background image

HAZARD 

 

WARNING:  Risk of Unsafe Operation 

 

What Could Happen 

How To Prevent It 

Unsafe operation 

of your inflator 

could 

lead to serious injury or death to you 
or others. 

Review and understand 

all instructions 

and 

warnings

 in this manual.  

Become familiar with the operation and 
controls 

of the inflator. 

Keep operating area clear 

of all persons, 

pets and obstacles.   

Keep children away

 from the inflator 

at all 

times. 
Do not operate 

the product 

when fatigued 

or under the influence of alcohol or 
drugs.  Stay alert at all times. 
Never defeat the safety features 

of this 

product. 

Equip area of operation with a fire 
extinguisher. 
Do not operate machine with missing, 
broken, or unauthorized parts. 

 

HAZARD 

 

WARNING: Risk of Injury 

 

 

Do not direct air stream at body. 

 

Disconnect from supply circuitry before replacing fuse. 

 

 

SAVE THESE INSTRUCTIONS 

 

GLOSSARY 

 

Become familiar with these terms 
before operating the unit.   
 

CFM:  

Cubic feet per minute. 

 

SCFM:  

Standard cubic feet per minute; 

a unit of measure of air delivery. 
 

PSIG:  

Pounds per square inch gauge; 

a unit of measure of pressure. 

Code Certification: 

 Products that bear one 

or more of the following marks: UL, CUL, 
ETL, CETL, have been evaluated by OSHA 
certified independent safety laboratories 
and meet the applicable Underwriters 
Laboratories Standards for Safety. 

 

 
 
 
 
 
 
 
 

Содержание 75120

Страница 1: ...N Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Brands Management Corporation Hoffman Estates IL 60179 U S A Visit our Craftsman website www craftsman com Safety Guidelines Assembly Operation Maintenance Troubleshooting ...

Страница 2: ...nty coverage details to obtain free replacement visit the web site www craftsman com This warranty does not cover the air needle which is an expendable part that can wear out from normal use within the warranty period This warranty is void if this product is ever used while providing commercial services or if rented to another person This warranty gives you specific legal rights and you may also h...

Страница 3: ...o reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment always wear MSHA NIOSH approved properly fitting face mask or respirator when using such tools When using air tools basic safety precautions should always be followed to reduce the risk of personal injury Use 12 Volt DC only Make sure that your vehicle 12 Volt power outlet is free of an...

Страница 4: ...or electrical contacts within the motor to spark Always operate the inflator in a well ventilated area free of combustible materials gasoline or solvent vapors If electrical sparks from inflator come into contact with flammable vapors they may ignite causing fire or explosion Store flammable materials in a secure location away from inflator Restricting any of the inflator ventilation openings will...

Страница 5: ...tissue damage to exposed skin and can propel dirt chips loose particles and small objects at high speed resulting in property damage or personal injury Always wear ANSI Z87 1 approved safety glasses with side shields when using the inflator Never direct compressed air toward any part of the body or at other people or animals Always turn the inflator off before attempting maintenance or attaching a...

Страница 6: ...tact with you your clothing loose hair or jewelry Never operate the inflator with guards or covers which are damaged or removed Attempting to operate inflator with damaged or missing parts or attempting to repair inflator with protective shrouds removed can expose you to moving parts and can result in serious injury Any repairs required on this product should be preformed by authorized service cen...

Страница 7: ...features of this product Equip area of operation with a fire extinguisher Do not operate machine with missing broken or unauthorized parts HAZARD WARNING Risk of Injury Do not direct air stream at body Disconnect from supply circuitry before replacing fuse SAVE THESE INSTRUCTIONS GLOSSARY Become familiar with these terms before operating the unit CFM Cubic feet per minute SCFM Standard cubic feet ...

Страница 8: ... air mattresses small boats inflatable toys and other items that require large volume of low pressure air ASSEMBLY Contents of Carton To Remove Inflator from Carton 1 Inflator equipped with rubber air hose and pressure gauge PVC Coil Air Hose with built in Screw on valve 1 Inflation Accessory Kit 1 Air Needle 1 Presta Valve Adaptor 1 High Flow Inflator Deflator Adaptor with three nozzles and seal ...

Страница 9: ...le Attaches directly to the screw on valve to inflate sport balls High Flow Inflator Deflator Adaptor Used with inflator deflator nozzles this adaptor attaches directly to the screw on valve to inflate or deflate air mattresses small boats inflatable toys and other items that require a large volume of low pressure air Inflator Deflator Nozzles Used with High Flow Inflator Deflator Adaptor Seal Rin...

Страница 10: ... the pressure gauge on the unit is for general reference only To inflate sports ball air mattress rubber raft etc 1 Remove 12 Volt Direct Drive Inflator from carrying case and place evenly on flat surface 2 Connect the PVC coil air hose to the Inflator by pulling back on the quick connect coupler collar and inserting this on valve located on the end of the 1 foot rubber air hose Push in firmly and...

Страница 11: ...ery large air inlets Insert nozzle thru seal ring as shown 3 The high flow inflator deflator adaptor has an inflation outlet and deflation outlet Attach the nozzle to the preferred outlet NOTE Inflation and Deflation are marked at outlets Inflation Position Deflation Position 4 Insert nozzle into inflatable and start inflator NOTE If inflatable is not getting firm enough place thumb over the defla...

Страница 12: ...ARNING Risk of Unsafe Operation Voltage sources moving parts or compressed air sources are exposed when repairing the inflator Personal injury can occur Unplug the inflator before attempting the repairs PROBLEM CAUSE CORRECTION Motor will not run Blown Fuse Faulty motor 1 Check fuse in end of 12 Volt plug See diagram below 2 Check automobile fuse for 12 Volt receptacle Contact 1 800 874 5771 SPECI...

Страница 13: ... expert advice www managemylife com For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY ...

Отзывы: