4 - ENG

N014212

HAZArD

 

 

 risk OF exPLOsiON Or Fire

WHAT CAN HAPPeN

HOW TO PreveNT iT

• 

It is normal for electrical contacts 

within the motor and pressure 

switch to spark.

• 

Always operate the compressor in a 

well ventilated area free of combus-

tible materials, gasoline, or solvent 

vapors.

• 

If electrical sparks from compressor 

come into contact with flammable 

vapors, they may ignite, causing fire 

or explosion.

• 

If spraying flammable materials, 

locate compressor at least 20 feet 

(6.1 m) away from spray area. An 

additional length of air hose may be 

required.

• 

Store flammable materials in a 

secure location away from com-

pressor.

• 

Restricting any of the compressor 

ventilation openings will cause seri-

ous overheating and could cause 

fire.

• 

Never place objects against or on 

top of compressor.

• 

Operate compressor in an open 

area at least 12" (30.5 cm) away 

from any wall or obstruction that 

would restrict the flow of fresh air to 

the ventilation openings.

• 

Operate compressor in a clean, dry 

well ventilated area. Do not operate 

unit indoors or in any confined area.

• 

Unattended operation of this prod-

uct could result in personal injury 

or property damage. To reduce the 

risk of fire, do not allow the com-

pressor to operate unattended.

• 

Always remain in attendance with 

the product when it is operating.

• 

Always turn off and unplug unit 

when not in use.

HAZArD

 

 RISK TO BREATHING (ASPHYxIATION)

 

WHAT CAN HAPPeN

HOW TO PreveNT iT

• 

The compressed air directly from 

your compressor is not safe for 

breathing. The air stream may 

contain carbon monoxide, toxic 

vapors, or solid particles from the 

air tank. Breathing these contami-

nants can cause serious injury or 

death.

• 

Air obtained directly from the com-

pressor should never be used to 

supply air for human consumption. 

In order to use air produced by this 

compressor for breathing, suitable 

filters and in-line safety equipment 

must be properly installed. In-line 

filters and safety equipment used 

in conjunction with the compres-

sor must be capable of treating air 

to all applicable local and federal 

codes prior to human consump-

tion. 

Содержание 919.15216

Страница 1: ...ation Maintenance Service and Adjustments Troubleshooting Repair Parts Model No 919 152160 CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www sears com craftsman N014212 Rev 0 7 24 08 ...

Страница 2: ... this warranty applies for only ninety days from the date of purchase This warranty gives you specific legal rights and you may have other rights which vary from state to state Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 WARRANTY 2 SPECIFICATION CHART 3 SAFETY GUIDELINES DEFINITIONS 3 IMPORTANT SAFETY INSTRUCTIONS 3 9 GLOSSARY 9 ACCESSORIES 9 duty cycle 9 assembly 10 INSTALLATION 10 1...

Страница 3: ...tion which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property d...

Страница 4: ...on openings Operate compressor in a clean dry well ventilated area Do not operate unit indoors or in any confined area Unattended operation of this prod uct could result in personal injury or property damage To reduce the risk of fire do not allow the com pressor to operate unattended Always remain in attendance with the product when it is operating Always turn off and unplug unit when not in use ...

Страница 5: ... air tank and result in a violent air tank explosion What can happen How to prevent it Failure to properly drain condensed water from air tank causing rust and thinning of the steel air tank Drain air tank daily or after each use If air tank develops a leak replace it immediately with a new air tank or replace the entire compressor Modifications or attempted repairs to the air tank Never drill int...

Страница 6: ...other electrically powered device If it is not used properly it may cause electric shock Never operate the compressor outdoors when it is raining or in wet conditions Never operate compressor with protective covers removed or damaged Repairs attempted by unqualified personnel can result in serious injury or death by electrocution Any electrical wiring or repairs required on this product should be ...

Страница 7: ...ous burns Never touch any exposed metal parts on compressor during or immediately after operation Compressor will remain hot for several minutes after operation Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool HAZARD Risk from Moving Parts What can happen How to prevent it Moving parts such as the pulley fly wheel and belt can cause serious injury i...

Страница 8: ...uip area of operation with a fire extinguisher Do not op er ate machine with miss ing broken or un au tho rized parts HAZARD Risk of Falling What can happen How to prevent it A portable compressor can fall from a table workbench or roof causing damage to the compres sor and could result in serious injury or death to the operator Always operate compressor in a stable secure position to prevent acci...

Страница 9: ...ted equal to or higher than the rating of the air compressor ACCESSORIES This unit is capable of powering the following accessories The accessories are available through the current Power and Hand Tool Catalog or full line Sears stores average duty cycle be maintained that is the air compressor pump should not run more than 30 45 minutes in any given hour continue to use your accessory When the ta...

Страница 10: ... equipped with a cord having a grounding wire with an appropriate grounding plug see following illustrations 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances 2 Make sure the outlet being used has the same configuration as the ...

Страница 11: ...oltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Risk of Opertion Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with speci...

Страница 12: ...tch in the On I position to provide automatic power to the pressure switch and Off O to remove power at the end of each use Pressure Switch not shown The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut in pressure It stops the motor when the air tank pressure reaches the factory set cut out pressure Safety Valve If the pressure switch does ...

Страница 13: ...Open the drain valve counter clockwise fully to permit air to escape and prevent air pressure build up in the air tank during the break in period 4 Move the On Off switch to On position The compressor will start 5 Run the compressor for 15 min utes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 After 15 minutes close the drain valve by turning clockwise The ...

Страница 14: ...ration Risk from noise Air tanks contain high pressure air Keep face and other body parts away from outlet of drain Use ANSI Z87 1 eye protection CAN CSA Z94 3 when draining as debris can be kicked up into face Use ear protection ANSI S12 6 S3 19 hearing protection as air flow noise is loud when draining 1 Set the On Off switch to Off 2 Turn the regulator knob counter clockwise to set the outlet p...

Страница 15: ...tomatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconnect electrical supply to the air compressor bleed tank of pressure and allow the air compressor to cool 6 Apply sealant to the check valve threads Reinstall the check valve turn clockwise 7 Replace hose and new hose clamp 8 Perform the Break in Pro...

Страница 16: ...ou do the following 1 Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary 2 Set the On Off switch to Off and unplug unit 3 Turn the regulator counterclock wise and set the outlet pressure to zero 4 Remove the air tool or accessory 5 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi Release safe...

Страница 17: ... high Contact a Trained Service Technician Air leaks at fittings Tube fittings are not tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks in air tank or at air tank welds Defective air tank Air tank must be replaced Do not repair the leak Risk bursting Do not drill into weld or otherwise modify air tank or it will wea...

Страница 18: ...e regulated pressure under flow conditions while accessory is being used Compressor is not sup plying enough air to operate accessories Prolonged excessive use of air Decrease amount of air usage Compressor is not large enough for air require ment Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Hole in hose ...

Страница 19: ...You should use a time delay fuse Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Extension cord is wrong length or gauge Check the extension cord Loose electrical connections Check wiring connection inside terminal box Faulty motor Have checked by a Trained Service Technician Motor ov...

Страница 20: ...20 ENG N014212 AIR COMPRESSOR DIAGRAM Air Compressor Model Number 919 152160 PARTS SHOWN FOR REFERENCE ONLY ...

Страница 21: ...21 ENG N014212 PARTS LIST Air Compressor Model Number 919 152160 ...

Страница 22: ...22 ENG N014212 PUMP DIAGRAM Air Compressor Model Number 919 152160 ...

Страница 23: ...23 ENG N014212 PARTS LIST Air Compressor Model Number 919 152160 ...

Страница 24: ...42 N0142128 NOTES NOTA ...

Страница 25: ...cional llame al 1 800 827 6655 Servicio de Instalaciones de Sears Para instalaciones profesionales de artefactos para el hogar a cargo de Sears como abridores de puertas de garajes calentadores de agua y otros artefactos grandes del hogar en EE UU llame al 1 800 4 MY HOME Master Protection Agreements Congratulations on making a smart purchase Your new Craftsman product is designed and manufactured...

Страница 26: ...com Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME Anytime day or ni...

Отзывы: