SAFETY TIPS.

page 3

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel before you begin the fan 

installation or before servicing the fan or installing accessories.

  
1.         

READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND SAVE THESE INSTRUCTIONS.

  
CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 70-1999.  If you are 

unfamiliar with electrical wiring or if the house/building wires are different colors than those referred to in the instructions, please use a 
qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least ten (10) feet (3.05 meters) of 

clearance between the floor and the fan blade tips. (

At least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips 

are needed for PRT78

ONLY

). The fan should be mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from 

walls or other upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 50 pounds (22.68 kilograms).  

The box must be supported directly by the building structure.  Use only CUL (Canada) or UL (USA) listed outlet boxes marked "FOR FAN 
SUPPORT."

  

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable for Fan Support of 22.68 kg 

(50 lb) or less," and use the mounting screws provided with the outlet box as well as the two bolt screws and washers included with the fan.  Most 
outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced.  Consult a 
qualified electrician if in doubt.

  

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept only one 12 

gauge house wire and two lead wires from the fan.  If your house wire is larger than 12 gauge or there is more than one house wire to connect to 
the corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.

  
5.         Electrical diagrams are for reference only.  
6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box.  The wires 

should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of serious bodily injury, DO NOT use power tools to assemble any part of the fan, including the blades.

  

WARNING

:  To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device or control fan speed with a full 

range dimmer switch.  [Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan.] 

  
8.        Do not operate the reverse switch until fan has come to a complete stop. [Note: If using remote control with reverse capability, reverse fan 

blade direction only when on LOW speed.]

9.        Do not insert anything between the fan blades while they are rotating.
10.      When operating the fan in a covered patio location, it is possible for high wind gusts to cause the fan to stop briefly.  It will then emit a 

warning beep for 60 seconds and restart at the same setting.  If you wish to restart the fan sooner, you may push the SPEED button 
during the 60-second warning beep.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  Do not insert objects into the 

path of the blades.

  

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.

11.      Do not use water or detergents when cleaning the fan or fan blades.  A dry dust cloth or lightly dampened cloth will be suitable for most 

cleaning.

  

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts OTHER than those provided with this 

fan will void the warranty.

  
WARNING

:  

This fan MUST be installed with the safety cable provided with the fan.  Failure to use the safety cable provided may result in personal 

injury, damage to the fan or damage to other property.

WARNING

: Support cables MUST be used if installing fan in a covered patio. F

ailure to use the support cables provided may result in personal 

injury, damage to the fan or damage to other property.

CAUTION

:  Metal cover for use without light kit will be HOT if light is left on.  To reduce the risk of personal injury, light kit must be OFF.  Do NOT 

connect molex connections if installing metal cover.

CAUTION

:  Do NOT tamper with or attempt to repair LED component of fixture.  The light source is designed for this specific application and 

should not be serviced by untrained personnel. If any servicing is required, call our customer service department.

  
12.       Light kit is d

immable to 10% with select dimmers.

Modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment.  [The equipment 
refers to the remote and/or wall control and/or LED light kit.]

NOTE

:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.  These 

limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and 
can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 
communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures:
* Reorient or relocate the receiving antenna.
* Increase the separation between the equipment and receiver.
* Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
* Consult the dealer or an experienced radio/TV technician for help.
The LED light kit complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this LED light kit may not cause 
harmful interference, (2) this LED light kit must accept any interference received, including interference that may cause undesired operation.

Distributed by: Craftmade, 3901 South 20th Avenue, DFW Airport, TX, 75261; 1-800-486-4892

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and 

situations that may occur.  It must be understood that common sense and caution are necessary factors in the installation and operation of this 
fan.

Содержание Prost PRT102

Страница 1: ...opy Assembly pg 9 Blade Assembly pg 10 Light Kit Assembly pg 11 Handheld Remote Control Assembly pg 12 Automated Learning Process Activating Code pg 13 Remote Wall Control Operation pg 13 Smart Ceilin...

Страница 2: ...d Home app and create account Ensure the fan and receiver are receiving power from the house supply using the remote control to turn the fan and light ON and OFF Open the Bond Home App on your smart d...

Страница 3: ...e for high wind gusts to cause the fan to stop briefly It will then emit a warning beep for 60 seconds and restart at the same setting If you wish to restart the fan sooner you may push the SPEED butt...

Страница 4: ...piece r shade 1 piece s metal cover 1 piece t support cable 3 pieces u support cable anchor 1 piece v hardware packs page 4 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofo...

Страница 5: ...with large bolt screws and washers included in a hardware pack by aligning holes on mounting plate to holes inside outlet box Pull electrical wiring from outlet box through center hole in the mounting...

Страница 6: ...If you wish to install fan in a covered patio remove 6 screws and washers from yoke plate at top of motor housing and set aside Align holes in support cable anchor with holes in yoke plate and re ins...

Страница 7: ...the hanging bracket set crew holes Pull down firmly on the downrod until it sits securely inside the hanging bracket Attach hanging bracket to the top of downrod by inserting set screws previously rem...

Страница 8: ...breaker panel and be sure switch is turned to the OFF position CAUTION Be sure outlet box is properly grounded and that a ground GREEN or Bare wire is present Make sure all electrical connections com...

Страница 9: ...wall control please proceed to Section 7 below to continue with fan installation To install wall control remove existing wall switch Wire one of the wall controls with wire connectors provided as sho...

Страница 10: ...ade plate with fingers first and then tighten screws securely with a Phillips screwdriver Repeat procedure for remaining blades Locate blade arm screws lock washers in hardware pack Place blade arm on...

Страница 11: ...sen the other 2 screws If you wish to use the light kit connect WHITE wire from LED light kit to WHITE wire from motor housing Connect BLACK wire from LED light kit to BLUE or BLACK wire from motor ho...

Страница 12: ...ake sure to align narrower ends of remote control cover before closing Squeeze top and bottom of remote control cover together until you hear a click at each end indicating that the remote control cov...

Страница 13: ...a faceplate almond or white and press firmly onto front of wall control that was previously installed to the outlet box on the wall Refer to diagram 1 Attach black faceplate to front of handheld remot...

Страница 14: ...8 Test the fan functions You have the option to disable the light function if your fan does not have a light 9 Select YES IT WORKS 10 Specific information about your fan Select Location and choose fr...

Страница 15: ...on to solve any issues before contacting Customer Service Fan must be on LOW before setting the fan in reverse Use button to recirculate air depending on the season A ceiling fan will allow you to rai...

Страница 16: ...button in Section 11 page 13 Problem Fan wobbles Solutions 1 Use the balancing kit provided in one of the hardware packs If no blade balancing kit is provided please call Customer Support 1 800 486 4...

Страница 17: ...plaque et support de suspension p 5 6 Montage du ventilateur p 6 8 C blage p 8 9 Montage de la garniture p 9 Assemblage et montage des pales p 10 Assemblage du kit d clairage p 11 Utilisation de la c...

Страница 18: ...us que le ventilateur et le r cepteur soient aliment s par le r seau de l habitation en ALLUMANT et en TEIGNANT le ventilateur et l clairage l aide de la t l commande Lancez l application Bond Home su...

Страница 19: ...s provoquent un arr t momentan du ventilateur Il met alors un signal sonore d avertissement pendant 60 secondes puis red marre r gl comme il l tait avant l arr t Si vous souhaitez red marrer le ventil...

Страница 20: ...llique 1pi ce t cordon de soutien 3 pi ces u ancrage de cordon de soutien 1 pi ce v paquets de quincaillerie page 4 1 D ballage de votre ventilateur Ouvrez l emballage avec pr caution Retirez toutes l...

Страница 21: ...sur solive de planfond en bois avec de gros boulons vis et des rondelles inclus dans le paquet de quincaillerie en alignez les trous dans la plaque de suspension avec les trous l int rieur la bo te d...

Страница 22: ...vercle de la garniture doit tre tourn vers le carter moteur Si vous utilisez un ancrage de cordon de soutien alignez les ouvertures sur le bas du couvercle d trier avec les trous de l ancrage de cordo...

Страница 23: ...il s enclenche fermement dans le support de suspension Fixez l extr mit sup rieure au support de suspension en ins rez les vis de fixation retir es pr c demment dans les trous de vis de fixation du s...

Страница 24: ...nud fil d alimentation blanc fil d alimentation noir 6 Cabl ge AVERTISSEMENT Coupez l alimentation lectrique du luminaire en place au niveau des coupe circuits du panneau lectrique et assurez vous qu...

Страница 25: ...ont n cessaires pour faire fonctionner le ventilateur Si vous ne souhaitez pas utiliser la commande murale veuillez passer la Section 7 pour continuer avec l installation du ventilateur Pour installer...

Страница 26: ...s de fixation des bras de pale rondelles autobloquantes dans un paquet de quincaillerie Placez le bras de pale sur la plaque de moteur en alignant les trous des bras de pales et les tenons sur les tro...

Страница 27: ...age et desserrez partiellement les 2 autres vis Si vous souhaitez utiliser le ventilateur avec kit d clairage raccordez le fil BLANC du carter moteur au fil BLANC du kit d clairage DEL Raccordez le fi...

Страница 28: ...Voir sch ma 3 REMARQUE Assurez vous d aligner les extr mit s plus troites du couvercle de la commande distance avant de refermer Serrez les parties sup rieure et inf rieure du couvercle de la command...

Страница 29: ...ant de la commande murale appuyez fermement Voir sch ma 2 IMPORTANT Les commandes distance portative et murale doivent tre SYNCHRONIS ES avec le ventilateur afin de fonctionner correctement commande m...

Страница 30: ...fonction clairage si votre ventilateur n est pas pourvu d un clairage 9 S lectionnez YES IT WORKS Oui a fonctionne 10 Informations sp cifiques sur votre ventilateur S lectionnez Location Emplacement e...

Страница 31: ...ion avant de contacter le Service Client le La vitesse du ventilateur doit tre sur la vitesse LENTE avant d utiliser LOW vitesse la moins lev e avant d utiliser le bouton fonction d inversion de la di...

Страница 32: ...muniquer avec le service de soutien la client le au 1 800 486 4892 pour en r clamer un 2 V rifiez et assurez vous que la les vis de fixation sur l trier du carter moteur est sont fermement ser e s 3 V...

Страница 33: ...a de montaje y el soporte de montaje P gs 5 6 Ensamblaje del ventilador P gs 6 8 Instalaci n el ctrica P gs 8 9 Colocaci n de la cubierta decorativa P g 9 Colocaci n de las aspas P g 10 Instalaci n de...

Страница 34: ...y el receptor est n recibiendo la corriente del suministro de fuerza el ctrica de la casa usando el control remoto para ENCENDER y APAGAR el ventilador y la luz Abrir la aplicaci n Bond Home en su di...

Страница 35: ...ci n de las aspas s lo cuando el ventilador est en velocidad BAJA 9 No insertar ning n objeto entre las aspas mientras est n rotando 10 Si usa el ventilador en un patio o porche cerrado es posible que...

Страница 36: ...de luz LED 1 unidad r pantalla 1 unidad s cubierta de metal 1 unidad t cable de soporte 3 unidades u ancla para cables de soporte 1 unidad v paquetes de art culos de ferreter a p gina 4 1 Desempaquet...

Страница 37: ...urarse de que los tornillos y las arandelas de resorte de la caja de salida se retiren de la caja de salida existente antes de instalar la placa de montaje Instalar el soporte de montaje en una viga d...

Страница 38: ...os para su uso posterior Deslizar el tubo por la cubierta decorativa la tapa de la cubierta decorativa y la cubierta del cuello Referirse al diagrama 3 Nota se tiene que voltear la tapa de la cubierta...

Страница 39: ...ijaci n en el soporte de montaje Jalar el tubo firmemente hacia abajo hasta que se encaje firmemente dentro del soporte de montaje Fijar el soporte de montaje a la parte superior del tubo insertando l...

Страница 40: ...io cubierto 6 Instalaci n el ctrica ADVERTENCIA apagar los cortacircuitos en el panel de electricidad que suplen corriente a la caja de salida y asegurarse de que el interruptor de luz est APAGADO PRE...

Страница 41: ...lado placa cableado para el control de pared caja de salida control de pared bater a de 12V negro AL ventilador negro ENTRADA CA del cortacircuitos negro AL SUMINISTRO de fuerza FAVOR DE DARSE CUENTA...

Страница 42: ...aspas arandelas de seguridad en uno de los paquetes de art culos de ferreter a Coloque el brazo de para el aspa en la placa del motor alineando los agujeros del brazo para el aspa y las estaquillas co...

Страница 43: ...l juego de luz y aflojar los otros 2 tornillos Si desea utilizar el juego de luz LED conectar el cable BLANCO del juego de luz LED al cable BLANCO del bastidor del motor Conectar el cable NEGRO del ju...

Страница 44: ...ear los extremos m s angostos de la cubierta del control remoto antes de cerrarla Apretar la parte superior e inferior de la cubierta del control remoto hasta que se oiga un clic en cada extremo lo cu...

Страница 45: ...nstal anteriormente en la caja de salida de la pared Referirse al diagrama 1 Fijar la tapa negra a la parte delantera del control remoto de mano apretar la tapa fijamente Referirse al diagrama 2 11 Pr...

Страница 46: ...desactivar la funci n de luz si su ventilador no tiene luz 9 Seleccionar YES IT WORKS s funciona 10 Informaci n espec fica sobre su ventilador Seleccionar Location ubicaci n y elegir una de las opcio...

Страница 47: ...Localizaci n de fallas para resolver cualquier asunto antes de comunicarse con el Servicio al cliente Hay que poner el ventilador en posici n BAJA antes de poner el ventilador en reversa Usar el bot...

Страница 48: ...l ventilador 3 Es posible que no tuvo xito el proceso de aprendizaje entre el ventilador el control remoto y si aplica el control de pared y que no se activ el c digo Desconectar la electricidad y rep...

Отзывы: