5. Fan Assembly. (cont.)
page 5
With the hanging bracket secured to the outlet box and
able to support the fan, you are now ready to hang your fan.
Grab the fan firmly with two hands. Slide downrod through
opening in hanging bracket and let hanging ball rest on the
hanging bracket. Turn the hanging ball slot until it lines up
with the hanging bracket tab.
WARNING
: Failure to align slot in hanging ball with tab in
hanging bracket may result in serious injury or death.
Tip:
Seek the help of another person to hold the stepladder
in place and to help lift the fan up to you once you are set
on the ladder.
Find a secure attachment point (wood ceiling joist highly
recommended) and secure safety cable. It will be necessary
to use a heavy duty wood screw, washer and lock washer
(not supplied) with the safety cable loop. If necessary, adjust
the loop at the end of the safety cable. The loop at the end
of the safety cable should just fit over the threads on the
wood screw. Test safety cable by pulling on loose end with
pliers. If safety cable slips, the loop must be adjusted
tighter. Extra cable slack can be left in ceiling area.
hanging ball slot
hanging bracket tab
motor housing
safety cable
safety cable loop
wood
ceiling
joist
wood screw
and washer
WARNING
: Turn off circuit breakers to current fixture
from breaker panel and be sure switch is turned to
the OFF position.
CAUTION
:
Be sure outlet box is properly grounded and
that a ground wire (
GREEN
or Bare) is present.
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code.
If you are unfamiliar with electrical wiring or if the
house/building wires are different colors than those
referred to in the instructions below, please use a
qualified electrician.
Note
:
Excess lead wire length from the fan can be cut
to the desired length and then stripped.
When downrod is secured in place on the hanging
bracket, electrical wiring can be made as follows:
Connect
BLACK
and
BLUE
wires from fan to
BLACK
wire from ceiling with wire connector provided.
Connect
WHITE
wire from fan to
WHITE
wire from
ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires together from
fan to
BARE
/
GREEN
wire from ceiling with wire
connector provided.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
6. Wiring.
black supply wire
white supply wire
ground
(green or bare)
*
black
black
white
white
blue
ground
(green
or bare)
from ceiling
from fan
This fan is remote control adaptable (remote control