SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel 

before you begin the fan installation or before servicing the fan or installing accessories.

1.         

READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND 

SAVE THESE INSTRUCTIONS

.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and 

ANSI/NFPA 70-1999.  If you are unfamiliar with electrical wiring or if the house/building wires are different 
colors than those referred to in the instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least 

seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips.  The fan should be 
mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or other 
upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 

pounds (16 kilograms).  The outlet box must be supported directly by the building structure.  Use only CETL 
or CUL in Canada or ETL or UL in USA listed outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable 

for Fan Support of 15.9 kg (35 lbs) or less," and use the mounting screws provided with the outlet box.  Most outlet 
boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be 
replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are 

designed to accept only one 12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 
gauge or there is more than one house wire to connect to the corresponding fan lead wires, consult an electrician for 
the proper size wire connectors to use.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be ETL or UL listed 

and marked suitable for use with the model fan you are installing.  Switches must be ETL or UL general use 
switches.  Refer to the instructions packaged with the light kits and switches for proper assembly.

6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into 

the outlet box.  The wires should be spread apart with the grounded conductor and the 
equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device or 

control fan speed with a full range dimmer switch.  [Using a full range dimmer switch to control fan speed will cause a 
loud humming noise from fan.] (

Note

: This fan 

is

 suitable for use with remote control.)

8.        Do not operate the reverse switch until the fan has come to a complete stop.
9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  Do 

not insert objects into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or 

cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth 

will be suitable for most cleaning.

WARNING

:  

This fan MUST be installed with the safety cable provided with the fan. Failure to use the safety cable 

provided may result in personal injury, damage to the fan or damage to other property.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts OTHER than 

those provided with this fan will void the warranty.

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all possible 

conditions and situations that may occur.  It must be understood that common sense and caution are necessary 
factors in the installation and operation of this fan.

Содержание Stonegate STO52

Страница 1: ...Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 5 Canopy Assembly pg 6 Blade Assembly pg 6 Light Kit Assembly pg 7 Testing...

Страница 2: ...ng fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be ETL or UL listed an...

Страница 3: ...hardware packs a b c d f h k g 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do...

Страница 4: ...ture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing f...

Страница 5: ...yoke set screws and nut securely Refer to diagram 2 Slide yoke cover and canopy over downrod Refer to diagram 3 Thread wires through hanging ball then slide hanging ball over downrod the top of the do...

Страница 6: ...CAUTION Be sure outlet box is properly grounded and that a ground wire GREEN or Bare is present Make sure all electrical connections comply with Local Codes or Ordinances and the National Electrical C...

Страница 7: ...label on blade indicating THIS SIDE UP and turn blade so that label faces up Insert 3 decoratvie nuts from UNDERSIDE of blade i e the side that will face the floor making sure to completely insert ea...

Страница 8: ...labeled LIGHT It is recommended that you test fan before finalizing installation Restore power from circuit box and light switch if applicable Test fan speeds with the pull chain labeled FAN Start at...

Страница 9: ...repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to...

Отзывы: