For best results and more efficient power, it is recommended that you operate your inflator with your 
VEHICLE’S ENGINE RUNNING, making absolutely sure you are outside or in an open, well-ventilated 
area and NOT INSIDE A CONFINED AREA, SUCH AS A GARAGE as bodily injury or asphyxiation 
resulting in death could occur. 

ALWAYS ALLOW FOR PROPER VENTILATION. 

 Most vehicle 12 Volt 

power outlets will operate with vehicle ignition off; however, some vehicles require that the ignition be 
turned on.

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

Save these instructions 

 

Improper operation or maintenance of this product could result in serious injury and property 
damage.  Read and understand all warnings and operation instructions before using this 
equipment. 
 
 

HAZARD 

 

WARNING:

  

Risk of explosion or fire

 

 

What Could Happen 

How To Prevent It 

It is normal for electrical contacts 

within the motor 

to spark. 

Always 

operate the inflator in a 

well ventilated 

area free of combustible materials, gasoline, or 
solvent vapors.

 

If

 electrical 

sparks 

from inflator 

come into contact with 
flammable vapors, they may 
ignite, causing fire or explosion. 

Store flammable materials in a secure location 
away from inflator. 

Restricting 

any of the 

inflator 

ventilation openings

 will cause 

serious overheating and 

could 

cause fire. 

Never place objects against or on top of inflator.  
Operate inflator

 in an open area 

at least 12 

inches away from

 any 

wall or obstruction 

that 

would restrict the flow of fresh air to the ventilation 
openings.   

Do not operate unit in any confined area. 

Unattended operation 

of this 

product 

could result in personal 

injury or property damage.  To 
reduce the risk of fire, do not 
allow the inflator to operate 
unattended. 

Always remain in attendance 

with the product 

when it is operating.  

Always disconnect power by 

moving on/off switch to the off position and 
unplug the power cord. 

 
 
 
 

 
 
 
 
 
 

 
 
 

3

 

Содержание 75120

Страница 1: ...N Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Brands Management Corporation Hoffman Estates IL 60179 U S A Visit our Craftsman website www craftsman com Safety Guidelines Assembly Operation Maintenance Troubleshooting ...

Страница 2: ...nty coverage details to obtain free replacement visit the web site www craftsman com This warranty does not cover the air needle which is an expendable part that can wear out from normal use within the warranty period This warranty is void if this product is ever used while providing commercial services or if rented to another person This warranty gives you specific legal rights and you may also h...

Страница 3: ...o reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment always wear MSHA NIOSH approved properly fitting face mask or respirator when using such tools When using air tools basic safety precautions should always be followed to reduce the risk of personal injury Use 12 Volt DC only Make sure that your vehicle 12 Volt power outlet is free of an...

Страница 4: ...or electrical contacts within the motor to spark Always operate the inflator in a well ventilated area free of combustible materials gasoline or solvent vapors If electrical sparks from inflator come into contact with flammable vapors they may ignite causing fire or explosion Store flammable materials in a secure location away from inflator Restricting any of the inflator ventilation openings will...

Страница 5: ...tissue damage to exposed skin and can propel dirt chips loose particles and small objects at high speed resulting in property damage or personal injury Always wear ANSI Z87 1 approved safety glasses with side shields when using the inflator Never direct compressed air toward any part of the body or at other people or animals Always turn the inflator off before attempting maintenance or attaching a...

Страница 6: ...tact with you your clothing loose hair or jewelry Never operate the inflator with guards or covers which are damaged or removed Attempting to operate inflator with damaged or missing parts or attempting to repair inflator with protective shrouds removed can expose you to moving parts and can result in serious injury Any repairs required on this product should be preformed by authorized service cen...

Страница 7: ...features of this product Equip area of operation with a fire extinguisher Do not operate machine with missing broken or unauthorized parts HAZARD WARNING Risk of Injury Do not direct air stream at body Disconnect from supply circuitry before replacing fuse SAVE THESE INSTRUCTIONS GLOSSARY Become familiar with these terms before operating the unit CFM Cubic feet per minute SCFM Standard cubic feet ...

Страница 8: ... air mattresses small boats inflatable toys and other items that require large volume of low pressure air ASSEMBLY Contents of Carton To Remove Inflator from Carton 1 Inflator equipped with rubber air hose and pressure gauge PVC Coil Air Hose with built in Screw on valve 1 Inflation Accessory Kit 1 Air Needle 1 Presta Valve Adaptor 1 High Flow Inflator Deflator Adaptor with three nozzles and seal ...

Страница 9: ...le Attaches directly to the screw on valve to inflate sport balls High Flow Inflator Deflator Adaptor Used with inflator deflator nozzles this adaptor attaches directly to the screw on valve to inflate or deflate air mattresses small boats inflatable toys and other items that require a large volume of low pressure air Inflator Deflator Nozzles Used with High Flow Inflator Deflator Adaptor Seal Rin...

Страница 10: ... the pressure gauge on the unit is for general reference only To inflate sports ball air mattress rubber raft etc 1 Remove 12 Volt Direct Drive Inflator from carrying case and place evenly on flat surface 2 Connect the PVC coil air hose to the Inflator by pulling back on the quick connect coupler collar and inserting this on valve located on the end of the 1 foot rubber air hose Push in firmly and...

Страница 11: ...ery large air inlets Insert nozzle thru seal ring as shown 3 The high flow inflator deflator adaptor has an inflation outlet and deflation outlet Attach the nozzle to the preferred outlet NOTE Inflation and Deflation are marked at outlets Inflation Position Deflation Position 4 Insert nozzle into inflatable and start inflator NOTE If inflatable is not getting firm enough place thumb over the defla...

Страница 12: ...ARNING Risk of Unsafe Operation Voltage sources moving parts or compressed air sources are exposed when repairing the inflator Personal injury can occur Unplug the inflator before attempting the repairs PROBLEM CAUSE CORRECTION Motor will not run Blown Fuse Faulty motor 1 Check fuse in end of 12 Volt plug See diagram below 2 Check automobile fuse for 12 Volt receptacle Contact 1 800 874 5771 SPECI...

Страница 13: ... expert advice www managemylife com For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY ...

Отзывы: