![Craftsman 919.15216 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/craftsman/919-15216/919-15216_owners-manual_68261014.webp)
14 - ENG
N014212
MAiNTeNANCe
Customer Responsibilities
Before
each
use
Daily
or after
each
use
Check Safety Valve
x
Drain Tank
x
Unit cycles
automatically when
power is on. When performing
maintenance, you may be exposed
to voltage sources, compressed air,
or moving parts. Personal injuries
can occur. Before performing any
maintenance or repair, disconnect
power source from the compressor
and bleed off all air pressure.
NOTE:
See
Operation
section for the
location of controls.
To Check Safety Valve
Risk of Bursting.
If the safety valve
does not work properly, over-
pressurization may occur, causing
air tank rupture or an explosion.
Risk from Flying
Objects. Always
wear certified safety equipment:
ANSI Z87.1 eye protection (CAN/CSA
Z94.3) with side shields
1. Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve
is stuck or does not operate
smoothly, it must be replaced with
the same type of valve.
To Drain Tank
Risk of Unsafe
Operation. Risk
from noise. Air tanks contain high
pressure air. Keep face and other
body parts away from outlet of
drain. Use ANSI Z87.1 eye protection
(CAN/CSA Z94.3) when draining as
debris can be kicked up into face.
Use ear protection [(ANsi s12.6
(S3.19)] hearing protection) as air
flow noise is loud when draining.
1. Set the On/Off switch to "Off".
2. Turn the regulator knob counter-
clockwise to set the outlet
pressure to zero.
3. Remove the air tool or accessory.
4. Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately
20 PSI. Release safety valve ring.
5. Drain water from air tank by
opening drain valve on bottom of
tank.
Risk of Bursting.
Water will condense
in the air tank. If not drained, water
will corrode and weaken the air tank
causing a risk of air tank rupture.
How to Start:
1. Set the On/Off switch to "On"
and allow tank pressure to build.
Motor will stop when tank pressure
reaches "cut-out" pressure.
2. Turn regulator knob clockwise to
increase pressure and stop when
desired pressure is reached.
If any unusual
noise or vibration
is noticed, stop the compressor
immediately and have it checked by
a trained service technician.
The compressor is ready for use.
Содержание 919.15216
Страница 20: ...20 ENG N014212 AIR COMPRESSOR DIAGRAM Air Compressor Model Number 919 152160 PARTS SHOWN FOR REFERENCE ONLY ...
Страница 21: ...21 ENG N014212 PARTS LIST Air Compressor Model Number 919 152160 ...
Страница 22: ...22 ENG N014212 PUMP DIAGRAM Air Compressor Model Number 919 152160 ...
Страница 23: ...23 ENG N014212 PARTS LIST Air Compressor Model Number 919 152160 ...
Страница 24: ...42 N0142128 NOTES NOTA ...