout mur ou obstruction qui réd...

Страница 27: ...ce qui risque de causer des dommages à la propriété ou des blessures Porter toujours des lunettes de protection homologuées ANSI Z87 1 avec des écrans latéraux lors de l utilisation du compresseur Ne jamais diriger la buse ou le vaporisateur vers soi vers d autres personnes ou vers des animaux Toujours mettre le compresseur hors fonction et purger la pression du boyau d air et du rés ervoir avant ...

Страница 28: ...ctives de mise à la terre L air obtenu directement du compresseur ne devrait jamais être utilisé comme source d air pour les être humains Si l air produit par ce compresseur sera utilisé pour la respiration il faut installer des filtres appropriés ainsi que du matériel de sécurité Les filtres en ligne et le matériel de sécurité utilisés avec le compres seur doivent être dans la mesure de traiter l...

Страница 29: ...ice après vente autorisé Les pièces mobiles telles que la poulie le volant moteur et la courroie peuvent entraîner des blessures graves si elles entrent en contact avec une partie du corps ou des vêtements En tentant de faire fonctionner le compresseur avec des pièces manquantes ou endommagées ou de réparer le compresseur sans les gardes de protection on s expose aux pièces mobiles ce qui peut ent...

Страница 30: ...entez jamais d annuler les caractéristiques de sécurité de ce produit Assurez vous qu un extincteur d incendie est disponible dans l aire de travail N utilisez pas l appareil avec des pièces brisées manquantes ou non autorisées AVERTISSEMENT Risque de dommages à la propriété pendant le transport du compresseur Des fuites ou des déversements d huile peuvent se produire et entraîner des risques d in...

Страница 31: ... pression monte et atteint un niveau élevé réglé à l usine avant que le moteur ne s arrête automatiquement protégeant ainsi le réservoir d air d un taux de pression qui excèderait sa capacité La haute pression à laquelle le moteur s arrête s appelle la pression de rupture Circuit de dérivation Le circuit acheminant l électricité du tableau électrique vers la prise murale ACCESSOIRES Cet appareil p...

Страница 32: ...t plus 2 Serrez bien les pièces REMARQUE L appareil sera à niveau si les roues sont posées de manière appropriée Les roues et la poignée n offrent pas un jeu suffisant ni la stabilité ou le support nécessaires pour tirer l appareil en montant ou en descendant des escaliers L appareil doit être soulevé ou poussé sur une rampe Application de la bande en caoutchouc 1 Nettoyez et séchez la surface inf...

Страница 33: ...re adéquatement mis à la terre Ce compresseur d air portatif est doté d un cordon muni d un fil de mise à la terre et d une fiche appropriée de mise à la terre voir l illustration ci dessous La fiche doit être insérée dans une prise de courant installée et mise à la terre conformément à tous les codes et ordonnances électriques locaux 1 Le cordon fourni avec cet appareil comprend une fiche avec br...

Страница 34: ...ences minimums concernant la tension et le circuit de dérivation Certains modèles de compresseur d air peuvent fonctionner sur un circuit de 15 ampères si les conditions suivantes sont satisfaites 1 la tension d alimentation au circuit de dérivation est de 15 A 2 le circuit n est pas utilisé pour alimenter d autres dispositifs électriques lumières appareils électriques etc 3 les rallonges sont con...

Страница 35: ... position OFF pour couper le courant après chaque utilisation Manostat Le manostat démarre automatiquement le moteur lorsque la pression dans le réservoir d air tombe à une valeur inférieure à la pression d amorçage réglée à l usine Il arrête le moteur lorsque la pression dans le réservoir d air atteint la pression de rupture réglée à l usine Soupape de sûreté Si le manostat n arrête pas le compre...

Страница 36: ...refroidissement de pointe Le cœur de ce système de refroidissement et un ventilateur Il est tout à fait normal que ce ventilateur souffle une grande quantité d air à travers les trous d aération L expulsion d air indique que le système de refroidissement est en fonction Pompe du compresseur d air non illustrée La pompe comprime l air pour le forcer dans le réservoir d air L air n est pas disponibl...

Страница 37: ... utilisation REMARQUE Utilisez toujours le compresseur d air dans une région bien aérée sans vapeurs d essence ni autres vapeurs combustibles Si le compresseur est utilisé avec un vaporisateur NE PAS placer le compresseur près de la région de vaporisation Avant chaque mise en marche 1 Placez le levier On Auto Off à la position OFF 2 Tirez le bouton du régulateur et tournez le dans le sens contrair...

Страница 38: ...urrait avoir lieu et causer une rupture ou une explosion du réservoir à air 1 Avant de mettre en marche le compresseur tirez sur l anneau de la soupape de sûreté pour vous assurer que la soupape fonctionne librement Si la soupape est coincée ou qu elle ne bouge pas librement elle doit être remplacée par une autre soupape du même type ENTRETIEN Responsabilités du client 1 Vérifier la soupape de sûr...

Страница 39: ...teur est équipé d un dispositif de protection contre les surcharges thermiques avec rétablissement automatique Si le moteur surchauffe pour quelque raison que ce soit le dispositif de protection contre les surcharges arrêtera le moteur Laissez refroidir le moteur Le compresseur redémarrera automatiquement une fois que le moteur est bien refroidi Si le dispositif de protection contre les surcharges...

Страница 40: ... réservoir de la section sur l entretien 2 Débranchez le compresseur d air 3 Retirez l anneau du régulateur et retirez le couvercle de la console 4 Retirez les protecteurs 5 À l aide d une clé réglable desserrez l écrou du tube de sortie au niveau du réservoir d air et de la pompe Éloignez soigneusement le tube de sortie de la soupape de retenue A14841 ENTRETIEN ET RÉGLAGES Tube de sortie Soupape ...

Страница 41: ...vercle de la console et l anneau du régulateur Remplacement du régulateur 1 Laissez s échapper toute la pression du réservoir Voir Vidange du réservoir dans la section Entretien 2 Débranchez l appareil 3 Retirez l anneau du régulateur et retirez le couvercle de la console 4 Avec une clé réglable relâchez l écrou du tube de détente au réservoir d air et au pressostat 5 À l aide d une clé réglable p...

Страница 42: ...pe de sûreté 6 Vidangez l eau du réservoir d air en ouvrant le robinet de vidange situé en bas du réservoir L eau dans le réservoir d air peut condenser Si le réservoir n est pas vidangé l eau corrodera et affaiblira les parois du réservoir d air causant ainsi un risque d éclatement du réservoir 7 Une fois la vidange de l eau terminée fermez le robinet de vidange REMARQUE Si le robinet de vidange ...

Страница 43: ...lution d eau savonneuse Ne Pas Trop Serrer Fuites d air aux raccords Fuites d air à la soupape de décharge du manostat Soupape de décharge défectueuse du manostat Contactez un technicien qualifié Fuites d air au réservoir d air ou aux soudures du réservoir Réservoir d air défectueux Le réservoir d air doit être remplacé Ne tentez pas de réparer les fuites Ne pas percer souder ni modifier autrement...

Страница 44: ...essoires Utilisation prolongée et excessive de l air Le compresseur n est pas assez gros pour la quantité d air requise Trou dans le boyau Soupape de retenue obstruée Fuites d air Filtre d admission d air obstrué Diminuez la quantité d air utilisé Vérifiez les exigences en air de l accessoire Si elles sont plus élevées que la valeur SCFM pi3 min ou la pression produite par le compresseur vous avez...

Страница 45: ... du manostat Vérifiez la rallonge pour s assurer qu elle est de longueur et de calibre approprié Vérifiez les connexions de câblage dans le manostat et la boîte à bornes Retirez et nettoyez ou remplacez la soupape Faire vérifier par un technicien de service qualifié Faire vérifier par un technicien de service qualifié N utilisez pas le compresseur d air dans une région de vaporisation de peinture ...

Страница 46: ...54 FR A14841 NOTES REMARQUE ...

Страница 47: ...55 FR A14841 NOTES REMARQUE ...

Страница 48: ...r repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME Anytime day or night 1 800 469 46...

Отзывы: