9. Switch Housing Assembly.

10. Testing Your Fan.

It is recommended that you test fan before 
finalizing installation. Restore power from circuit 
box and light switch (if applicable). Test fan speeds 
with the pull chain. Start at the OFF position (no 
blade movement). First pull will set the fan to HI. 
Second pull will set the fan to MEDIUM. Third pull 
will set the fan to LOW. Fourth pull will again set the 
fan to OFF setting (

diagram 1

). If fan does not 

function, please refer to "Troubleshooting" section 
to solve any issues before contacting Customer 
Service.

Turn fan completely off 

before

 moving the reverse 

switch. Set reverse switch to recirculate air 
depending on the season:
 

- LEFT position in summer (

diagram 2

)

 

- RIGHT position in winter (

diagram 3

)

A ceiling fan will allow you to raise your thermostat 
setting in summer and lower your thermostat 
setting in winter without feeling a difference in 
your comfort.

Important

: Reverse switch must be set either 

completely to the LEFT

 or 

completely to the RIGHT

 for 

fan to function. If the reverse switch is set in the 

middle

 position (

diagram 4

), fan will not operate.

Attach pull chain extension supplied or custom pull 
chain extension (sold separately) to the end of the 
pull chain.  

diagram 1

pull chain
extension

reverse switch

diagram 2

diagram 3

diagram 4

motor 
housing

Remove 3 screws from outer edge of switch 
housing plate (

save screws for later use

). 

Remove 1 screw from fitter plate on underside of 
motor and partially loosen the other 2 screws. 
Align slotted holes in center of switch housing 
plate with loosened screws in fitter plate, allowing 
male plug from motor housing to come through 
hole in middle of switch housing plate. Twist 
switch housing plate to lock. Re-insert screw that 
was removed and secure all screws. 

Connect male plug from motor housing to female 
plug from switch housing. Make sure plugs 
connect tightly. 

Align holes in switch housing with holes in switch 
housing plate. Re-insert screws previously 
removed and use a Phillips screwdriver to secure 
all screws.  

switch housing plate

fitter plate

motor housing

switch housing

male plug

female plug

Содержание ZE56

Страница 1: ...g Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 5 Canopy Assembly pg 6 Blade Assembly pg 6 Switch Housing Assembly pg 7 Testing Your Fan pg 7 Troubleshooting pg 8 Parts Replacement pg 8 War...

Страница 2: ...ctrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CETL or CUL Canada or ETL or UL EEUU listed and mar...

Страница 3: ...against parts inventory that all parts have been included page 2 IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety a canopy 1 piece b hanging bracket...

Страница 4: ...iginal outlet box If installing on a vaulted ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the br...

Страница 5: ...ocate canopy cover in hardware pack Slide yoke cover canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with shiny side toward the motor housing Thread safety cab...

Страница 6: ...housing safety cable safety cable loop wood ceiling joist wood screw and washer WARNING Turn off circuit breakers to current fixture from breaker panel and be sure switch is turned to the OFF position...

Страница 7: ...rews and washers in one of the hardware packs Hold blade plate up to blade Be sure to note label on blade indicating THIS SIDE UP and turn blade so that label faces up aligning posts in blade plate wi...

Страница 8: ...pletely to the LEFT or completely to the RIGHT for fan to function If the reverse switch is set in the middle position diagram 4 fan will not operate Attach pull chain extension supplied or custom pul...

Страница 9: ...ill repair or replace at no charge to the original purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR ONLY shipping prepaid to Craftmade...

Отзывы: