24
25
24
25
To avoid possible injury and damage
to the workpiece, be sure to INSTALL
THE BLADE WITH THE TEETH
POINTING TOWARD THE FRONT OF
TABLE in the direction of the rotation
arrow on the blade guard.
REMOVING THE BLADE (FIG. N, P)
To avoid injury from an accidental
start, make sure the switch is in the
OFF position and the plug is not
connected to the power source outlet.
1. Remove the table insert (1) by
inserting your finger into the
opening (2) and pulling up.
Raise the blade to the maximum
height position by turning the
blade elevation/tilting handwheel
clockwise. (Fig. N)
2. To loosen the arbor nut (3), place
the open-end wrench (8) on the flats
of the saw arbor to keep the arbor
from turning. (Fig. P)
3. Place the box-end wrench (9)
on the arbor nut (3) and turn
counterclockwise. (Fig. P)
4. Remove the arbor nut (3), outer
blade flange (4) and blade (7).
Clean but do not remove the inner
blade flange before reassembling
the blade. (Fig. P)
INSTALLING THE RIVING KNIFE
(FIG. P, Q, R)
● To avoid injury from an accidental
start, make sure the switch is in
the OFF position and the plug
is disconnected from the power
source outlet.
● Never operate this saw without
the riving knife in the correct
position.
1. Remove the table insert.
2. Raise the blade to the maximum
height position by turning the blade
elevation/tilting handwheel (1)
clockwise. (Fig. P)
3. Loosen the blade lock knob (2).
Turn and move the handwheel (1)
to 45° on the bevel scale.
4. Tighten the blade lock knob (2).
WARNING
!
WARNING
!
Fig. P
1
2
Fig. P
3
5
9
8
7
4
WARNING
!