7. Canopy Assembly.

6. Wiring.

WARNING:

 Turn off circuit breakers to current fixture 

from breaker panel and be sure operating light switch 
is turned to the OFF position. 

CAUTION

Be sure outlet box is properly grounded and 

that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If 
you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to below, please use a qualified electrician.

Note

Excess lead wire length from the fan can be 

cut to the desired length and then stripped.

When downrod is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK

 and 

BLUE

 wire from fan to 

BLACK

 

wire from ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from 

fan to 

BARE

/

GREEN

 wire from ceiling with wire 

connector provided.

If you intend to control the fan light with a separate 
light switch, connect 

BLUE

 wire from fan to the 

BLACK

 (or 

RED

) supply from the independent switch. 

* Wrap each wire connector separately with electrical 
tape as an extra safety measure.

This fan is remote control adaptable (remote
control sold separately).

black

black

white

white

blue

black supply wire

ground

(green

or bare)

white supply wire

*

from ceiling

from fan

ground 
(green or bare)

Locate 2 screws on underside of hanging bracket 
and remove screw closest to the open end of the 
hanging bracket. Partially loosen the other screw. 
Lift canopy to hanging bracket. Place rounded part 
of slotted hole in canopy over loosened screw in 
hanging bracket and push up. Twist canopy to lock. 
Re-insert screw that was removed and then tighten 
both screws securely. 

screw

canopy

hanging bracket

screw

Содержание PHA52 3 Series

Страница 1: ...f 5 blades fan 17 64 lb 8 kg Table of Contents Safety Tips pg 2 Unpacking Your Fan pg 3 Parts Inventory pg 3 Installation Preparation pg 4 Hanging Bracket Installation pg 4 Fan Assembly pgs 5 7 Wiring...

Страница 2: ...onductor on opposite sides of the outlet box WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device or control fan speed with a full range...

Страница 3: ...ory that all parts have been included 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c downrod and hanging ball with pin and clip 1 piece d yoke cover 1 piece e motor housing 1 piece f s...

Страница 4: ...t fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove exist...

Страница 5: ...t and then tighten screws securely with a Phillips screwdriver Repeat procedure for each remaining blade WARNING To reduce the risk of serious bodily injury DO NOT use power tools to assemble the blad...

Страница 6: ...clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nuts securely Refer to diagram 2 Slide yoke...

Страница 7: ...ded and secure safety cable It will be necessary to use a heavy duty wood screw washer and lock washer not supplied with the safety cable loop If necessary adjust the loop at the end of the safety cab...

Страница 8: ...nnect WHITE wire from fan to WHITE wire from ceiling with wire connector provided Connect all GROUND GREEN wires together from fan to BARE GREEN wire from ceiling with wire connector provided If you i...

Страница 9: ...an to the OFF setting Test light with the pull chain labeled LIGHT diagram 1 If fan and or light do does not function please refer to Troubleshooting section to solve any issues before contacting Cust...

Страница 10: ...in material or workmanship Contact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade We will repair or ship you a replacement fan and w...

Страница 11: ...ubierta decorativa P g 8 Colocaci n del juego de luz P g 9 Verificaci n del funcionamiento del ventilador P g 9 Localizaci n de fallas P g 10 Piezas de repuesto P g 10 Garant a P g 10 peso neto del ve...

Страница 12: ...es empalmados deben ser volteados para arriba y colocados cuidadosamente dentro de la caja de salida Los alambres se deben de separar con el conductor a tierra a un lado y el conductor a tierra del eq...

Страница 13: ...ificar que se incluyeron todas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a cubierta decorativa 1 unidad b sop...

Страница 14: ...existente asegurarse de que la caja de salida est firmemente conectada a la estructura del edificio y que sea capaz de sostener el peso total del ventilador Asegurarse de que la caja de salida indiqu...

Страница 15: ...destornillador de estrella Phillips Repetir el procedimiento con las dem s aspas ADVERTENCIA para reducir el riesgo de lesiones corporales graves NO utilice herramientas el ctricas para ensamblar las...

Страница 16: ...a que se quitaron anteriormente Apretar los tornillos de fijaci n del cuello y la tuerca completamente Referirse al diagrama 2 Deslizar la cubierta del cuello y la cubierta decorativa por el tubo Refe...

Страница 17: ...rabajos pesados arandela y arandela de seguridad no provistos en el bucle del cable de seguridad Si es necesario ajuste el bucle en el extremo del cable de seguridad El bucle en el extremo del cable d...

Страница 18: ...e provisto Conectar todos los CONDUCTORES A TIERRA VERDES del ventilador al cable PELADO VERDE del techo con un conector para cable provisto Si usted piensa controlar la luz del ventilador con un inte...

Страница 19: ...ilador en marcha MEDIA El tercer tir n bajar el ventilador a marcha BAJA Con el cuarto tir n se APAGAR el ventilador de nuevo Poner a prueba la luz jalando la cadena de encendido de en medio diagrama...

Страница 20: ...os los gastos incurridos en sacar reinstalar y enviar el producto para reparaci n Esta garant a no se aplica cuando el ventilador tenga da os por abuso mec nico f sico el ctrico o por agua resultando...

Отзывы: