4. Mounting Plate Installation.

ON

OFF

ON

OFF

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to 
the OFF position.

WARNING

: Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING

: When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure 
and can support the full weight of the fan. Ensure outlet 
box is clearly marked "Suitable for Fan Support." If not, it 
must be replaced with an approved outlet box. Failure to 
do so can result in serious injury.

CAUTION

Be sure outlet box is grounded properly and 

that a ground wire (

GREEN

 or bare) is present.

Install mounting plate to outlet box using original 
screws, spring washers and flat washers provided with 
new or original outlet box.* Pull electrical wiring from 
outlet box through center hole in the mounting plate.

Locate screw on outer edge of mounting plate closest 
to the j-hook and remove that screw. Also, remove 
screw on outer edge of mounting plate directly 
opposite the screw that was just removed. Partially 
loosen the other 2 screws.

*

Note

: It is very important that you use the proper 

hardware when installing the mounting plate as this will 
support the fan.

3. Installation Preparation.

This fan can be mounted as a 

flushmount

 on a 

regular (no-slope) ceiling 

only

Downrod 

installations are 

not

 available for this fan.

Installation requires these tools:

Phillips screwdriver, flat-head screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

downrod

installation

flushmount

installation

CANNOT be

installed on

angled or

vaulted ceilings

blade edge

7 feet

(2.13m)

(76cm)

30

inches

12 f

t. - 15 f

t.

12 ft. - 15 ft.

(3.66m - 4.57m)

(3.66m - 4.57m)

To prevent personal injury and damage, ensure that 
the hanging location allows the blades a clearance 
of 7ft. (2.13m) from the floor and 30in. (76cm) from 
any wall or obstruction. 
This fan is suitable for room sizes up to 400 square 
feet (20.9 square meters).

spring washers

flat washers

outlet box screws

mounting plate

Содержание Revello REV52

Страница 1: ...arts Inventory pg 3 Installation Preparation pg 4 Mounting Plate Installation pg 4 Preparation for Wiring pg 5 Wiring pgs 5 6 Fan Assembly pg 6 Blade Assembly pg 7 Light Kit Assembly pgs 7 8 Handheld...

Страница 2: ...until the fan has come to a complete stop Note If using remote control with reverse capability reverse fan blade direction only when on LOW speed 9 Do not insert anything between the fan blades while...

Страница 3: ...ry that all parts have been included 2 Parts Inventory a mounting plate 1 piece b housing ring 1 piece c motor housing 1 piece d wall plate 1 piece e remote control cover 1 piece f faceplate 3 pieces...

Страница 4: ...on outer edge of mounting plate closest to the j hook and remove that screw Also remove screw on outer edge of mounting plate directly opposite the screw that was just removed Partially loosen the oth...

Страница 5: ...sing ring 6 Wiring wiring for receiver white supply wire black supply wire black black white blue blue white from receiver black AC IN L AC IN N white white ground green or bare from fan from receiver...

Страница 6: ...t of wall control Attach wall control to outlet box and secure with screws from original wall switch Attach wall plate included to wall control using 2 screws provided with the wall control wiring for...

Страница 7: ...ck and break Time Saver Washers for blade attachment screws can be set on each screw prior to installing blades Locate 12 blade attachment screws and washers in hardware pack Slide a blade through one...

Страница 8: ...urely Carefully arrange wiring within fitter plate Align slotted holes in LED light kit with loosened screws in fitter plate Twist LED light kit to lock Re insert screw that was previously removed and...

Страница 9: ...art of remote control cover aligning posts in top of remote control cover with post holes in the bottom Refer to diagram 3 NOTE Make sure to align narrower ends of remote control cover before closing...

Страница 10: ...n for up to 5 seconds Test fan speeds with the different fan speed buttons If the wall and or handheld remote control operate s all of the functions of the fan and light battery batteries has have bee...

Страница 11: ...ates where prohibited Problem Fan fails to operate Solutions 1 Check wall switch to fan wall control 2 Check to be sure wall control optional use is wired properly 3 Check to be sure fan is wired prop...